(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

CR41105 True RMS AC current transducer

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:CR41105
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Available Ranges: 0.5, 5, 10, 15, 20, 25, 30, 40, 50, 75, 100, 150 Amps AC
Available Ranges: 0.5, 5, 10, 15, 20, 25, 30, 40, 50, 75, 100, 150 Amps AC

Note: Two and Three Phase units available in 0.5 thru 15 Amps only
Use High Accuracy Current Transformers to extend Ranges

Additional Ranges available for True RMS Transducers (50, 250 Volts AC)

Applications
  • Motor, Pump, and Heater Monitoring
  • SCR Heater Control
  • Variable Frequency Drives
  • Generator Sets
  • Voltage Monitor
  • Panel or DIN Rail Mounts
SPECIFICATIONS

Basic Accuracy

¡¾0.5% Full Scale
Calibration True RMS
Thermal Drift 500 PPM/¡ÆC
Operating Temp. 0 to 50¡ÆC
MTBF >100,000 Hrs
Respnse Time 250 mS
Insulation Voltage 2500 VDC
Supply Voltage 24 VDC
Frequency Range 20-5 KHz
Output Loading
0-5 >2000 Ohm
4-20 mA 0-300 Ohm
Case Dimensions
Current and Three Phase Voltage
2.99" H x 3.27" W x 1.42" D

Single Phase Voltage
2.20" H x 3.27" W x 1.42" D

Current Sensor Hole Size
Single Phase-0.79" diameter
Two Phase- 0.26" diameter
Three Phase- 0.26" diameter

CAT NO. MODEL DEscRIPTION AVAIL PRICE
CR41105 CR470-5 True RMS AC current transducer, single phase 0-5VDC Out, 0-5A Usually ships in 7 to 10 days 378,000
CR411020 CR470-20 True RMS AC current transducer, single phase 0-5VDC Out, 0-20A Usually ships in 7 to 10 days 378,000
CR411050 CR470-50 True RMS AC current transducer, single phase 0-5VDC Out, 0-50A Usually ships in 7 to 10 days 378,000
CR41205 CR4120-5 True RMS AC current transducer, single phase 4-20mADC Out, 0-5A Usually ships in 7 to 10 days 421,200
CR412020 CR4120-20 True RMS AC current transducer, single phase 4-20mADC Out, 0-20A Yes 421,200
CR412050 CR4120-50 True RMS AC current transducer, single phase 4-20mADC Out, 0-50A Usually ships in 7 to 10 days 421,200
CR41505 CR4150-5 True RMS AC current transducer, 2-phase 0-5VDC Out, 0-5A Usually ships in 7 to 10 days 645,840
CR415015 CR4150-15 True RMS AC current transducer, 2-phase 0-5VDC Out, 0-15A Usually ships in 7 to 10 days 645,840
CR41605 CR4160-5 True RMS AC current transducer, 2-phase 4-20mADC Out, 0-5A Usually ships in 7 to 10 days 753,840
CR416015 CR4160-15 True RMS AC current transducer, 2-phase 4-20mADC Out, 0-15A Usually ships in 7 to 10 days 753,840
CR41705 CR4170-5 True RMS AC current transducer, 3-phase 0-5VDC Out, 0-5A Usually ships in 7 to 10 days 948,240
CR417015 CR4170-15 True RMS AC current transducer, 3-phase 0-15VAC, 0-15A Usually ships in 7 to 10 days 948,240
CR41805 CR4180-5 True RMS AC current transducer, 3-phase 4-20mADC Out, 0-5A Usually ships in 7 to 10 days 1,047,600
CR418015 CR4180-15 True RMS AC current transducer, 3-phase 4-20mADC Out, 0-15A Usually ships in 7 to 10 days 1,047,600
CR4510150 CR4510-50 True RMS voltage transducer, single phase 0-5VDC Out, 0-150VAC Usually ships in 7 to 10 days 378,000
CR4510500 CR4510-500 True RMS voltage transducer, single phase 0-5VDC Out, 0-500VAC Usually ships in 7 to 10 days 378,000
CR4520150 CR4520-150 True RMS voltage transducer, single phase 4-20mADC Out, 0-150VAC Usually ships in 7 to 10 days 421,200
CR4520500 CR4520-500 True RMS voltage transducer, single phase 4-20mADC Out, 0-500VAC Usually ships in 7 to 10 days 421,200
CR4550150 CR4550-150 True RMS voltage transducer, 3 wire, 3-phase, 0-5VDC Out, 0-150VAC Usually ships in 7 to 10 days 645,840

CR4550500 CR4550-500 True RMS voltage transducer, 3 wire, 3-phase, 0-5VDC Out, 0-500VAC Usually ships in 7 to 10 days 645,840

CR4560150 CR4550-150 True RMS voltage transducer, 3 wire, 3-phase, 4-20mADC Out, 0-150VAC Usually ships in 7 to 10 days 753,840

CR4560500 CR4550-500 True RMS voltage transducer, 3 wire, 3-phase, 4-20mADC Out, 0-500VAC Usually ships in 7 to 10 days 753,840

CR4570150 CR4570-150 True RMS voltage transducer, 4 wire, 3-phase, 0-5VDC Out, 0-150VAC Usually ships in 7 to 10 days 948,240

CR4570500 CR4570-500 True RMS voltage transducer, 4 wire, 3-phase, 0-5VDC Out, 0-500VAC Usually ships in 7 to 10 days 948,240

CR4580150 CR4580-150 True RMS voltage transducer, 4 wire, 3-phase, 4-20mADC Out, 0-150VAC Usually ships in 7 to 10 days 1,047,600

CR4580500 CR4580-500 True RMS voltage transducer, 4 wire, 3-phase, 4-20mADC Out, 0-500VAC Usually ships in 7 to 10 days 1,047,600