Action Instruments has pioneered wide-ranging, field configurable instrument design for over 12 years. The Ultra SlimPak Series utilizes ASIC and microprocessor based technologies to provide 1800VDC isolation and wide ranging adjustments for easy, accurate, discrete signal conditioning. The power supply of the Ultra SlimPak will accept any DC source between 9 and 30VDC, (except G448, 18-30VDC) typically a 12 or 24VDC supply is used.
The value of a field configurable instrument is that it allows the user to easily set the instrument for their specific or even custom I/O range. This flexibility can reduce spare parts inventory or increase the efficiency of the process by maximizing resolution in critical process measurements.
Limit Alarms Limit Alarms are setpoint controllers that regulate industrial processes, discrete, batch or continuous. Alarms are indicators of problems, be they production line faults, process upsets, equipment failures or control system abnormalities.
Signal Conditioners Signal Conditioners amplify and condition weak signals generated by process sensors. They send signals longer distances without being degraded by electrical noise. They are used to drive devices such as indicators, alarms, controllers, computer interfaces and other process instrumentation.
ASIC Reliability - Lifetime Warranty Action Instrument¡¯s exclusive analog ASIC design increases reliability by reducing components and interconnections up to 70%. Every Ultra SlimPak is backed by a Lifetime Warranty. |
|
Features |
- Easy Field-Configurable Input Ranges
- Covers all Major Input Types: AC/DC Voltage or Current, RTD, Thermocouple, Strain Gauge, Frequency and Potentiometer
- Ultra Slim Housing Mounts on DIN Rail for High Density Installations
- Limit Alarm and Signal Conditioner Models
- Flexible Power Supply Accepts 9 to 30VDC
- ASIC Technology for High Reliability
- Lifetime Warranty
|
| |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
ACT1002 |
|
G108-0001 |
|
DC Input Field-configurable Dual Limit-alarm, 9 - 30V DC |
|
Yes |
|
604,800 |
Input Type |
|
DC Volt, DC Current |
Field Configurable Input, Min./Max. Span |
|
10mV/200V*, 1mA/100mA* - * Bipolar switch for +/- 100% span |
Housing |
|
EG12 |
Field Configurable Output Type |
|
Alarm (Dual SPDT Relay), 1 Relay per Set Point |
ACT1004 |
|
G118-0002 |
|
RTD Input, Wide Ranging Limit Alarm, Dual Trip, SPDT Relays, 9 - 30V DC |
|
Yes |
|
604,800 |
ACT1006 |
|
G128-0001 |
|
TC Input, Wide Ranging, Limit Alarm, Dual Trip, SPDT Relays, 9 - 30V DC |
|
Yes |
|
604,800 |
ACT1010 |
|
G168-0001 |
|
AC Input, Wide Ranging, Limit Alarm, Dual Trip, SPDT Relays, 9 - 30V DC |
|
Yes |
|
604,800 |
ACT1001 |
|
G408-0001 |
|
DC Input Field Configurable Isolator, 9 - 30V DC |
|
Yes |
|
561,600 |
Input Type |
|
DC Volt, DC Current |
Field Configurable Input Type Min/Max Span |
|
10mV/100V, 1mA/100mA |
Housing |
|
EG8 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V) DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT1012 |
|
G408-1001 |
|
¡¡ |
¡¡ |
Yes |
|
561,600 |
DC Input, Wide Ranging, Isolated Conditioner, Field Configurable DC Bipolar Output, 9 - 30V |
ACT1003 |
|
G418-0001 |
|
RTD Input, Field Configurable Isolator, 9 - 30V DC |
|
Yes |
|
648,000 |
Input Type |
|
RTD |
Field Configurable Input, Min./Max. Span |
|
Platinum RTD, Copper RTD -200 Deg. C / -600 Deg. C |
Housing |
|
EG12 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT1005 |
|
G428-0001 |
|
T/C Input Field configurable Isolator, 9 - 30V DC |
|
Yes |
|
648,000 |
Input Type |
|
Thermocouple |
Field Configurable Input, Min./Max. Span |
|
B: 250 DEG. C / 1320 DEG. C, E: 75 DEG. C / 1000 DEG. C, J: 63 DEG. C / 950 DEG. C., K: 63 DEG. C. / 1370 DEG. C |
Housing |
|
EG12 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT1007 |
|
G438-0001 |
|
Potentiometer Input Field Configurable Signal Conditioner, 9 - 30V DC |
|
Yes |
|
648,000 |
Input Type |
|
POT |
Field Configurable Input, Min./Max. Span |
|
100 ohms / 100K ohms |
Housing |
|
EG8 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT1008 |
|
G448 |
|
SLIMPAK SIGNAL CONDITIONER STRAIN GAUGE INPUT |
|
Yes |
|
648,000 |
Input Type |
|
Strain Gauge |
Field Configurable Input, Min./Max. Span |
|
0.5mV/V / 50mV/V, Adjustable Excitation 1-10VDC, 120 mA |
Housing |
|
EG12 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT1009 |
|
G468-0001 |
|
AC Input Field Configurable Isolator, 9 - 30V DC |
|
Yes |
|
648,000 |
Input Type |
|
AC Voltage |
Field Configurable Input, Min./Max. Span |
|
100mVAC . 250VAC |
Housing |
|
EG8 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT1011 |
|
G478-0001 |
|
Pulse/Frequency Input Field Configurable Isolator, 9 - 30V DC |
|
Yes |
|
648,000 |
Input Type |
|
Frequency |
Field Configurable Input, Min./Max. Span |
|
2Hz / 10Khz. |
Housing |
|
EG8 |
Field Configurable Output Type |
|
DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA) |
ACT03 |
|
MD03 |
|
OPTIONAL TS35 x 7.5 DIN Rail (2 meters) FOR Ultra SlimPak¢ç Series |
|
Yes |
|
108,000 |
ACT031 |
|
MB03 |
|
OPTIONAL End Bracket for MD03 FOR Ultra SlimPak¢ç Series |
|
Yes |
|
12,960 |
ACT905 |
|
G905 |
|
OPTIONAL 24VDC Power Supply (0.5 Amp) FOR Ultra SlimPak¢ç Series |
|
Yes |
|
334,800 |
ACT915 |
|
H915 |
|
OPTIONAL 24VDC Power Supply (2.3 Amp) FOR Ultra SlimPak¢ç Series |
|
Yes |
|
388,800 | | |