The 1000 series 1/4 Din conductivity and resistivity controllers have more features
The 1000 series 1/4 Din conductivity and resistivity controllers have more features than any other controllers in their price range! Their high +0.5% full-scale accuracy, 1 to 2000 second selectable time delay, and adjustable set point hysteresis bands mean you can trust these controllers for rapid on / off control of your critical processes.

Customize your controller to fit your exact application. Each unit is selectable for conductivity or resistivity control, isolated 0-20 or 4-20 mA recorder output; 70 or 220 VAC; normally activated or unactivated relays; normally open or closed relays; and manual or automatic temperature compensation. The compact 1¨ù4 DIN size fits into standard panel cutouts. The IP54 rated front panel keypad is weather resistant.

 
Features
  • Removable terminal blocks
  • Splash-resistant, IP64 rated membrane keypad
  • Mounting hardware for easy panel installation
  • Large dual display LCD for easy reading -features clear multiple annunciators, set points, and status and error messages
  • Two set point, two SPDT relay operation -choose from lo/lo, lo/hi, hi/lo or hi/hi control
  • Time delay adjustment on all relays -select from 1 to 2000 sec to minimize false alarms
  • Battery backup of memory maintains setup when power fails
  • Separate alarm relay -alerts you to set points exceeded for a specific length of time or a failed temperature sensor
  • Separately adjustable high and low set point hysteresis bands -prevent rapid contact switching if your measured value is fluctuating near the set point
  • Adjustable temperature coefficient -from 0.00 to 10.00% per ¡ÆC lets you input your solution¡¯s true temperature correction for higher accuracy
  • Choice of 0.01, 0.1, 1.0 or 10.0 cell constants -for accurate readings in any solution
  • 0-20/4-20 mA transmitter/recorder output — for remote monitoring and hard copy recording
  • Protected against electromagnetic interference — units that meet CE requirements are available
  • Push button keypad gives you fast access -to one-point calibration, switchable manual or automatic temperature compensation, and call up to view set points
  • Two level password protection -first level allows quick access to calibration: second level lets you change set-up parameters
  • LED indicators signal control activities -monitor controller status from a distance
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AK9462000   WD-35200-20   CONDUCTIVITY
CONTROLLER, 120VAC, 48 TO 62 HZ
  Yes   1,188,000 
AK9462002   WD-35200-40   RESISTIVITY CONTROLLER, 120VAC, 48 TO 62 HZ   Yes   1,188,000 
AK9461017   WD-35100-90   OPTIONAL POWER CORD; 3 FT W/BARE LEADS,70VAC FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   14,256

 

AK9462004   WD-35820-20   OPTIONAL CONDUCTIVITY CELL,EPOXY BODY, GRAPHITE ELECTRODES CELL ConSTANT=1.0, 3/4" NPT THREAD FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   303,480

 

AK9482005   WD-35820-21   OPTIONAL CONDUCTIVITY CELL, EPOXY BODY CELL ConSTANT= 0.1, 3/4" NPT THREAD FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   303,480

 

AK9462006   WD-35820-22   OPTIONAL CONDUCTIVITY CELL, EPOXY BODY CELL ConSTANT= 10, 3/4" NPT THREAD FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   303,480

 

AK9462007   WD-35820-25   OPTIONAL CONDUCTIVITY CELL, GLASS BODY, PLATINUM ELECTRODES CELL ConSTANT= 1, 3/4" NPT THREAD FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   354,888

 

AK9462008   WD-35820-26   OPTIONAL CONDUCTIVITY CELL, GLASS BODY, PLATINUM ELECTRODES CELL ConTANT= 0.1, 3/4" NPT THREAD FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   403,056

 

AK9462009   WD-35820-40   OPTIONAL CONDUCTIVITY CELL CELL ConSTANT=0.01, 3/4" NPT THREAD FOR 1/4 DIN Conductivity and Resistivity Controllers   Yes   415,152