(주)코린스

분류 검색

현재위치 : Home >

 
이전 큰 이미지 다음

C1700 비접촉식 휴대형 열류계

판매가격 : 전화문의
■ 회원가입을 하시면 할인된가격을 보실수 있습니다.
■ 모든가격은부가세별도 입니다.
■ 회원이 되시면 가격변동정보, 신제품, 특판제품, 기술정보등 다양한
뉴스정보를 보내드립니다.
■ 30만원미만은 택배비 3,000원(착불)입니다.
■ 카드결재시 세금계산서 발행 불가합니다.
■ 배송은 평균 2~3일정도 예상됩니다.

상세페이지를 마이피플로 보내기 - 웹용 상세페이지를 twitter로 보내기 상세페이지를 facebook으로 보내기 상세페이지를 Me2Day로 보내기

C-1700 Series ThermoFlow Thermometer

Measure Temperature and Net Heat Flow Without Contact

The C-1700 Series ThermoFlow Thermometers are self-contained, battery-operated devices designed to measure heat loss ( or gain) through walls and windows without physical contact. The Model C-1700F displays temperature in degrees F and net heat flow in BTU/(sq.ft-hr). A metric version, Model C-1700C, measures temperature in degrees C and net heat flow in Watts/sq. meter.

p_C-1700_series.JPG (12807 bytes)


These portable, low cost, accurate instruments are a significant breakthrough in non-contact detection. Designed for insulation instaalue. Preventive maintenance is improved through early detection of defects in insulation of pipes, furnaces, walls, ducting and by locating hot spots in gears, bearings, electrical junction boxes, and heating/cooling coils.llers, inspectors, energy auditors and plant maintenance engineers, these instruments rapidly and accurately measure the critical perameters needed to determine R-Value or U-V

Features

  • Low cost, easy to use.
  • Non-contact measurement of Heat Flow in BTU's or Watts and Temperature in 캟 or 캜
  • Net Heat Flow includes convective flow
  • One second response time
  • Powered by internal 9-volt battery


How the ThermoFlow Works:

The C-1700 Series has been designed to measure building materials such as paper, plaster, ceramic, stone, concrete or glass, that have emmisivities in excess of 90%. An accurate surface temperature reading is obtained by simply aiming the instrument at the surface to be measured. The diameter of the measured area is approximately 1/3 of the distance from the object.

Net Heat Flow Measurement:

Net Heat Flow is measured by switching the instrument to the heat flow position and aiming the product at the wall or surface which represents the internal temperature of the building The C-1700 is then "zeroed," using the zero adjust control. Net Heat Flow in BTU (or Watts) is then displayed when the instrument is aimed at an exterior wall or window.

Typical Applications

Energy Conservation:

Scanning insulation for voids, location of air infiltration, measuring furnace walls and ducting, locating faulty pipe insulation, R-Value (U-Value) estimation.

 

Preventive Maintenance:

Location of overloaded electrical circuits, breakers, or fuses; steam trap evaluation, motor and bearing overheating. Moisture damage on roofs can also be detected.


Accessories

C-WAND - Used to support the unit at present distance from the target.
C-STAND - Mounts the handheld probe for stationary applications requiring continuous measurement.
C-CASE - Vinyl carrying case with belt loop.