(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

BB2109 Insulation Resistance Tester

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:BB2109
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Accurately measures insulation resistance to 3 T¥Ø with guard
Features
  • Accurately measures insulation resistance to 3 T¥Ø with guard
  • Unique illuminated ¡°Quick-Probe¡± for fast, hands-free testing
  • Special true sinusoidal AC test voltage to accurately measure both capacitance and inductance
  • Combined digital and analog display for both test voltage and resistance
  • Special medium voltage test safely estimates leakage current up to 600V equipment
  • Standard low resistance testing and automatic polarity switching and continuity beeper
  • Rugged, splashproof and complete in fitted case with leads
  • Optional RS-232 for printer or computer (Select Model BB2111)
  • BB270 features insulation testing to 3 T¥Ø with guard, true sinusoidal AC resistance testing, equivalent leakage current test
  • Preset as well as variable test voltage from 50V to 1000VDC
 
SPECIFICATIONS

Insulation Resistance Measurement

 Signal: 50 to 1000V variable plus 100, 250, 500 and 1000V fixed ranges
 Ranges: 7¥Ø to 3 T¥Ø on ISO-X with guard (70¥Ø to 30 G¥Ø on ISO)
 Resolution: 1¥Ø to 1G¥Ø on ISO-X (10¥Ø to 10M¥Ø on ISO)
 Accuracy: ¡¾3% of measured value plus 2 digits up to 30G¥Ø varies from 30G¥Ø to 3G¥Ø on ISO-X with Guard, call for details
 Standard Resistance Measurement
 Signal: <20 VDC
 Ranges: 0.12¥Ø to 3k¥Ø auto-ranging (0.03¥Ø to 30k¥Ø on ISO)
 Resolution: 0.01¥Ø to 1¥Ø (0.1¥Ø to 10¥Ø on ISO)
 Accuracy: ¡¾5% of measured value plus 3 digits
 Standard Voltage Measurement
 Ranges: 1 to 600V DC plus 45 to 400Hz AC: Resolution 1V
 Accuracy: ¡¾1% of measured value plus 1 digit
 Sinusoidal Insulation resistance
 Signal: 40 V 50 Hz sine wave (ISO-X only)
 Ranges: 31¥Ø to 30M¥Ø
 Resolution: 10¥Ø to 10k¥Ø
 Accuracy: ¡¾3% of measured value plus 3 digits
 Equivalent Leakage Current Test
 Signal: 40 V 50 Hz sine wave
 Range: 0.12 to 30mA
 Resolution: 10 micro Amps
 Accuracy: ¡¾5% of measured value plus 3 digits

CAT NO. MODEL DEscRIPTION AVAIL PRICE
BB2109   A186506111   INSULATION RESISTANCE TESTER   Yes   2,095,200
50 to 1000V, analog/digital display, battery powered, measures up to 30 G ohms complete with batteries, leads and case 
BB270   A186506211   INSULATION RESISTANCE TESTER W/GUARD   Yes   2,775,600
For measurement ranges up to 3 T ohms plus sinusoidal tests for leakage current and surface resistance testing
BB2111   A186506212   INSULATION RESISTANCE TESTER W/RS232   Yes   4,136,400
BB2112   A691440210   QUICK PROBE-HANDY ISO/UNILAP ISO SERIES   Yes   356,400