ÇöÀçÀ§Ä¡ : Home >
PROVA 6830 3»ó Àü·ÂºÐ¼®±â (3000A)
|
TES-6830+6801 Power and Harmonics Analyzer (100A) |
TES-6830+6802 Power and Harmonics Analyzer (1000A) |
TES-6830+3007 Power and Harmonics Analyzer (3000A) |
|
|
|
- Analysis for 3P4W, 3P3W, 1P2W, 1P3W
- True RMS Value (V 123 and L 123 )
- Active Power (W, KW, MW, GW)
- Apparent and Reactive Power (KVA, KVAR)
- Power Factor (PF), Phase Angle (¥Õ)
- Energy (WH, KWH, KVARH, PFH)
- Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
- Display of 35 Parameters in One Screen(3P4W)
- Programmable CT (1 to 600) and PT (1 to 3000) Ratios
- Display of Overlapped Voltage and Current Waveform
- 2.4M Memory with Programmable Interval (1 to 6000 seconds, 17000 Records for 3P4W System)
- Output of Waveform, Power Parameters and Harmonics at Command
- Large Dot Matrix LCD Display with Backlight
- Average Demand (AD in W, KW, MW)
- Maximum Demand (MD in W, KW, MW) with Programmable Period
- Harmonic Analysis to the 99th Order
- Display of 50 Harmonics in One Screen with Waveform
- Display of Waveform with Peak Values (1024 Samples/Period)
- Analysis of Total Harmonic Distortion (%THD-F)
- Graphic Phasor Diagram with 3 Phase System Parameters
- Capture 28 Transient Events (Time + Cycles) with Programmable Threshold(%)
- 3 Phase Voltage Unbalance Ratio (VUR)
- 3 Phase Voltage Unbalance Factor (d0%, d2%)
- Calculated Unbalance Current through Neutral Line (In)
- Optical isolated USB Interface
- Built-in Timer and Calendar for Data Logging
- Conductor Size: -Model 6801 30mm(approx) -Model 6802 5
- 55mm(approx),64*24mm(bus bar) -Model 3007 170mm(approx)
|
|
|
* Please refer to users manual for more detailed and up-to-date description of specification | |
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1) |
Range |
Resolution |
Accuracy of Readings |
6800+6801 |
6800+6802 |
6800+3007 |
5.0 – 999.9W |
0.1W |
¡¾1% ¡¾ 8dgts |
¡¾1% ¡¾ 8dgts |
¡¾1% of VA Range ¡¾8dgts |
1.000 – 9.999 KW |
0.001 KW |
¡¾1% ¡¾ 8 dgts |
¡¾1% ¡¾ 8 dgts |
¡¾1% of VA Range ¡¾8dgts |
10.00 – 99.99 KW |
0.01 KW |
¡¾1% ¡¾ 8 dgts |
¡¾1% ¡¾ 8 dgts |
¡¾1% of VA Range ¡¾8dgts |
100.0 – 999.9 KW |
0.1 KW |
¡¾1% ¡¾ 8dgts |
¡¾1% ¡¾ 8dgts |
¡¾1% of VA Range ¡¾8dgts |
1000 – 9999 KW |
1 KW |
¡¾1% ¡¾ 8dgts |
¡¾1% ¡¾ 8dgts |
¡¾1% of VA Range ¡¾8dgts |
0.000 – 9.999MW |
0.001MW |
– |
¡¾1% ¡¾ 8 dgts |
¡¾1% of VA Range ¡¾8dgts | |
AC Current( 50 or 60Hz, Auto Range£¬True RMS£¬Crest Factor<4£¬CT=1)¡¡ |
¡¡ |
Range |
Resolution |
Accuracy of Readings |
6800+6801
(Overload Protection AC200A) |
0.050 – 9.999A |
0.001A |
¡¾0.5% ¡¾ 5dgts |
10.00 – 60.00A |
0.01A |
¡¾0.5% ¡¾ 5dgts |
60.00 – 99.99A |
0.01A |
¡¾1.0% ¡¾ 5dgts |
6800+6802
(Overload Protection AC2000A) |
0.04 – 10.00A |
0.01A |
– |
0.4A – 100.0A |
0.1A |
¡¾0.5% ¡¾ 5dgts |
4.0 – 1000.0A |
1A |
¡¾0.5% ¡¾ 5dgts |
6800+ 3007
(Overload Protection AC3500A) |
4 – 300A |
0.1A |
¡¾1% of Range ¡¾5dgts |
300.0 – 999.9A |
0.1A |
¡¾1% of Range ¡¾5dgts |
1000 – 3000A |
1A |
¡¾1% of Range ¡¾5dgts | |
AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4) |
Range |
Resolution |
Accuracy of Readings |
Range |
Resolution |
Accuracy of Readings |
4.0V – 500.0 (Phase to Neutral) |
0.1V |
¡¾ 0.5% ¡¾ 5dgts |
4.0V –600.0V (Phase to phase) |
0.1V |
¡¾ 0.5% ¡¾ 5dgts | |
Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V) |
