(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

IR-100 Gamma Camera

½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

The IR-100 Gamma Ray Exposure Device can contain 120 curies of Iridium 192

The IR-100 Gamma Ray Exposure Device can contain 120 curies of Iridium 192 with a rediation level of only 25 mR/HR at six inches from the device surface. Unit weight is apporoximately 49 lbs. Construction consists of all welded stainless steel with inert uranium shielding. Packaging meets all US Nuclear Regulatory Commission specification for radiographic exposure devices.

The IR-100 is operated by a crank mechanism which drives a control cable to move the radiographic source through guide tubes to make an exposure. The unit features a unique safety source lock that meets the latest industry requirements. It serves as an extra check on correct operator procedures, and helps prevent accidental exposure of the operator to radiation. Safety features and specifications include:

¡Ü The lock cannot be accidentally locked while the source is out of the exposure device.
¡Ü The key cannot be removed from the lock unless the source is in the safe-locked position.
¡Ü The source remains locked even though the key lock barrel is removed for cleaning purposes.
¡Ü The unique indicator plate verifies the safety latched position and the "ready to operate" position.
¡Ü The pigtail cannot be pulled completely through the lock on its return to the exposure device.
¡Ü The pigtail cannot be disconnected unless the source is in the locked position.
¡Ü The locked pigtail connector can be rotated to aid in connection to the control cable link.
¡Ü Source guide tubes are normally supplied with thread configuration to ensure safe connections.
¡Ü Source guide tubes are available in two thread configurations, both fine and course as well as snap coupling style.
¡Ü Drive assemblies are available with pistol grip as standard equipment.

Gamma Camera IR-100

Part# Product Description Unit Unit Price
IR-100 Gamma Camera Each 12,710,000 ¿ø

Gamma Camera IR-100P
with 25ft Pistol Grip 1x7ft Source Tube 2x7ft Source tube
Part# Product Description Unit Unit Price
IR-100P IR-100 Gamma Camera with Pistol Grip Each 15,246,000 ¿ø

Gamma Camera IR-100R
with 25ft Reel Drive 1x7ft Source Tube 2x7ft Source tube
Part# Product Description Unit Unit Price
IR-100R IR-100 Gamma Camera with Reel Grip Each 15,972,000 ¿ø

IRIDIUM 192 SOURCES
Part# Product Description Unit Unit Price
CU50 Iridium 192 - 50 Curie Source Each 1,910,000 ¿ø
CU60 Iridium 192 - 60 Curie Source Each 2,105,000 ¿ø
CU70 Iridium 192 - 70 Curie Source Each 2,312,000 ¿ø
CU75 Iridium 192 - 75 Curie Source Each 2,433,000 ¿ø
CU80 Iridium 192 - 80 Curie Source Each 2,554,000 ¿ø
CU85 Iridium 192 - 85 Curie Source Each 2,675,000 ¿ø
CU90 Iridium 192 - 90 Curie Source Each 2,796,000 ¿ø
CU95 Iridium 192 - 95 Curie Source Each 2,917,000 ¿ø
CU100 Iridium 192 - 100 Curie Source Each 3,038,000 ¿ø