The ATE-100 Handheld Pressure Calibrator measures pressure, flow, vacuum, leak, current, voltage and change-of-state for switch testing.
Each system consists of a base unit and one or two Quick-Select¢â pressure modules with pressure ranges from 0.25 inches H2O to 7500 psi. Modules can be interchanged quickly and easily without the use of tools. A standard RS-232 port allows for computer interfacing. |
|
Features |
- Interchangeable pressure and temperature modules
- Pressure measurement accuracies of ¡¾.05, .10 or .25%
- Pressure ranges from 0.25" H2O to 10,000 psi
- Supports most standard RTD probes
- Data-logging and cert generation available
- Includes two 9V batteries, test leads, AC adapter and soft carrying case
|
| |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
AS10010 |
|
ATE-1-B |
|
PRESSURE CALIBRATOR W/DATALOG & HI/LO RELAYS ATE-1-B*MODULE* |
|
Yes |
|
2,797,200 |
AS10011 |
|
ATE KIT-1A |
|
OPTIONAL SOFT CASE & AC ADPTORFOR ATE-1-B OPTION ATE KIT-1A |
|
Yes |
|
291,600 |
AS10012 |
|
ATE KIT1B |
|
ATE-1-B OPTIONAL HARD CARRYINGCASE & AC ADAPTOR ATE KIT1B |
|
Yes |
|
356,400 |
AS10013 |
|
ATE-1-B EXT TEMP OP |
|
ATE-1-B OPTIONAL EXTENDED TEMPOPERATION -4-120 DEG F |
|
Yes |
|
270,000 |
AS10014 |
|
DIFF. PRESS FIRMWARE |
|
ATE-1-B OPTI0NAL DUAL SENSOR DIFFERENTIAL PRESS. FIRMWARE* |
|
Yes |
|
Call 031-777-1588 |
AS10021 |
|
AQS-1 .25, .5 1"H2O |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULES .06% ACCUR * |
|
Yes |
|
2,268,000 |
Differential Ranges: 0.25, 0.5 or 1.0 inches H2O. Please specify¡¡ |
AS10022 |
|
AQS-1 .25 .5 1"H2O |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULES .10% ACCUR. * |
|
Yes |
|
1,890,000 |
Differential Ranges: 0.25, 0.5 or 1.0 inches H2O. Please specify¡¡ |
AS10024 |
|
AQS-1 .06% PRESSMOD |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULE .06% ACCUR. * |
|
Yes |
|
1,771,200 |
Differential Ranges; 2.0, 3.0, 5.0, 10.0, 15.0, 100, 150 or 200 inches H2O. Please specify¡¡ |
AS10025 |
|
AQS-1 .10% PRESS MOD |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULE .10% ACCUR. * |
|
Yes |
|
1,501,200 |
Differential Ranges; 2.0, 3.0, 5.0, 10.0, 15.0, 100, 150 or 200 inches H2O. Please specify¡¡ |
AS10027 |
|
AQS-1 .06% COMP. |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULE .06% ACCUR. * |
|
Yes |
|
2,322,000 |
Compound Ranges: ¡¾0.125, ¡¾0.25 or ¡¾0.5 H2O Please specify¡¡ |
AS10028 |
|
AQS-1 .10% COMPOUND |
|
AQS-1 LOW PRESS. QUICK SELECT MODULE .10%ACC.COMPOUND RANGE* |
|
Yes |
|
1,941,840 |
Compound Ranges: ¡¾0.125, ¡¾0.25 or ¡¾0.5 H2O Please specify¡¡ |
AS10030 |
|
AQS-1 .06% COMPOUND |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULE .06% ACCUR. * |
|
Yes |
|
1,890,000 |
Compound Ranges: ¡¾1.0, ¡¾1.5, ¡¾2.5, ¡¾5.0, ¡¾7.5, ¡¾12.5, ¡¾25.0, ¡¾50.0 or ¡¾100 H2O Please specify¡¡ |
AS10031 |
|
AQS-1 .10% COMPOUND |
|
