HR9009 Industrial Dual-Block Calibrator

Á¦Á¶»ç : DAVIS
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

The Model 9009 Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.¡¡

The Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 35¡ÆC to 350¡ÆC, while the cold block covers the range -15¡¤¡ÆC to 70¡ÆC. Both blocks are controlled by a precision temperature controller.

 
Features
  • Temperatures from -15¡ÆC to 350¡ÆC in one unit
  • Two wells in each block for simultaneous comparison calibrations
  • Rugged, lightweight, water-resistant enclosure
  • Controlled by precision temperature controller
 
SPECIFICATIONS
 

Hot Block

Cold Block

Range 50¡ÆC to 350¡ÆC (122¡ÆF to 662¡ÆF) -15¡ÆC to 70¡ÆC (5¡ÆF to 230¡ÆF) in 23¡ÆC ambient
(-8¡ÆC with hot block at 350¡ÆC) 18¡ÆF @ 662¡ÆF
Accuracy ¡¾0.6¡ÆC ¡¾0.2¡ÆC
Stability ¡¾0.05¡ÆC ¡¾0.05¡ÆC
Well-to-Well Uniformity ¡¾0.1¡ÆC ¡¾0.1¡ÆC
Heating Times 10 minutes from 25¡ÆC to 350¡ÆC 15 minutes from 25¡ÆC to 70¡ÆC
Cooling Times 30 minutes from 350¡ÆC to 100¡ÆC 16 minutes from 25¡ÆC to -15¡ÆC
Stabilization Times 8 minutes 8 minutes
Well Depth 4 inches (101.6 mm) 4 inches (101.6 mm)
Removable Inserts
Two 1/4" (6.4 mm) and two 3/16" (4.8 mm) inserts included; see Ordering Information for other available inserts
Power
115 VAC (¡¾10%), 50/60 Hz; 230 VAC (¡¾10%), 50/60 Hz; specify
Size
7" H x 10.5" W x 9.75" D (178 x 267 x 248 mm)
Weight
10 lb. (4.5 kg)
Certification Includes 7-point, NIST-traceable certificate of calibration with data at the following points: 50¡ÆC, 100¡ÆC, 150¡ÆC, 200¡ÆC, 250¡ÆC, 300¡ÆC, and 350¡ÆC  Includes 7-point, NIST-traceable certificate of calibration with data at the following points: -8¡ÆC, 0¡ÆC, 25¡ÆC, 50¡ÆC, 75¡ÆC, 100¡ÆC, and 70¡ÆC

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
HR9009   9009   INDUSTRIAL DUAL-BLOCK CALIBRATOR   Yes   6,609,600
HR31020   3102-0   OPTIONAL BLANK INSERT FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   128,520
HR31021   3102-1   OPTIONAL INSERT, 1/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31022   3102-2   OPTIONAL INSERT, 1/8" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31023   3102-3   OPTIONAL INSERT, 3/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31024   3102-4   OPTIONAL INSERT, 1/4" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31025   3102-5   OPTIONAL INSERT, 5/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31026   3102-6   OPTIONAL INSERT, 3/8" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31027   3102-7   OPTIONAL INSERT, 7/16" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880

 

HR31028   3102-8   OPTIONAL INSERT, 5/32" FOR MODEL 9102 DRY-WELL CALIBRATOR FOR Industrial Dual-Block Calibrator   Yes   146,880