| Model CFL535E is an advanced instrument capable of identifying a wide range of cable faults using Time Domain Reflectometry. Narrow pulses of electrical energy are transmitted along the cable. The pulse travels through the cable at a velocity determined by the cable insulation. Changes in characteristic impedance of the cable will cause the pulse to be reflected which then is displayed on the instrument. |
| |
|
Features |
- Automatic event finder key
- Graphical help menu
- No blocking filter required for live line testing up to 480 VAC
- Dual input and output ports
- RS-232 interface to a PC or printer (included software)
- 15 internal memory locations
- 5 user selectable pluse widths per range
- Trace averaging
- Real time and Xtalk memory modes
- 3 Year Warranty
- IP54 rated
|
| | | SPECIFICATIONS
|
Ranges |
150 ft, 300 ft, 600 ft, 1200 ft, 3000 t, 6000 ft, 12,000 ft, 24,000 ft, and 48,000 ft (50 m, 100 m, 200 m, 400 m, 1 km, 2 km, 4 km, 8 km, and 16 km) |
| Resolution |
4 in. up to 600 t (0.1 m up to 200 m) |
| 8 in. up to 1200 ft (0.2 m up to 400 m) |
| 0.1% of range over 1200 ft (400 m) |
| Accuracy |
0.1% of all ranges |
| Gain |
0 to 90 dB in steps of 6 dB |
| Velocity Factor |
Variable from 0.300 to 0.999 in steps of 0.001 |
| Output pulse |
14 V peak to peak into open circuit |
| 7 V peak to peak into 120 ¥Ø |
| Pulse width user selectable for each range |
| 150 ft range |
20 ns, 40 ns, 60 ns, 80 ns, 1000 ns |
| 300 ft range |
20 ns, 50 ns, 80 ns, 100 ns, 140 ns |
| 600 ft range |
20 ns, 60 ns, 100 ns, 140 ns, 200 ns |
| 1200 ft range |
40 ns, 80 ns, 160 ns, 200 ns, 400 ns |
| 3000 ft range |
80 ns, 160 ns, 260 ns, 500 ns, 1 ¥ìs |
| 6000 ft range |
160 ns, 260 ns, 500 ns, 1 ¥ìs, 2 ¥ìs |
| 12,000 ft range |
250 ns, 500 ns, 1 ¥ìs, 2 ¥ìs, 4 ¥ìs |
| 24,000 ft range |
500 ns, 1 ¥ìs, 2 ¥ìs, 4 ¥ìs, 8 ¥ìs |
| 48,000 ft range |
1 ¥ìs, 2 ¥ìs, 4 ¥ìs, 8 ¥ìs, 16 ¥ìs |
| Modes |
Real Time |
| XTalk |
| Output Impedance |
Balanced to 120 ¥Ø |
| Balance Adjustment |
0 to 120 ¥Ø |
| Power |
Six LR6 (AA) type batteries, Manganese-alkali or nickel-cadmium cells |
| Nominal voltage: 12 V for alkaline or 9.32 V for NiCad |
| Safety |
Complies with IEC61010 |
| EMC |
BS/EN50081-1-1992 |
| BS/EN50082-1-1992 |
| Dimensions/Weight |
9.8 H x 7.9 W x 4.3 D in. (250 H x 200 W x 70 D mm) 3.3 lb (1.5 kg) |
| Operational Temperature |
5¡ÆF to 122¡ÆF (-15¡ÆC to +50¡ÆC) |
| Operational Humidity |
95% at 104¡ÆF (40¡ÆC) |
| CAT NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| BD655535 |
|
655535F |
|
General Purpose Time Domain Reflectometer |
|
Yes |
|
6,037,200 |
| Includes carry pouch, bed of nails test lead set, carry strap for pouch and instruction manual. |
| BD535112 |
|
CFL535FM |
|
General Purpose Time Domain Reflectometer, monochrome display with rechargeable battery and accessories |
|
Yes |
|
6,037,200
|
| BD535113 |
|
CFL535FR |
|
General Purpose Time Domain Reflectometer, color display with rechargeable battery and accessories |
|
Yes |
|
6,469,200
| | |