The ISOCAL 6 is the only calibration system in the world (Patent application 9900158.8) to offer you six calibration baths in one product. It is a complete temperature calibration laboratory in one simple easy-to-use package. It is designed to expand with you to fulfill all of your future calibration needs while giving you the flexibility to meet your current budgetary demands.

The ISOCAL 6 can calibrate temperature sensors absolutely or by comparison. It will calibrate contact and non-contact sensors including infrared thermometers, surface sensors, mercury in glass thermometers, as well as thermocouples, RTDs, and thermistors of any shape.

There are three different models covering a total temperature range of -65¡ÆC below ambient to 250¡ÆC. The ISOCAL 6 has interchangeable inserts to give you the most flexible calibration system ever, with unprecedented accuracies from ¡¾0.001¡ÆC with fixed point apparatus.

 
SPECIFICATIONS

Temperature Range

SERIES V -55¡ÆC below ambient to 140¡ÆC (284¡ÆF)
SERIES C Ambient to 250¡ÆC (482¡ÆF)
SERIES E -65¡ÆC below ambient to 140¡ÆC (284¡ÆF)
Stabilities over 30 minutes
Metal Block Bath ¡¾0.03¡ÆC
Stirred Liquid Bath ¡¾0.025¡ÆC
Ice/Water Bath ¡¾0.001¡ÆC
Black Body Source ¡¾0.3¡ÆC
Surface Sensor Calibrator ¡¾0.5¡ÆC
ITS-90 Fixed Point
Mercury Triple Point ¡¾0.0005¡ÆC at -38.8344¡ÆC
Water Triple Point ¡¾0.00025¡ÆC at 0.01¡ÆC
Gallium Melt Point ¡¾0.00025¡ÆC at 29.7646¡ÆC
Indium Melt Point ¡¾0.0005¡ÆC at 156.59850¡ÆC
Stabilization Time 10 minutes
Calibration Volume 1-3/8" diameter x 6-1/4" deep
Uniformity ¡¾0.018¡ÆC
Controller Resolution 0.1¡Æ
Indicator Resolution 0.1¡Æ to 0.01¡Æ
Indicator Units ¡ÆC, ¡ÆF, ¡ÆK
Overall Dimensions 12" x 7" x 11"
Weight 23 lbs
Power 70V AC or 240V AC (specify)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TT60108   VENUS-2140-B+   ISOCAL 6 , -55¡ÆC below ambient to 140¡ÆC (284¡ÆF), basic version, with RS232 & software   Yes   9,354,420
TT60109   VENUS-2140-S+   ISOCAL 6 , -55¡ÆC below ambient to 140¡ÆC (284¡ÆF), site version, with RS422 & software   Yes   10,463,364
TT6070   CALISTO-2250-B+   ISOCAL 6 , 30¡ÆC to 250¡ÆC (482¡ÆF), basic version, with RS232 & software   Yes   6,607,764

 

TT60111   CALISTO-2250-S+   ISOCAL 6 , 30¡ÆC to 250¡ÆC (482¡ÆF), site version, with RS422 & software   Yes   7,525,764

 

TT60112   EUROPA-3140-S+   ISOCAL 6 , -65¡ÆC below ambient to 140¡ÆC (284¡ÆF), site version, with RS422 & software   Yes   12,668,400
TT60113   ISO6-INS-L   OPTIONAL Standard liquid container for ISOCAL 6 (alcohols, water, or oils) FOR Calibration Laboratory   Yes   541,620

 

TT60114   ISO6-INS-B   OPTIONAL Blackbody target for ISOCAL 6 FOR Calibration Laboratory   Yes   275,400

 

TT60115   ISO6-INS-SK   OPTIONAL Standard surface sensor calibration insert for ISOCAL 6 FOR Calibration Laboratory   Yes   504,900

 

TT60116   ¡¡ ¡¡ OPTIONAL I-Cal Calibration Software FOR Calibration Laboratory   Yes   1,377,000