(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

ACT1002 DC Input Field-configurable Dual Limit-alarm

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:ACT1002
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Action Instruments has pioneered wide-ranging, field configurable instrument design for over 12 years.
Action Instruments has pioneered wide-ranging, field configurable instrument design for over 12 years. The Ultra SlimPak Series utilizes ASIC and microprocessor based technologies to provide 1800VDC isolation and wide ranging adjustments for easy, accurate, discrete signal conditioning. The power supply of the Ultra SlimPak will accept any DC source between 9 and 30VDC, (except G448, 18-30VDC) typically a 12 or 24VDC supply is used.

The value of a field configurable instrument is that it allows the user to easily set the instrument for their specific or even custom I/O range. This flexibility can reduce spare parts inventory or increase the efficiency of the process by maximizing resolution in critical process measurements.

Limit Alarms
Limit Alarms are setpoint controllers that regulate industrial processes, discrete, batch or continuous. Alarms are indicators of problems, be they production line faults, process upsets, equipment failures or control system abnormalities.

Signal Conditioners
Signal Conditioners amplify and condition weak signals generated by process sensors. They send signals longer distances without being degraded by electrical noise. They are used to drive devices such as indicators, alarms, controllers, computer interfaces and other process instrumentation.

ASIC Reliability - Lifetime Warranty
Action Instrument¡¯s exclusive analog ASIC design increases reliability by reducing components and interconnections up to 70%. Every Ultra SlimPak is backed by a Lifetime Warranty.

 
Features
  • Easy Field-Configurable Input Ranges
  • Covers all Major Input Types: AC/DC Voltage or Current, RTD, Thermocouple, Strain Gauge, Frequency and Potentiometer
  • Ultra Slim Housing Mounts on DIN Rail for High Density Installations
  • Limit Alarm and Signal Conditioner Models
  • Flexible Power Supply Accepts 9 to 30VDC
  • ASIC Technology for High Reliability
  • Lifetime Warranty
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
ACT1002   G108-0001   DC Input Field-configurable Dual Limit-alarm, 9 - 30V DC   Yes   604,800
Input Type   DC Volt, DC Current
Field Configurable Input, Min./Max. Span   10mV/200V*, 1mA/100mA* - * Bipolar switch for +/- 100% span
Housing   EG12
Field Configurable Output Type   Alarm (Dual SPDT Relay), 1 Relay per Set Point
ACT1004   G118-0002   RTD Input, Wide Ranging Limit Alarm, Dual Trip, SPDT Relays, 9 - 30V DC   Yes   604,800 
ACT1006   G128-0001   TC Input, Wide Ranging, Limit Alarm, Dual Trip, SPDT Relays, 9 - 30V DC   Yes   604,800 
ACT1010   G168-0001   AC Input, Wide Ranging, Limit Alarm, Dual Trip, SPDT Relays, 9 - 30V DC   Yes   604,800 
ACT1001   G408-0001   DC Input Field Configurable Isolator, 9 - 30V DC   Yes   561,600 
Input Type   DC Volt, DC Current
Field Configurable Input Type Min/Max Span   10mV/100V, 1mA/100mA
Housing   EG8
Field Configurable Output Type   DC Voltage (0-5V, 0-10V) DC Current (0-1mA, 0-20mA, 4-20mA)
ACT1012   G408-1001   ¡¡ ¡¡ Yes   561,600 
DC Input, Wide Ranging, Isolated Conditioner, Field Configurable DC Bipolar Output, 9 - 30V 
ACT1003   G418-0001   RTD Input, Field Configurable Isolator, 9 - 30V DC   Yes   648,000 
Input Type   RTD
Field Configurable Input, Min./Max. Span   Platinum RTD, Copper RTD -200 Deg. C / -600 Deg. C
Housing   EG12
Field Configurable Output Type   DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA)
ACT1005   G428-0001   T/C Input Field configurable Isolator, 9 - 30V DC   Yes   648,000 
Input Type   Thermocouple
Field Configurable Input, Min./Max. Span   B: 250 DEG. C / 1320 DEG. C, E: 75 DEG. C / 1000 DEG. C, J: 63 DEG. C / 950 DEG. C., K: 63 DEG. C. / 1370 DEG. C
Housing   EG12
Field Configurable Output Type   DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA)
ACT1007   G438-0001   Potentiometer Input Field Configurable Signal Conditioner, 9 - 30V DC   Yes   648,000 
Input Type   POT
Field Configurable Input, Min./Max. Span   100 ohms / 100K ohms
Housing   EG8
Field Configurable Output Type   DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA)
ACT1008   G448   SLIMPAK SIGNAL CONDITIONER STRAIN GAUGE INPUT   Yes   648,000 
Input Type   Strain Gauge
Field Configurable Input, Min./Max. Span   0.5mV/V / 50mV/V, Adjustable Excitation 1-10VDC, 120 mA
Housing   EG12
Field Configurable Output Type   DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA)
ACT1009   G468-0001   AC Input Field Configurable Isolator, 9 - 30V DC   Yes   648,000 
Input Type   AC Voltage
Field Configurable Input, Min./Max. Span   100mVAC . 250VAC
Housing   EG8
Field Configurable Output Type   DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA)
ACT1011   G478-0001   Pulse/Frequency Input Field Configurable Isolator, 9 - 30V DC   Yes   648,000 
Input Type   Frequency
Field Configurable Input, Min./Max. Span   2Hz / 10Khz.
Housing   EG8
Field Configurable Output Type   DC Voltage (0-5V, 0-10V), DC Current (0-1mA, 0-20mA, 4-20mA)
ACT03   MD03   OPTIONAL TS35 x 7.5 DIN Rail (2 meters) FOR Ultra SlimPak¢ç Series   Yes   108,000 
ACT031   MB03   OPTIONAL End Bracket for MD03 FOR Ultra SlimPak¢ç Series   Yes   12,960 
ACT905   G905   OPTIONAL 24VDC Power Supply (0.5 Amp) FOR Ultra SlimPak¢ç Series   Yes   334,800 
ACT915   H915   OPTIONAL 24VDC Power Supply (2.3 Amp) FOR Ultra SlimPak¢ç Series   Yes   388,800