Range |
In Percentage |
In Magnitude |
Resolution |
Accuracy of readings |
Resolution |
Accuracy of readings |
1 – 20 th |
0.1% |
¡¾2% |
0.1 V |
¡¾2% ¡¾0.5V |
21 – 49 th |
4% of reading ¡¾2.0% |
4% of reading ¡¾0.5A |
50 – 99 th |
6% of reading ¡¾2.0% |
6% of reading ¡¾0.5A | |
Harmonics of AC Current in % and in Magnitude
Model 6800+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range) |
Range |
In Percentage |
In magnitude |
Resolution |
Accuracy of reading |
Resolution |
Accuracy of reading |
1 – 10 th |
0.1% |
¡¾0.2 of reading ¡¾1% |
0.1mA / 0.1A |
¡¾0.2% of reading ¡¾7dgts |
11 – 20 th |
¡¾2% of reading ¡¾1% |
¡¾2% of reading ¡¾7dgts |
2 1 – 50 th (A range) |
¡¾5% of reading ¡¾1% |
¡¾5% of reading ¡¾7dgts |
2 1 – 50 th (mA range) |
¡¾10% of reading ¡¾1% |
¡¾10% of reading ¡¾7dgts |
5 1 – 99 th |
¡¾35% of reading ¡¾1% |
¡¾35% of reading ¡¾7dgts | |
Model 6800+6802(1000A);6800+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A) |
Range |
In Percentage |
In Magnitude |
Resolution |
Accuracy of reading |
Resolution |
Accuracy of reading |
1 – 20 th |
0.1% |
¡¾2% |
0.1A(6802) / 0.3A(3007) |
¡¾2% of reading ¡¾0.4A/0.6A |
21 – 49 th |
4% of reading ¡¾2.0% |
¡¾4% of reading ¡¾ 0.4A/0.6A |
50 – 99 th |
6% of reading ¡¾2.0% |
¡¾6% of reading ¡¾ 0.4A/0.6A | |
Total Harmonic Distortion |
Range |
Resolution |
Accuracy(6801) |
Accuracy(6802) |
Accuracy(3007) |
0.0 – 20% |
0.1% |
¡¾1% |
¡¾2% |
¡¾2% |
20 – 100% |
0.1% |
¡¾3% of reading ¡¾5% |
¡¾6% of reading ¡¾1% |
¡¾6% of Range ¡¾1% |
100 – 999.9% |
0.1% |
¡¾10% of reading ¡¾10% |
¡¾10% of reading ¡¾1% |
¡¾10% of Range ¡¾1% | |
Peak Value of Ac Voltage or AC Current ,VT=1 |
Range |
Sampling Time |
Accuracy of reading |
50Hz |
39 ¥ìS |
¡¾5% ¡¾30digits |
60Hz |
33 ¥ìS |
¡¾5% ¡¾30 digits | |
Crest Factor (C.F.) of ACV or ACA ,VT=1 |
Range |
Resolution |
Accuracy of reading |
1.00 – 99.99 |
0.01 |
¡¾5% ¡¾30digits | |
Range |
Resolution |
Accuracy of reading |
45 – 65Hz |
0.1Hz |
0.1Hz | |
Range |
Resolution |
Accuracy of reading |
0.00 – 1.00 |
0.01 |
¡¾ 0.04 | |
Range |
Resolution |
Accuracy of reading |
-180 ¡£ to 180 ¡£ |
0.1 ¡£ |
¡¾ 1 ¡£ | |
Conductor Size (6801) |
30mm (approx.) |
Conductor Size (6802) |
55mm(approx.), 64 X 24mm(Bus Bar) |
Battery Type |
1.5V SUM-3 x 8 |
Display |
Dot Matrix LCD with backlight |
Power Consumption |
140mA (approx.) |
External DC Input |
DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection) |
LCD update rate |
1 times / sec |
No. Of Samples/Period |
1024 |
Operating Humidity |
< 85% relative |
Operating Temperature |
-10¡ÆC to 50¡ÆC |
Storage Humidity |
< 75% relative |
Storage Temperature |
- 20¡ÆC to 60¡ÆC |
Weight(6800) |
1160g |
Weight(6801) |
200g |
Weight(6802) |
600g |
Dimension(6800) |
257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H) |
Dimension(6801) |
210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H) |
Dimension(6802) |
244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H) |
Accessories |
Test leads x 4£¬alligator clips x 4£¬Carrying bag x 1£¬Users manual x 1£¬Batteries 1.5V x 8 | |
| | |
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ |
Æò°¡ |
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ |
´äº¯ |
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
|
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. |