These include simple automated calibration,3 year(9,000 hours)power(camera battery available in local stores)
GasAlert¢â provides extraordinary cost of ownership advantages. These include simple automated calibration, 3 year (9,000 hours) power (camera battery available in local stores) and simple one-button operation. All of these features lower your training and maintenance costs.
Operated by an advanced microcontroller and a plug-in electrochemical sensor, the GasAlert¢â is equipped with high output audible/visual alarms. The bright large LCD shows real-time gas concentrations and the instruments status at all times.
The full function self-test verifies sensor, circuit and battery integrity and activates the audible/visual alarms each time you turn the instrument on. The detector clearly advises the hazard level present - Low, High, or TWA. TWA (Time Weighted Average) and Peak exposures are displayed on demand.
The compact, rugged GasAlert¢â is designed with the most advanced RFI protection available today. Delivered ready for use, simply clip the instrument to your lapel, pocket, belt or hard hat for unequalled protection.
Features
Continuous LCD shows real-time gas concentration with backlight–low light (auto); in alarm (auto) and on demand
Small size (1.1 x 2.0 x 3.75 in. / 28 x 50 x 95 mm) and lightweight (2.9 oz. / 83 g)
Provides 90 dB tone and bright LED indication on alarm
3-year battery life (9,000 hours)
Available with internal vibrating alarm
Equipped with plug-in replaceable sensors
Simple auto-zero and calibration procedure
Peak value displayed on command (in ppm or %)
LOW, HIGH and TWA alarms with adjustable setpoints
TWA (Time Weighted Average) values are recorded and displayed to evaluate the cumulative exposure danger and to aid regulatory compliance
Classified intrinsically safe by UL to U.S. and Canadian standards, Cenelec certified, certified in Australia
Full function self-test of: sensor, battery and circuitry integrity; and audible/visual alarms
Pocket/belt clip, test cap and hose, battery and instructions in local languages included
SPECIFICATIONS
GasAlert for:
Measuring Range
Alarm (Factory defaults are shown. Alarm levels are field-adustable.)
Operating Temperature
Low Alarm
TWA Alarm
High Alarm
Hydrogen Sulfide (H2S)
0-100 ppm
10 ppm
10 ppm
15 ppm
-40 to +50 ¡ÆC -40 to +122 ¡ÆF
Carbon Monoxide (CO)
0-999 ppm
35 ppm
35 ppm
200 ppm
-20 to +50 ¡ÆC -4 to +122 ¡ÆF
Sulfur Dioxide (SO2)
0-1009 ppm
2 ppm
2 ppm
5 ppm
¡¡
Chlorine (CI2)
0-50.0 ppm
0.5 ppm
0.5 ppm
1.0 ppm
Auto zero
Yes
Calibration
Automatic
Backlight
Low light (auto); alarm condition (auto); on demand
Full function self-test
Verifies integrity of sensor, circuitry and battery; audible/visual alarms