(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

FJ4113 Fixed transit time flowmeter converter

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:FJ4113
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

State-of-the-art, economical alternative to magnetic, vortex and differential pressure transmitters.
State-of-the-art, economical alternative to magnetic, vortex and differential pressure transmitters. Advanced microprocessing detection methods combine with a versatile design providing accurate and obstructionless flow measurement of any clean water application.

Features high reliability and accuracy, and long-term maintenance-free operation. Programming the Time Delta M is simple via the front panel keypad; no PC is required for setup.

The instrument features a high-resolution, 2-line, backlit display with signal quality indication. The non-intrusive, clamp-on sensors are quickly installed without interrupting process flows and with zero pressure loss.
 
SPECIFICATIONS

Performance - Ultrasonic Flow Converter/Meter FJ4113-4

 Fluid Conditions
 Measured Fluid Homogeneous liquids with minimal aeration (water, sea water, hydrocarbons or fluid with unknown sound velocity) capable of ultrasonic wave propagation
 Fluid Turbidity 10000 deg. (mg/l) or less
 State of Flow Well developed turbulent or laminar flow in full pipe
 Fluid Temperature -4¡Æ to 212¡ÆF (-20¡Æ to 100¡ÆC)
 Velocity Range 0.010 to 33 ft/sec (0 to 10 m/sec) bi-directional flow
Piping Conditions
 Pipe Material Carbon steel, stainless steel, cast iron, copper, PVC, aluminum, ductile iron, FRP, PEEK, PVDF, PTFE, PFA and others
 Pipe Size 1.0 to 9.0 in. (25 to 225mm)
 Lining Material Tar epoxy, mortar, rubber, others, none
Measurement Accuracy
 Accuracy Up to 0.5%, ¡¾2% rate typical on calibrated system
 Linearity ¡¾0.1% of scale
 Repeatability 0.5% or better
Functional Specifications - Ultrasonic Flow Converter/Meter FJ4113-4
 Power Supply 100 to 120 VAC ¡¾10%, 50/60 Hz
200 to 240 VAC ¡¾10%, 50/60 Hz
20 to 30 VDC
 Power Consumption Approx. 10 VA/5W (DC)
 LCD Display 2 line, 16 characters per line, backlight
 LED Display 2 color, green/red, signal quality
 Keypad 4-key, full menu-driven setup functionality
 Response Time 200 ms or less
 Analog Output Signal 4 to 20mA DC, multirange, fully programmable
 Digital Output Signal Digital output 2 mechanical relay, 1 point with socket. Normal open/close selectable, capacity 220 VAC/30 VDC, 1 Amp. Total pulse range 1 pulse per day to 1 pulse per second. Digital output 1 open collector transistor, 1 point. Normal on/off selectable, capacity 30 VDC, 0.1 Amp. Total pulse range 1 pulse per day to 100 pps.
 Digital Output Functions Forward/reverse totalizer pulse, flow switch high/low, forward/reverse total alarm and overflow, reverse flow detected
 Communications RS-232C/RS-485
 Interface Data: velocity, flow rate, +total, -total, status
Cable length: 50 ft. (15m) for RS-232C, 3280 ft (1000m) for RS-485
Number of connectable units: 31 (RS485), 1 (RS232C)
 Display Language English, French, German, Spanish
Physical Specifications - Ultrasonic Flow Converter/Meter FJ4113-4
 Ambient Temperature -4¡Æ to 140¡ÆF (-20¡Æ to 60¡ÆC)
 Ambient Humidity Less than 90% RH
 Enclosure ABS Plastic
 Environmental Rating NEMA-4X (IP65)
 Dimensions (HxWxD) 5.51 x 5.47 x 2.68 in. (140 x 139 x 68mm)
 Weight 1.76 lbs. (0.8 kg)
Detector Ultrasonic Flow Sensor FJ4115
 Mounting Method Detector mounting on outside of pipe via steel bands, nylon belts, or steel wire
 Straight Pipe Length Upstream side — 10D or more recommended, downstream side — 5D or more recommended
 Signal Cable RG-58, RG-58A/U, 3D2V
 Cable Length Maximum cable length 100 ft (30m)
 Connection Converter: internal screw
Detector: BNC (female)
 Ambient Temperature Range   -4¡Æ to 212¡ÆF (-20¡Æ to 100¡ÆC)
 Environmental Rating IP65
Material
 Housing Plastic PBT
 Mounting Bracket 304SS
Dimension & weight
 Dimensions (WxHxD) FLS22: 14.20 x 1.10 x 2.00 in.
 Weight FLS22: 0.9 lbs. (0.4 kg)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
FJ4113   FLRE2   Fixed transit time flowmeter converter, AC power input without sensor   Yes   3,186,000¡¡
FJ4114   FLRE4   Fixed transit time flowmeter converter, DC power input without sensor   Yes   3,186,000 
FJ4115   FLS22   1.0" to 9.0", -40°F to 212°F, FLR type 2 sensor   Yes   1,617,840 
FJ4116   TKUSTTFLRC1   RS232C Communications   Yes   451,440¡¡
FJ4117   TKUSTTFLRC2   RS485 Communications   Yes   386,640