AQS-1 LOW PRESS. QUICK SELECT PRESSURE MODULES .10% ACCUR. * |
|
Yes |
|
1,630,800 |
Compound Ranges: ¡¾1.0, ¡¾1.5, ¡¾2.5, ¡¾5.0, ¡¾7.5, ¡¾12.5, ¡¾25.0, ¡¾50.0 or ¡¾100 H2O Please specify¡¡ |
AS10033 |
|
AQS-2 .05% 5-300PSIG |
|
AQS-2 QUICK SELECT PRESSURE MODULE .05% ACCURACY *RANGE* |
|
Yes |
|
1,674,000 |
Pressure Ranges: 5,10,15,30,50,60,100, 150, 200, 250 or 300 psi Please specify¡¡ |
AS10034 |
|
AQS-2 .10% 5-300PSIG |
|
AQS-2 QUICK SELECT PRESSURE MODULES .10% ACCURACY *RANGE* |
|
Yes |
|
1,501,200 |
Pressure Ranges: 5,10,15,30,50,60,100, 150, 200, 250 or 300 psi Please specify¡¡ |
AS10035 |
|
AQS-2 .025%5-300PSIG |
|
AQS-2 QUICK SELECT PRESSURE MODULE .025% ACC *RANGE* |
|
Yes |
|
1,825,200 |
Pressure Ranges: 5,10,15,30,50,60,100, 150, 200, 250 or 300 psi Please specify¡¡ |
AS10036 |
|
AQS-2 .05% 500-7500# |
|
AQS-2 QUICK SELECT PRESSURE MODULE .05% ACCURACY *RANGE* |
|
Yes |
|
1,933,200 |
Pressure Ranges: 500, 600, 1000, 1500, 2000, 2500, 3000, 5000, 6000 or 7500 psi Please specify¡¡ |
AS10037 |
|
AQS-2 .10% 500-7500# |
|
AQS-2 QUICK SELECT PRESSURE MODULE .10% ACCURACY *RANGE* |
|
Yes |
|
1,825,200 |
Pressure Ranges: 500, 600, 1000, 1500, 2000, 2500, 3000, 5000, 6000 or 7500 psi Please specify¡¡ |
AS10038 |
|
AQS-2 .025%500-7500# |
|
AQS-2 QUICK SELECT PRESSURE MODULE .025% ACCURACY *RANGE* |
|
Yes |
|
2,062,800 |
Pressure Ranges: 500, 600, 1000, 1500, 2000, 2500, 3000, 5000, 6000 or 7500 psi Please specify¡¡ |
AS10040 |
|
AQS-2 .05% 5-15#VAC |
|
AQS-2 QUICK SELECT PRESSURE MODULE .05% ACC. ***PSIV |
|
Yes |
|
1,868,400 |
Vacuum Ranges: 5, 10 or 15 psi Please specify¡¡ |
AS10041 |
|
AQS-2 .10% 5-15#VAC |
|
AQS-2 QUICK SELECT PRESSURE MODULE .10% ACC. ***PSIV |
|
Yes |
|
1,674,000 |
Vacuum Ranges: 5, 10 or 15 psi Please specify¡¡ |
AS10042 |
|
AQS-2 .025%5-15#VAC |
|
AQS-2 QUICK SELECT PRESSURE MODULE .025% ACC ***PSIV |
|
Yes |
|
1,933,200 |
Vacuum Ranges: 5, 10 or 15 psi Please specify¡¡ |
AS10043 |
|
AQS-2 .05% COMPOUND |
|
AQS-2 QUICK SELECT PRESSURE MODULE .05% ACCURACY *RANGE* |
|
Yes |
|
1,868,400 |
Compound Ranges: -5/+5, -10/+10, -15/+15, -15/+30 or -15/+60 psi Please specify¡¡ |
AS10044 |
|
AQS-2 .10% COMPOUND |
|
AQS-2 QUICK SELECT PRESSURE MODULE .10% ACCURACY *RANGE* |
|
Yes |
|
1,717,200 |
Compound Ranges: -5/+5, -10/+10, -15/+15, -15/+30 or -15/+60 psi Please specify¡¡ |
AS10045 |
|
AQS-2 .025%COMPOUND |
|
AQS-2 QUICK SELECT PRESSURE MODULE .025% ACCURACY *RANGE* |
|
Yes |
|
1,933,200 |
Compound Ranges: -5/+5, -10/+10, -15/+15, -15/+30 or -15/+60 psi Please specify¡¡ |
AS310 |
|
PPT-RT1 |
|
RTD PROBE FOR Pt100, Ni 120, Cu 10 |
|
Yes |
|
982,800 |
AS315 |
|
840X010-06 |
|
RTD PROBE-6" LGTH, HANDLE, 5' CABALE (0.25) |
|
Yes |
|
637,200 |
AS10047 |
|
316SS ISOLATION SNSR |
|
OPTIONAL OPTIONAL STAINLESS STEEL ISOLATION SENSOR (AVAIL FROM 10-300 psi) FOR Handheld Pressure Calibrator |
|
Yes |
|
248,400 | | |