ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù > Å©·¥ÇÁ¸ÞÅÍ Clamp Meter Àü·ÂÃøÁ¤¿ë ¸ÖƼ¸ÞÅÍ Àü·ÂÃøÁ¤¿ë ·Î°Å Àü·ÂºÐ¼®±â ÀúÇ×ÃøÁ¤±â Ohm Meters Á¢ÁöÀúÇ×ÃøÁ¤±â Ground Resistance ÀϹÝÃøÁ¤±â ±Ý¼ÓŽÁö±â Metal, Cable Locator ÇöÀç ºÐ·ù
YK1402 Clamp-On Power Meter
These Clamp-On Power Meters are lightweight and easy to use.
These Clamp-On Power Meters are lightweight and easy to use. They offer the latest technology in power quality monitoring and analysis. A large LCD screen displays menu graphics and various power parameters such as voltage (VRMS), current (ARMS), active power (W), reactive power (VAR), and frequency (Hz). The YK1402 and YK1404 have an internal 1 MB memory that can log and store measurements for up to 1,000 hours (in 1 minute intervals. The YK1405 and YK1406 are compatible with 128MB flash memory cards which means that 1 year of data can be stored at 30 minute intervals. Data can be viewed in four (4) different modes: instant mode, demand mode, electric energy mode, and harmonic mode. Measured parameters include Power Factor and Phase angle in addition to those listed above. For harmonic analysis, the 1st through 13th order harmonics can be displayed in an easy-to-understand bar graph format or as numeric values. The carrying case lets you carry the current and voltage probes without disconnecting them from the unit. And there is plenty of room left over for accessories.
Features for YK1402 & YK1404
Graphical LCD Screen
Store 1000 hours of data via 1 MB internal memory
Connectors accept 4 current clamps
Measure loads on two (2) power systems
Measure and View Harmonics
Features for YK1405 & YK1406
Graphical Backlit LCD Screen
Measure from 5 – 3000 Amps AC (using clamps)
Measure up to 1 year of data in 30-minute intervals
Save data to PC via RS-232 or RS-485
Compact Design (4.6" x 6.3" x 2")
YK1405: (1P2W, 1P3W & 3P3W); YK1406: (1P2W, 1P3W, 3P3W & 3P4W)
SPECIFICATIONS – YK1402 and YK1404
Temperature and Humidity
Operating
5 to 40¡ÆC, 35 to 80% RH
Power
Adapter, 100-240 VAC, 50/60 Hz. (included)
Battery
NiMH Battery Pack — 7 hours run time AA (6) Alkaline — 3 hours run time (included)
Terminals
Voltage Input
4 Banana Type
Current Input
4 Banana Type
External Control
2 H/L Screwless Terminals
Event Input
2 H/L Screwless Terminals
D/A Output
2 H/L Screwless Terminals
Dimensions
206 (W) x 65 (H) x 184 (D) mm
Weight
1.2 kg approximately
SPECIFICATIONS – YK1405 and YK1406
Voltage
0 – 150/300/450 V AC (+ 0.3% rdg + 0.2% rng)
Current/Active Power
0 – 700 amps + 0.8 rdg + 0.4% mg)
Frequency
45 – 65 Hz + (0.1% rdg + 1 digit)
Power
+ (0.5% rdg + 0.4% mg + 1V to 700 amps)
Sampling Rates
1/2/5/10/15/30 seconds; 1/2/5/10/15/30 minutes; 1 hour
CAT NO.
MODEL
DEscRIPTION
AVAIL
PRICE
YK1402
CW140D /C2/PM1
Clamp-On Power Meter with (4) 200A, current clamps, case and NIMH battery pack
Yes
6,486,480
YK1404
CW140D /C4/PM1
Clamp-On Power Meter with (4) 500A, current clamps, case and NIMH battery pack
Yes
6,819,120
YK1405
1201
Clamp-On Power Meter 1P2W, 1P3W & 3P3W (must select clamps from accessories)
Yes
2,203,200
YK1406
1202
Clamp-On Power Meter 1P2W, 1P3W & 3P3W (must select clamps from accessories)
Yes
2,484,000
YK96030
960-30
OPTIONAL Clamp-On Probe 200 A AC/600V FOR Yokogawa Clamp-On Power Meter
Yes
496,800
YK96031
960-31
OPTIONAL Clamp-On Probe 500A AC/600V FOR Yokogawa Clamp-On Power Meter
Yes
550,800
YK96032
960-32
OPTIONAL Clamp-On Probe 700A AC/600V FOR Yokogawa Clamp-On Power Meter
Yes
624,240
YK96033
960-33
OPTIONAL Clamp-On Probe 50A AC/300V FOR Yokogawa Clamp-On Power Meter
Yes
453,600
YK96034
960-34
OPTIONAL Clamp-On Probe 1000A AC/600V FOR Yokogawa Clamp-On Power Meter
Yes
896,400
YK96035
960-35
OPTIONAL Clamp-On Probe 300A/3000A AC/300V FOR Yokogawa Clamp-On Power Meter
Yes
1,121,040
YK93020
930-20
OPTIONAL Carrying Case (CW140 Series) FOR Yokogawa Clamp-On Power Meter
Yes
518,400
YK366969
366969
OPTIONAL AC Adapter with Power Cord (CW140) FOR Yokogawa Clamp-On Power Meter
Yes
216,000
YK94004
940-04
OPTIONAL NiMH Battery Pack FOR Yokogawa Clamp-On Power Meter
Yes
388,800
YK94006
940-06
OPTIONAL AC Adapter for Printer (Europe) FOR Yokogawa Clamp-On Power Meter
Yes
216,000
YK97007
970-07
OPTIONAL AC Adapter for Printer (US) FOR Yokogawa Clamp-On Power Meter
Yes
216,000
YK97080
970-80
OPTIONAL Thermal Printer Paper FOR Yokogawa Clamp-On Power Meter
Yes
129,600
YK91007
910-10
OPTIONAL Voltage Probe FOR Yokogawa Clamp-On Power Meter
Yes
64,800
YK9017
B9017VD
OPTIONAL RS232 Cable (to PC) FOR Yokogawa Clamp-On Power Meter
Yes
108,000
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.