This portable instrument brings to process QC efficient evaluation of Orange Peel & DOI.
WAVE-SCAN DOI

This portable instrument brings to process QC efficient evaluation of Orange Peel & DOI. A laser beam scans the specimen at 60¢ª over a defined length and collects the optical profile. In order to simulate the human eyes resolution, orange peel structures are divided into different levels, within a "spectrum" ranging from 0.1 to 30 mm wave lengths. In addition, a CCD camera detects at 20¢ª the ultra-short waves which cause surface "dullness", related to the DOI measurements. Data is transferred to the powerful Auto-chart software for futther analysis and processing.

Features
¡Ü Optimal correlation to the visual perception of Orange peel & DOI
¡Ü Output of Long Waves & Short Waves, and DOI
¡Ü Independent of paint system and refractive index
¡Ü Reliable measurements on test panels or curved parts
¡Ü Suitable for solid and metallic coatings
¡Ü One-hand operation, self calibration
¡Ü User-defined sampling procedure
¡Ü Memory 599 values with zone identification
¡Ü Data analysis & management with Auto-chart software
¡Ü Standard package: Instrument, certified reference tile, protective holder, Auto-chart software & PC cable, operating manual, 4 ¡¿ AA 1.5V batteries, and carrying case.

Auto-chart software
¡Ü Instrument programming:
- object identification: car model, colour, paint line
- definition of measurement sequence and zones identification
¡Ü Analysis with Excel¢â and Access¢â:
- trend graph, products comparison, history, structure "spectrum"

Performance
¡Ü Structure spectrum (mm):      dullness: <0.1, Wa: 0.1-0.3,
Wb: 0.3-1, Wc: 1.0-3.0, Wd: 3.0-10, Wc: 10-30
¡Ü DOI, Long wave, Short wave ranges: 0-100
¡Ü Repeatability: 4%, Reproducibility: 6%
¡Ü Scan length: 50, 100, 200 mm
¡Ü Resolution 375 measurement points/cm
¡Ü Object curvature: >1m radius.


Ordering references
WAVE-SCAN DOI
BG4816 Wave-Scan DOI
OPTIONAL ACCESSORIES
BG4401 USB Adaptor
BG4817 Reference Tile to check performance (certified)
BG4825 Crystal clear tape for low gloss surfaces