Features |
- A miniature, low-priced full-featured transmitter – just 1 lb. (450 grams)
- All welded 316 stainless steel construction and wetted parts (no aluminum)
- Ranges from 0-3 (0.2 bar) to 0-5000 psig (345 bar)
- +0.25% accuracy
- Zero and span adjustability
- Full 5:1 range turndown
- FM & CSA Explosion-proof and intrinsically safe
- 4-20 mA output at 12-40 VDC
- Watertight cable or conduit connection optional
- 1/2 in. NPT Female process connection or flush mount version
- Straight in-line construction for a slim profile
- 24 inch (61 cm) cable standard
|
| |
SERVICE |
Liquid, gas or vapor |
RANGE LIMITS |
0-3 to 0-6 psi (0-0.2 to 0-0.4 bar) |
3-15 psi (0.2-1.0 bar) |
0-6 to 0-15 psi (0-0.4 to 0-1.0 bar) |
0-15 to 0-30 psi (0-1.0 to 0-2.1 bar) |
0-20 to 0-100 psi (0-1.4 to 0-6.9 bar) |
0-60 to 0-300 psi (0-4.0 to 0-20.7 bar) |
0-200 to 0-1000 psi (0-14.0 to 0-69.0 bar) |
0-600 to 0-3000 psi (0-40.0 to 0-206.9 bar) |
0-1000 to 0-5000 psi (0-70.0 to 0-344.8 bar) |
OUTPUT |
4 to 20 mADC, limited to 30 mADC |
POWER SUPPLY |
12 to 40 VDC with reverse polarity protection |
LOOP RESISTANCE |
1400 ohms maximum at 40 volts |
TURNDOWN |
5:1 |
ZERO ADJUST |
+10% |
SPAN ADJUST |
+10% |
TEMPERATURE RANGE |
Ambient Operating |
FM Intrinsically Safe |
-40¡Æ to 140¡ÆF (-40¡Æ to 60¡ÆC) |
FM Explosion-proof |
-40¡Æ to 180¡ÆF (-40¡Æ to 82¡ÆC) |
CSA Intrinsically Safe T3C |
-40¡Æ to 140¡ÆF (-40¡Æ to 60¡ÆC) |
CSA Explosion-proof |
-40¡Æ to 180¡ÆF (-40¡Æ to 82¡ÆC) |
Process Interface |
-40¡Æ to 212¡ÆF (-40¡Æ to 100¡ÆC) |
Storage |
-40¡Æ to 212¡ÆF (-40¡Æ to 100¡ÆC) |
OVERRANGE |
300% upper range limit |
HUMIDITY LIMITS |
0 to 100% RH |
ACCURACY |
+0.25% of calibrated span including linearity, hysteresis and repeatability (BFSL) |
RESPONSE TIME |
Time constant of 20 milliseconds |
STABILITY |
+0.5% of upper range limit for six months |
TEMPERATURE EFFECT Compensated |
(includes zero and span) -20¡Æ to 180¡ÆF (-29¡Æ to 82¡ÆC) |
Between 30¡Æ and 130¡ÆF (-1¡Æ and 54¡ÆC): +1% of URL per 50¡ÆF (28¡ÆC) |
Between -20¡Æ and 180¡ÆF (-29¡Æ and 82¡ÆC): +1.6% of URL per 50¡ÆF (28¡ÆC) |
POWER SUPPLY EFFECT |
+0.005% full scale per volt |
SURGE PROTECTION |
Standard |
VIBRATION EFFECT |
+0.1% of upper range limit for 3 g to 200 Hz |
POSITION EFFECT |
Zero shifts up to 0.01 psi |
OVERRANGE EFFECTS |
+0.15% full scale per 200% of maximum range |
MATERIALS OF CONSTRUCTION |
Process Wetted Parts |
316 stainless steel |
Diaphragm (Models 851F) |
Hastelloy C |
Non-Wetted Parts |
316 stainless steel; Viton¢ç O-ring |
Fill Fluid |
DC 200 silicone (standard) |
Process Connection |
Reference model code |
Electrical Connection |
Reference model code |
Weight |
1 lb. (450 grams) |
Cable Length |
24 in. (61 cm), 22 AWG |
FACTORY MUTUAL |
Intrinsically safe for Class I, II, III Division I, Groups A, B, C, D, E, F, G for hazardous locations per AMETEK Dwg. BK750407. Maximum ambient temperature 60OC. |
Entity Requirement |
Imax = 225 mA, Vmax = 36V, Ci = 0.126 ¥ìf., Li = 0 mH |
Explosion-proof for Class I, II, III Division 1, Groups C, D, E, G, for hazardous locations. NEMA 4 Enclosure. Conduit seal must be within 18 inches of transmitter. |
CANADIAN STANDARDS ASSOCIATION |
Exia-Intrinsically safe for Class I, Division 1 & 2, Groups A, B, C, D; Class II, Groups E, F, G when connected per AMETEK Dwg. BK750483. Temperature code T3C. ( Product code C ) |
Explosion-proof for Class I, Division 1, Groups B, C, D; Class II, Groups E, F, G; Class III for hazardous locations. Enclosure 4.( Product code A ) |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
AM8510 |
|
851TG0015CLSA |
|
0-3 to 0-15 PSI, Pressure Transmitter |
|
Yes |
|
1,134,000 |
1/2" Female Conduit, Explosion-proof Rating |
AM8511 |
|
851TG0030CLSA |
|
0-6 to 0-30 PSI, Pressure Transmitter |
|
Yes |
|
1,134,000 |
1/2" Female Conduit, Explosion-proof Rating |
AM8512 |
|
851TG0100CLSA |
|
0-20 to 0-100 PSI, Pressure Transmitter |
|
Yes |
|
1,134,000 |
1/2" Female Conduit, Explosion-proof Rating |
AM8513 |
|
851TG0300CLSA |
|
0-60 to 0-300 PSI, Pressure Transmitter |
|
Yes |
|
1,134,000 |
1/2" Female Conduit, Explosion-proof Rating |
AM8514 |
|
851TG1000CLSA |
|
0-200 to 0-1000 PSI, Pressure Transmitter |
|
Yes |
|
1,198,800 |
1/2" Female Conduit, Explosion-proof Rating |
AM8515 |
|
851TG3000CLSA |
|
0-600 to 0-3000 PSI, Pressure Transmitter |
|
Yes |
|
1,198,800 |
1/2" Female Conduit, Explosion-proof Rating |
AM8516 |
|
851TG3000CLSA |
|
0-1000 to 0-5000 PSI, Pressure Transmitter |
|
Yes |
|
1,198,800 |
Flush Connection (only available up to 300 PSIG) add $35.00 1/2" Female Conduit, Explosion-proof Rating | | |