(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

DI10570 Digital Anemometer

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:DI10570
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Vane type probe including temperature sensor (either 1" or 2 3/4" heads available)
The DI10570 is Supplied With
  • Vane type probe including temperature sensor (either 1" or 2 3/4" heads available)
  • 3-12" extension rods
  • 1-9" flexible rod
  • RS232 adapter cable
  • Carrying case
 
Features
  • Very high accuracy
  • Display of air velocity in FPM or M/S
  • Display of temperature in ¡ÆF or ¡ÆC
  • Memory circuit for maximum, minimum and average
  • Measuring time, every 2 seconds
  • Average calculated over 16 seconds
  • Maximum and minimum over current measuring session
  • Data acquisition for up to 1,000 double measurements
  • Maximum and minimum over acquired values
  • Serial output through standard RS232C data link
  • Automatic display and battery test
  • User friendly key pad for simple operation
 
SPECIFICATIONS

Combination air-flow/temp. Probes

Air Flow Range
2 3/4" Probe 40 to 7800 fpm (0.2 to 40.0 m/s)
1" Probe 60 to 6800 fpm (0.3 to 35.0 m/s)
Air Flow Accuracy
2 3/4" Probe 1% of reading, ¡¾1 digit.
1" Probe 1% of reading, ¡¾1 digit
Air Flow Resolution 1 fpm or 0.01 m/s
Temperature Range
(for both probe heads) -22¡ÆF to 212¡ÆF (-30¡ÆC to 100¡ÆC)
Temperature Accuracy 0.2% of reading, ¡¾1 digit
Temperature Resolution 0.2¡ÆF/0.1¡ÆC
Temperature Probe Range -100¡ÆF to 575¡ÆF (-100¡ÆC to 300¡ÆC)
Temperature Probe Accuracy 0.2% of reading, ¡¾1 digit
Temperature Probe Resolution 0.2¡ÆF/0.1¡ÆC
Temperature Probe Sensor Platinum resistance
Display 1/2" LCD, 9999 digits
Data Acquisition Storage capacity up to 1000 double measurements air flow and temperature
Data Link Standard RS232C including handshake signals CTS and RTS
Baud Rate 1200 standard. Other baud rates available between 300 and 2400.
Operating Temperature
Instrument 32¡ÆF to 125¡ÆF (0¡ÆC to 50¡ÆC)
Probe heads 22¡ÆF to 212¡ÆF (-30¡ÆC to 100¡ÆC)
Power Supply 9 volt battery
Battery Life Approximately 30 hours
Dimensions
Instrument 5.9" x 3.2" x 1.2" (150 x 80 x 30 mm)
Probe 100—1" (25.4 mm)
Options Rechargeable battery and charger. Analog output for air flow and temperature 0 volt at low end of range, 2 volt at high end of range. Other ranges available.

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
DI10570   DTA4000/APT275   DIGITAL ANEMOMETER / THERMOMETER / DATA LOGGER W/2.75 HD DTA4000   Yes   1,890,000

 

DI105701   DTA4000 W/APT275   DIGITAL ANEMOMETER / THERMOMETER / DATA LOGGER DTA4000 W/APT275& CG-3   Yes   1,890,000

 

DI10579   IMP-2600   OPTIONAL OPTIONAL PRINTER 70V AC FOR Digital Anemometer / Thermometer / Dataloggers   Yes   594,000

 

DI14   APT100   OPTIONAL 1" HEAD FOR DTA4000 FOR Digital Anemometer / Thermometer / Dataloggers   Yes   918,000

 

DI12   APT275   OPTIONAL 2.75" HEAD FOR DTA4000 FOR Digital Anemometer / Thermometer / Dataloggers   Yes   918,000

 

DI105052   3831   OPTIONAL 5' EXTENSION CABLE FOR DTA4000P/N 3831 FOR Digital Anemometer / Thermometer / Dataloggers   Yes   32,400