The instrument¡¯s built-in display and setpoint control eliminate the need for separate power supply
Designed to control the flow of non-corrosive gases, the Model 810C Mass-Trak mass flow controller meets the same performance criteria as any industry-standard flow controller... at half the price.

The instrument¡¯s built-in display and setpoint control eliminate the need for separate power supply and readout electronics, necessary on most MFCs. A straight, large diameter sensor tube prevents clogging and contamination, and its stable, fast response valve provides precise one-step control of critical gas flows. You simply set it and forget it.

 
Features
  • Utilizes thermal sensing principle for mass flow measurements
  • Electromagnetic valve provides continuous control
  • Complete control system in one small package
  • Replaces obsolete rotameters
  • NIST traceable calibration ensures measurement accuracy
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
SA677110   810M   Mass Flow Meter   Yes   1,069,200
Standard configuration includes; 0-5 VDC and 4-20 mA linear output signals; 24 VDC input power; ¨ù " female NPT inlet/outlet fittings; Viton® ¡°O¡± rings; 15 pin D-connector and mating connector; calibrated for any flow range from 0 to 20 SCCM up to 50 SLPM equivalent nitrogen flow; 1.5% FS accuracy; maximum temperature 122 degrees F; maximum pressure 150 psig
SA677111   810C   Mass Flow Controller   Yes   1,890,000
Same as above, but includes integral flow control valve. Standard model requires 24 VDC regulated input power; switchable 0-5 VDC and 4-20 mA command signal 
SA677112   DR   OPTIONAL 3 1/2 digit display reading flow FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677113   1   OPTIONAL 1/8 inch compression fitting (up to 15 SLPM) FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677114   2   OPTIONAL ¨ù inch compression fitting FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677115   MP   OPTIONAL Medium Pressure (40-100 psig) FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677116   LF   OPTIONAL Low flow calibration (0 to 20 SCCM full scale flow range) FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677117   810-T8   OPTIONAL 110VAC power supply FOR Gas Mass Flow Controller   Yes   129,600