BD210800 Insulation and Continuity Tester

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:BD210800
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Includes zip-up carry case, 1set test leads including prods and clips and operating instruction book.
Includes zip-up carry case, 1set test leads including prods and clips and operating instruction book.
 
Features
  • Suitable for testing to the IEE Wiring Regulations
  • Complies with the requirements of BS 7671, HD 384 and IEC 364
  • Combined insulation and continuity testing
  • Insulation testing at 500 V d.c. to the VDE 0413 Part 1
  • 3 Year Warranty
 
SPECIFICATIONS

Model

BD210800

BD210801

Insulation Test Voltage Ranges
500 V d.c.

500 V d.c.

Insulation Resistance Range
0 to 200 MW

0 to 200 MW

Resistance Range

0 to 1 MW

Continuity Ranges
0 to 200 W

0 to 200 W

 
0 to 2 W

0 to 2 W

Voltage Range
0 to 600 V a.c.

Terminal Voltage Insulation Resistance Range
<600 V (>500V at 0.5 M¥Ø)

<600 V >500V at 0.5 M¥Ø)

Terminal Voltage Resistance Range

53 V

Terminal Voltage Continuity Ranges
0.76 V

0.76 V

 
4.7 V

4.7 V

Terminal Current Insulation Resistance Range
1.6 mA

1.6 mA

Terminal Current Resistance Range

325 ¥ìA

Terminal Current Continuity Ranges
12.3 mA

12.3 mA

 
210 mA

210 mA

Accuracy (at 20¡ÆC) [2.5% of scale length on all ranges (i.e., ¡¾1.9 mm (0.075 in.) on insulation resistance range]
Movement
250 ¥ìA full scale deflection

250 ¥ìA full scale deflection

Voltmeter Input Impedance
330 k¥Ø

Power Supply Single 9 volt battery, IEC 6 LR61 type
Current Consumption 70 mA max. on insulation range, 40 mA max. on resistance range, 220 mA max. on 2¥Ø range
Battery Life More than 1800 5 second operations on 2¥Ø range
Safety The instruments will, in general, meet the requirements of the IEC 1010-1 (1990) safety specification.
Safety Class II, Flash test to 4 kV peak impulse. Phase-to-Phase voltages not exceeding 500V a.c.
Weight/Dimensions 485 g (1 lb approx)/175 H x 95 W x 57 D mm (6.9 H x 3.75 W x 2.25 D in. approx)

CAT NO. MODEL DEscRIPTION AVAIL PRICE
BD210800   BM100/4   Insulation and Continuity Tester   Yes   1,069,200
BD210801   BM101/4   Insulation and Continuity Tester   Yes   1,004,400
BD1210171   6420-030   OPTIONAL Synthetic test and carry case FOR Analog Insulation and Continuity Testers   Yes   259,200