SPECIFICATIONS
| 
| Features  |  
| 
Built-in pressure/vacuum hand pump, wih vernier and bleed valve 
Pressure measurement to 0.05% of full span, using and internal pressure sensor 
Pressure measurement to 10,000 psi/700 bar using any of the Fluke-700Pxx pressure Modules 
Wide range of selectable measurement units for pressure 
Current measurement with 0.025% accuracy and 0.001 mA resolution 
24 volt loop power supply 
Min-Max Hold functions 
Simple, push-button user interface 
Rugged - Ideal for field use  |  
|  |  |  
| Compact and lightweight | 210 mm L x 83 mm W x 62 mm D |  
| (8.25 in. L x 3.27 in. W x 2.44 in. D) |  
| Operating Temperature | -10¡ÆC to 55¡ÆC |  
| Maximum voltage | 30 volts |  
| Non-operating temperature | -40¡ÆC to 60¡ÆC |  
| Operating temperature | -10¡ÆC to 55¡ÆC |  
| Relative humidity | 95% (10¡ÆC to 30¡ÆC); 75% (30¡ÆC to 40¡ÆC); 45% (40¡ÆC to 50¡ÆC); 35% (50¡ÆC to 55¡ÆC) |  
| Operating altitude | 3,000m max |  
| Shock | 1 m drop test |  
| Vibration | Random, 2g, 5-500 Hz |  
| Safety | CSA C22.2 No. 1010.1:1992 |  
| EMC | EN50082-1:1992 and EN55022:1994; Class B |  
| Size/Weight | 210 mm L x 83 mm W x 62 mm D |  
| (8.25in. L x 3.27in. W x 2.44in. D); 737 g (26 oz) |  
| Power | Two 9V ANSI/NEDA 1604A or IEC 6LR619V alkaline batteries |  
| Battery Life | 4 to 20 hours, typical, depending on functions used |  
| Warranty | Three years (one year on pressure pump) |  
 
| CAT NO. |  | MODEL |  | DEscRIPTION |  | AVAIL |  | PRICE |  
| FL71830 |  | 71830 |  | PRESSURE CALIBRATOR 30 PSIG |  | Yes |  | 3,661,200 |  
| FL718100 |  | 718-100 |  | PRESSURE CALIBRATOR 100 PSIG |  | Yes |  | 3,661,200 |  
| FL700HTP |  | FLUKE-700HTP |  | OPTIONAL HYDRAULIC TEST PUMP FOR USE W/FL700/710 SERIES FOR 718 Pressure Calibrator |  | Yes |  | 1,833,840   |  
| FL700PTP |  | 700PTP |  | OPTIONAL PNEUMATIC TEST PUMP FOR USE W/710/740 SERIES FOR 718 Pressure Calibrator |  | Yes |  | 1,069,200   |  
| FL700IV |  | 700IV |  | OPTIONAL CURRENT SHUNT FOR 718 Pressure Calibrator |  | Yes |  | 451,440 |  
| FL700P01 |  | FLUKE-700P01 |  | OPTIONAL PRESSURE MODULE, 0-10 IN. H2O DIFF. FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200   |  
| FL700P02 |  | FLUKE-700P02 |  | OPTIONAL PRESSURE MODULE, 0-1PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P03 |  | FLUKE-700P03 |  | OPTIONAL PRESSURE MODULE, 0-5 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P04 |  | FLUKE-700P04 |  | OPTIONAL PRESSURE MODULE, 0-15 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P05 |  | FLUKE-700P05 |  | OPTIONAL PRESSURE MODULE, 0-30 PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P06 |  | FLUKE-700P06 |  | OPTIONAL PRESSURE MODULE, 0-100 PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P07 |  | FLUKE-700P07 |  | OPTIONAL PRESSURE MODULE, 0-500 PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P08 |  | FLUKE-700P08 |  | OPTIONAL PRESSURE MODULE, 0-1000 PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200   |  
