The new 1/16th DIN controller provides a new level of user convenience. The scrolling text messages deliver plain language messages to let operators and engineers alike know exactly what is happening to the process.
The Load Current Transformer Input, CT input, provides the ideal method to monitor load current and provide immediate indication of load conditions. Partial load failure, heater open circuit or contactor short circuit can each be indicated by clear scrolling operator messages and relay output.
The new 3-color LCD display provides clear indication of process variables. The upper display shows the process measured value while the lower display can be set to display a range of parameters including, setpoint, time remaining and current.
The communications option provides full system integration through the industry standard modbus protocol. |
|
Features |
- Quick Start Wizard makes configuration simpler that eve
- Up to 10 text messages of 30 characters in length
- Configurable operator interface with security access
- CT input for partial load failure, heater failure or contactor short circuit
- Universal inputs provide for thermocouple, 2 or 3-wire RTD, mV and mA inputs
- Digital communications
- Custom linearization using iTools
- Three outputs for any combination of heating, cooling or alarm
- Ideal for plastic extruders, small ovens, chillers, trace heating, packaging machines
|
| | SPECIFICATIONS
Dimensions |
48W x 48H x 90D mm |
Control modes |
PID or On/Off, heat/cool, heat only, cool only |
Supply voltages |
85-264Vac or 24Vac/dc (6 watts max.) |
Operating ambient |
0 to 50 deg C, 5% to 85% RH, non condensing |
Inputs |
Thermocouples, Pt100 3 wire, 0-50mV, 4-20mA, 0-20mA, Custom linearisation |
Current transformer input |
50mA ac into 10R |
Communications |
Modbus, RS232, RS485 2 wire |
Output ratings |
Relay: 2A, 264Vac resistive, Logic out: 12Vdc |
Digital in |
contact closure or logic |
Panel sealing |
IP65, NEMA 4X, plug-in from front panel |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
CH32161 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, J thermocouple, degrees F |
|
Yes |
|
572,400 |
CH32162 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, CT input, J thermocouple, degrees F |
|
Yes |
|
615,600 |
CH32163 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, CT input, J thermocouple, degrees F, Modbus RS485 comms. |
|
Yes |
|
710,640 |
CH32164 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, relay high alarm, J thermocouple, degrees F |
|
Yes |
|
645,600 |
CH32165 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, CT input, relay high alarm, J thermocouple, degrees F |
|
Yes |
|
918,000
|
CH32166 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, CT input, relay high alarm, J thermocouple, degrees F, Modbus RS485 comms. |
|
Yes |
|
810,000
|
CH32167 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, relay cool output, relay high alarm, J thermocouple, degrees F |
|
Yes |
|
594,000
|
CH32168 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, relay cool output, CT input, relay high alarm, J thermocouple, degrees F |
|
Yes |
|
710,640
|
CH32169 |
|
¡¡ |
¡¡ |
AC supply, logic heat output, relay cool output, CT input, relay high alarm, J thermocouple, degrees F, Modbus RS485 comms. |
|
Yes |
|
831,600
|
CH32170 |
|
¡¡ |
¡¡ |
iTools configuration software, instrument communications required |
|
Yes |
|
710,640 | | |