(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

BW21011 100 day Hydrogen Sulfide (H2S)

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:BW21011
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

100 days of protection with no maintenance costs—ideal for employees
Features
  • 100 days of protection with no maintenance costs—ideal for employees and contractors for short-term work projects
  • Maintenance free – no sensor or battery replacement/charging, no calibration, no downtime
  • Small size (1.0 x 1.45 x 2.3 inches / 26 x 37 x 58 mm) and lightweight (1 oz. / 30 g)
  • Full function self-test of: audible/visual alarms plus integrity of sensor, battery and circuitry
  • Continuously ON – one button activation and test
  • Provides ≈95 dB tone
  • Confidence LCD display advises instrument is on and functioning
  • Continuous, alphanumeric LCD shows detector life remaining, alarm setpoints and advises self-test status
 
SPECIFICATIONS

General

Impact-resistant ABS enclosure
EMI/RFI Complies with EMC Directive 89/336/EEC
Battery Lithium, non-replaceable
Sensor Electrochemical cell (temperature compensated)
Warranty 100 days from activation, plus 1 year shelf-life
Model GasAlert100 H2S GasAlert100 CO
Operational life 100 days 100 days
Sensor range 0-100 ppm 0-300 ppm
Low alarm level 10 ppm 35 ppm
High alarm level 15 ppm 200 ppm
Operating temperature -22 to +113 ¡ÆF +5 to +113 ¡ÆF
  -30 to +45 ¡ÆC -15 to +45 ¡ÆC
Calibration Not required Not required
Indicators and Alarms
Visual gas alarm Flashing, wide-angled alarm lens with dual red LEDs plus ALARM LCD
Readout audible gas alarm Pulsing siren ≈95 dB at 1 ft./0.3 m
Other Low battery, failure alarm, self-test pass, and end of life (audible/visual)
Life remaining Continuously displayed in days and then hours
Two alarm levels LOW alarm / HIGH alarm
Alarm setpoints High and low (displayed on demand in ppm)
Self-test status Advises to "TEST" and that self-test was passed

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
BW21011   GA100-H   100 day Hydrogen Sulfide (H2S)   Yes   321,840
BW21012   GA100-M   100 day Carbon Monoxide (CO) Detector   Yes   321,840