Features
  • Simulate RTD Temperature Outputs
  • Several RTD curves available - Plantinum, Cooper & Nickel
  • Guaranteed to work woth all pulsed instruments
  • Also compatible with devices using excitation currents like PLCs, DCS, Recorders and others
  • Works with a variety of transmitters including Rosemount & Honeywell models
 
 
SPECIFICATIONS
Display

¡¡

Backlit, 100mm, Color, 1/4 VGA transmissive display perfect for most indoor environments
Dimensions Front panel: 135 x 240mm; Depth: 245mm
Weight 4kg
Power Rechargeable Battery, life 10 hours typical with backlight
Wavelength 850nm¡¾ 20nm (Loss calibrated to 850nm)
Pulse Width 4 nanosecond (0.4 meter)
Fiber types 62.5um or 50um; multimode graded index
Max. Fiber Length 2km
Resolution Fresnel events <1m apart (¡¾ meter location accuracy)
Dynamic Range >13dB of fiber loss (256 averages where S/N = 1)
Group Index User-adjustable between 1.2 – 2.5
Event/ Attenuation Dead-zone <1m / <4m.
(As with all OTDRs, deadzone parameters are very dependent on the event reflectance. The Telcordia definition is used.)
 Connection is made to the unit using an IEC or TIA compliant mode-conditioning patchcord box fitted with an SC connector. Connection from the patchcord box to the fiber being tested is through a (user specified) Sc FC or ST connector.

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
PR5101   510-Pt100-1   Pt100 Single RTD Curve (alpha = 1.3850)   Yes   605,880
PR5102   510-Pt100-2   Pt100 Single RTD Curve (alpha = 1.3902)   Yes   605,880
PR5103   510-Pt100-3   Pt100 Single RTD Curve (alpha = 1.3916)   Yes   605,880
PR5104   510-Pt100-4   Pt100 Single RTD Curve (alpha = 1.3926)   Yes   605,880
PR5105   510-Cu10   Cu10 Single RTD Curve   Yes   Call 031-777-1588