TSI¡¯s DP-Calc¢â Micromanometers allow you to easily make HVAC pressure measurements.
TSI¡¯s DP-Calc¢â Micromanometers allow you to easily make HVAC pressure measurements. The DP-Calc measures static, total, and velocity pressures as well as pressure drops across filters, coils, fans, and diffusers. The microprocessor-based DP-Calc uses the latest electronic pressure transducer technology, eliminating sensitivity due to the orientation of the meter. Each model of the DP-Calc combines a lightweight and durable design with an easy to read display.
 
Model 8702/8705 Features
  • Zeroing function quickly resets instrument zero to ensure accurate measurements
  • Calculates and displays a velocity reading when using a Pitot tube
  • Variable time constant modes available for a steady display when measuring fluctuating flows
  • Sampling function takes a sample and stores the current reading
  • Optional portable printer provides hard copy documentation of your measurements
  • NIST* traceable calibration certificate
 
Additional Features of Model 8705
  • Data logging ability allows user to log 1000 data points with a time and date stamp
  • Data can be reviewed on-screen, printed, and downloaded to your computer spreadsheet program
  • TSI downloading software permits easy transfer of data to a computer
  • Statistics function displays average, maximum and minimum values, and the number of recorded samples
  • Automatic conversion between actual and standard velocity readings
  • Flowrate feature allows for simple and quick calculations of volumetric flowrate by simply inputting the duct shape and size
  • K factor function provides flexibility for measuring flowrates in various applications
 
SPECIFICATIONS

Pressure

Range  -5 to +15 in. H2O (-1245 to 3735 Pa, -9.3 to 28.0 mm Hg,)
Accuracy ¡¾1% of reading ¡¾0.005 in. H2O
 (¡¾1% of reading ¡¾1 Pa)
 (¡¾1% of reading ¡¾0.01 mm Hg)
Resolution
  (TS444561 only) 0.001 in. H2O (1 Pa, 0.01 mm Hg)
  (TS444562 only) 0.0005 in. H2O (0.1 Pa, 0.001 mm Hg)
Velocity
Range 250 ft/min - 15,500 ft/min (1.27 m/s to 78.7 m/s)
Accuracy ¡¾1.5 % at 2,000 ft/min (10.16 m/s)
Operating Range 32 to 158¡ÆF (0 to 70¡ÆC)
Averaging Capability
(TS444561 only)
Up to 255 values each of pressure and velocity
Flow Rate
(TS444562 only)
Up to 9,999,000 CFM, m3/h, l/s
K Factor range  0.01 to 2
Logging Capability
(TS444562 only)
  Up to 1,000 samples and 500 test id's

FEATURES
 

TS444561

TS444562
Differential Pressure
Static Pressure
Velocity
Volumetric Flowrate
Calculate Average
Determines Min/Max
Variable Time Constant
Density Correction
K Factor
Data Logging
Data Dowloading Software
Printer Output
NIST Calibration Certificate

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TS444561   8702   DP-CALC MICROMANOMETER   Yes   1,134,000 
TS444562   8705   DP-CALC MICROMANOMETER KIT (INCLUDES DATALOGGING)   Yes   1,609,200