(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

WKIS1030 HGVAC Intrinsically Safe Pressure Transmitter

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:WKIS1030HGVAC
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

The IS-10 industrial and IS-11 non-clogging flush diaphragm pressure transmitters are designed
The IS-10 industrial and IS-11 non-clogging flush diaphragm pressure transmitters are designed for industrial pressure measurement applications where intrinsically safe ratings are required. Each transmitter undergoes extensive testing and calibration to achieve an accuracy of 0.25% full scale. State-of-the-art surface mount technology ensures that the unit is protected against vibration, shock and humidity. Each unit is temperature compensated to assure accuracy and long-term stability under severe ambient temperature variations.

The compact design features all stainless steel wetted parts and is available with a variety of electrical and process connections to meet specific installation requirements.

 
Features
  • Approvals pending for Class I Division 1 and Class I Zone 0 locations when used with an approved barrier
  • 4-20 mA 2-wire output signal
  • Highly resistant to pressure spikes and vibration
 
SPECIFICATIONS

Accuracy

+ 0.25% Best Fit Straight Line
Wetted Parts 316SS and PH17 – 4 SS (>= 400 psi)
Case 316SS
Pressure Connection 1/2" NPT Male
Power Supply 10 – 30 V DC
Signal Output 4 – 20mA, 2-wire

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
WKIS1030HGVAC   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 30-0 Inches Hg Vacuum   Yes   1,026,000 
WKIS100050INWC   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0-50 Inches Water Column   Yes   853,200¡¡
WKIS100100INWC   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0-100 Inches Water Column   Yes   853,200¡¡
WKIS1000005PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 5 psi   Yes   853,200¡¡
WKIS1000010PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 10 psi   Yes   853,200¡¡
WKIS1000015PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 15 psi   Yes   853,200¡¡
WKIS1000025PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 25 psi   Yes   853,200¡¡
WKIS1000030PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 30 psi   Yes   853,200¡¡
WKIS1000050PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 50 psi   Yes   853,200¡¡
WKIS1000060PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 60 psi   Yes   853,200¡¡
WKIS1000100PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 100 psi   Yes   853,200¡¡
WKIS1000160PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 160 psi   Yes   853,200¡¡
WKIS1000200PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 200 psi   Yes   853,200¡¡
WKIS1000250PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 250 psi   Yes   853,200
WKIS1025000PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 25000 psi   Yes   2,581,200 
WKIS1040000PSI   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 40000 psi   Yes   2,581,200 
WKIS1000015PSIA   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 15 psi absolute   Yes   1,026,000¡¡
WKIS1000025PSIA   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 25 psi absolute   Yes   1,026,000
WKIS1000050PSIA   ¡¡ ¡¡ Intrinsically Safe Pressure Transmitter, 0 - 50 psi absolute   Yes   1,026,000¡¡