| FL700P09 |  | FLUKE-700P09 |  | OPTIONAL PRESSURE MODULE, 1500 PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P22 |  | FLUKE-700P22 |  | OPTIONAL PRESSURE MODULE, 0-1 PSID, WET FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700P23 |  | FLUKE-700P23 |  | OPTIONAL PRESSURE MODULE, 0-5 PSID, WET FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200   |  
| FL700P24 |  | FLUKE-700P24 |  | OPTIONAL PRESSURE MODULE, 0-15PSID, WET FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200   |  
| FL700P29 |  | FLUKE-700P29 |  | OPTIONAL PRESSURE MODULE, 3000PSIG, WET FOR 718 Pressure Calibrator |  | Yes |  | 3,661,200   |  
| FL700P30 |  | FLUKE-700P30 |  | OPTIONAL PRESSURE MODULE, 5000PSIG, WET FOR 718 Pressure Calibrator |  | Yes |  | 3,661,200   |  
| FL700P31 |  | FLUKE-700P31 |  | OPTIONAL PRESSURE MODULE 10,000 PSIG, WET FOR 718 Pressure Calibrator |  | Yes |  | 3,661,200 |  
| FL700PA3 |  | FLUKE-700PA3 |  | OPTIONAL PRESSURE MODULE, 0-5 PSIA FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PA4 |  | FLUKE-700PA4 |  | OPTIONAL PRESSURE MODULE, 0-15 PSIA FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PA5 |  | FLUKE-700PA5 |  | OPTIONAL PRESSURE MODULE, 0-30 PSIA FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PA6 |  | FLUKE-700PA6 |  | OPTIONAL PRESSURE MODULE, 0-100PSIA FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PCK |  | FLUKE-700PCK |  | OPTIONAL PRESSURE MODULE CALIBRATION KIT FOR 718 Pressure Calibrator |  | Yes |  | 1,358,640 |  
| FL700PD2 |  | 700PD2 |  | OPTIONAL PRESSURE MODULE +/- 1 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PD3 |  | FLUKE-700PD3 |  | OPTIONAL PRESSURE MODULE, +/- 5 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PD4 |  | FLUKE-700PD4 |  | OPTIONAL PRESSURE MODULE, +/- 15 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PD5 |  | FLUKE-700PD5 |  | OPTIONAL PRESSURE MODULE, -15/+30 PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PD6 |  | FLUKE-700PD6 |  | OPTIONAL PRESSURE MODULE, -15/+100PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700PD7 |  | 700PD7 |  | OPTIONAL PRESSURE MODULE, -15/+200PSIG FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| MR84066 |  | B34686 |  | OPTIONAL HAND PUMP/MODEL B34686 145 PSI (10 BARS) (961P) ** FOR 718 Pressure Calibrator |  | Yes |  | 702,000 |  
| FL700PV3 |  | FLUKE-700PV3 |  | OPTIONAL PRESSURE MODULE, -5 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  
| FL700SW |  | FLUKE-700SW |  | OPTIONAL DPC/TRACK FOR USE W/CALIBRATOR FOR 718 Pressure Calibrator |  | Yes |  | 3,877,200 |  
| FL700TC1 |  | FLUKE-700TC1 |  | OPTIONAL T/C MINI-PLUG KIT 10 COMMON TYPES FOR 718 Pressure Calibrator |  | Yes |  | 140,400 |  
| FL700TC2 |  | FLUKE-700TC2 |  | OPTIONAL T/C MINI-PLUG KIT 5 COMMON TYPES FOR 718 Pressure Calibrator |  | Yes |  | 118,800 |  
| FL700P00 |  | 700P00 |  | OPTIONAL PRESSURE MODULE, 0-1 IN, H20 DIFF. FOR 718 Pressure Calibrator |  | Yes |  | 3,013,200 |  
| FL700P27 |  | 700P27 |  | OPTIONAL Pressure Module, 0-30 PSIG, Wet FOR 718 Pressure Calibrator |  | Yes |  | 2,149,200 |  
| FL700PMP |  | FLUKE-700PMP |  | OPTIONAL PRESSURE PUMP FOR 718 Pressure Calibrator |  | Yes |  | 689,040 |  
| FL700PV4 |  | FLUKE-700PV4 |  | OPTIONAL PRESSURE MODULE, -15 PSID FOR 718 Pressure Calibrator |  | Yes |  | 2,581,200 |  |  |