(주)코린스

분류 검색

현재위치 : Home > > >

 
이전 큰 이미지 다음

AL13503 Balometer Kit with 2*2 hood

제조사 : DAVIS
제품번호:AL13503
판매가격  : 원
포인트 : 점
수량 :
  PLUS   MINUS   개
■ 회원가입을 하시면 할인된가격을 보실수 있습니다.
■ 모든가격은부가세별도 입니다.
■ 회원이 되시면 가격변동정보, 신제품, 특판제품, 기술정보등 다양한
뉴스정보를 보내드립니다.
■ 30만원미만은 택배비 3,000원(착불)입니다.
■ 카드결재시 세금계산서 발행 불가합니다.
■ 배송은 평균 2~3일정도 예상됩니다.

상세페이지를 마이피플로 보내기 - 웹용 상세페이지를 twitter로 보내기 상세페이지를 facebook으로 보내기 상세페이지를 Me2Day로 보내기

Unique analog gauge with readings in four ranges: 0 to 250 CFM, 200 to 500 CFM, 400 to 1000 CFM etc..
Balometer pays for itself
In just three months your Balometer can save you up to 40 percent of your time on every air flow measurement job. It only takes one person to operate the Balometer, while conventional air flow measuring is often done with two. With the Balometer you can get direct CFM readings. This eliminates the need for calculations and K factors and saves even more of your valuable time. You can take more readings more often and balance air flow for maximum energy efficiency and energy dollar savings No special training or skills are required to operate the Balometer.

Here’s how the Balometer works
The blue hood fits over grilles or diffusers and channels air flow through a manifold to a specially designed base. Sixteen areas of equal size in the base sense air flow, and the reading is displayed directly in CFM. Regardless of the air pattern, you are assured of accurate readings. The Alnor Velometer® is the performance-proven heart of the Balometer. It is factory calibrated for readings between 0 and 2000 CFM. The Velometer’s mirrored anti-parallax scale improves the accuracy of observed readings by eliminating the double image you may experience with conventional scales. The Balometer has a unique range selector for accurate readings in both supply and exhaust air flow. You can select from four ranges: 0-250, 200-500, 400-1000 and 800-2000 CFM. The lowest range (0-250) is especially valuable in today’s critical low air flow systems. Interchangeable blue hoods match standard diffuser openings to fit your particular application.

 
Features
  • Unique analog gauge with readings in four ranges: 0 to 250 CFM, 200 to 500 CFM, 400 to 1000 CFM and 800 to 2000 CFM.
 
SPECIFICATIONS

Accuracy

3% full scale range
Supply and Exhaust Ranges CFM 0 to 250, 200 to 500, 400 to 1000, and 800 to 2000
Standard Hood Openings 16" x 16", 2' x 2', 2' x 4', 1' x 5', and 3' x 3' (406 x 406 mm, 610 x 610 mm, 610 x 1220 mm, 305 x 1220 mm, 305 x 1525 mm, and 915 x 914 mm)
Overall Dimensions Height 40"; base 17" x 17"; width and depth—variable, see standard hood openings. (Height 1017mm; base 432 x 432mm; width and depth—variable, see standard hood openings)
Shipping Dimensions 29" x 14" x 25" (737 x 356 x 635 mm)
Operating Weight With 2' x 2' Hood 9.8 lbs. (4.5 Kg)
Shipping Weight 39 lbs. (17.7kg)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AL13503   6461CFM   ALNOR BALOMETER KIT WITH 2' X 2' HOOD   Yes   4,633,200

 

Includes carrying case 
AL13502   6463CFM   ALNOR BALOMETER KIT WITH 2' X 2', 1' X 4', 2' X 4' HOODS   Yes   5,454,000 
Includes carrying case 
AL13501   6465CFM   ALNOR BALOMETER KIT WITH 2' X 2', 1' X 4', 2' X 4', 3' X 3', AND 1' X 5' HOODS   Yes   6,274,800

 

Includes carrying case