The Modulogger¢â is a modular, self-contained data logging and alarming system designed for field, production floor and lab data collection. As a self-contained, battery or line-powered, stand-alone unit, the Modulogger can be deployed for reliable data collection of digital and analog inputs, storing them to internal or PCMCIA memory. Easily programmed with HyperWare¢â, the Modulogger Series has extremely powerful processing capabilities for data reduction (averaging, min/max, etc) mathematical manipulation (algebraic, trig, time integrals, etc), as well as unlimited, User-programmable, intelligent data logging capabilities.

The ModuLogger consists of a User-specified stack of ruggedly packaged, plug-together, interface modules. Increasing the functionality of the ModuLogger is easily accomplished with communication options, additional analog or digital inputs (ModuLogger only), LCD display and memory expansion modules to meet your specific application, or build a fully customized system based on the ML-300 system integration product.

The ModuLogger CPU base module contains the system microprocessor, data storage memory, 13 bit Analog to Digital converter, basic User switches and indicators, RS-232 port, and Cold Junction Compensation circuitry. It also includes four alarm outputs (2 relays, TTL and 5V software controllable), four universal analog inputs, and one digital count/event input. The analog inputs are software configurable for 6 thermocouple types, 15 ranges of DC voltage or 7 ranges of DC current (specifications are identical to MLIM-1). Each analog input offers full differential inputs, software programmable configuration, front-end completion circuitry and rugged suppression protection circuitry to insure reliable accurate readings.

The ModuLogger is easily expandable from a family of plug-on modules. Choose from additional analog inputs (isolated or non-isolated), digital I/O, modem communication, PCMCIA memory card interface, User interface/display, battery power and integrated sensor power supply. As modules are added, they stack onto the CPU base module, building a layered instrument to meet your needs. Modules are self-identifying and configurable via the HyperWare software for input type and range within the module¡¯s capability. ModuLogger allows for up to 5 added I/O modules. The ModuLogger is ordered by individual line items so it is recommended to consult Davis technical sales for assistance with specifying ModuLogger components.

The ML-300 system can house either the ModuLogger or the ModuLogger MINI and additional interface modules or ancillary options for a complete data logging solution. Available options include rechargeable Gel-Cell batteries, cellular telephone or RF communications, regulated power supply for sensor excitation, Photovoltaic charging, and an EtherNet connection.

 
Features
  • Two models to choose from: ModuLogger¢â for expandable I/O requirements and MINI for 4 channel applications
  • Expandable to 44+ analog inputs
  • Up to 48+ digital inputs/Alarm outputs
  • Modular design for easy expansion and OEM applications
  • Utilizes revolutionary HyperWare¢â software for graphic programming, communications, data plotting, real-time trending and more
  • Modem option with Pager Alarm Output
  • Low Power; battery or line powered
  • 13 bit ADC or 18 bit with isolated module
  • Full differential, bipolar inputs with 5 uV Resolution
  • Real-Time trending to a PC via modem or RS-232 serial link
  • Download data via RS-232, Cellular phone, RF Modem or EtherNet
 
SPECIFICATIONS

Data Storage Memory

Redundant battery backed up SRAM. Apx 15,000 samples internal, up to 80,000 samples with expanded memory option
A/D Converter 12 bit plus sign (13 bit) SAR converter. Programmable first-order filtering and 50/60 Hz noise rejection options
A/D Converter Accuracy +/-0.1% RDG + 1 bit
Sampling Throughput Rate 150+ Samples per Second (analog input to memory); rate is dependent on number and type of channels and programmed signal processing. Sampling rates are configurable for each channel
Analog Input Channels 4 individually programmable channels of the following analog signal input. Any combination of the following types/ranges can be configured in a Modulogger.
Thermocouple Type J, K, E, T, R, S
Accuracy +/-0.2 to 1.0C depending on range and type (+/- 5C for R and S type)
Cold Junction Compensation (CJC) Range -10 to 60C
CJC Accuracy +/-0.5C
DC Voltage
Full Scale Ranges +/-20 mV, +/-40 mV, +/-50 mV, +/-70 mV, +/-100 mV, +/-200 mV, +/-1V, +/-2 V, +/-5 V, +/-10 V, +/-30 V
Accuracy +/-0.3% F.S.
Common Mode Range 3.5 VDC, Full Differential Input
Input Resistance >2.5 M for 5, 10 and 30 VDC; >10M for all other ranges
DC Current
Full Scale Ranges +/-400 uA, +/-1.2 mA, +/-2.5 mA, +/-11 mA, +/-22 mA
Accuracy +/-0.3% of Rdg
Input Resistance 100 ohms (all current ranges)
Digital Input One General Purpose Digital Input Channel. User programmable for Event or high-speed Counter applications. Contact closure or TTL driven signal input (15VDC max)
Outputs
2 Low-voltage relays; 500 mA rated
1 Current limited TTL digital outputs
1 100 mA 5VDC regulated output
External power Terminal strip connection for external power source. Accepts 9-32 VDC, 10-26 VAC from any semi-regulated external source
(120 VAC wall adapter is included with Modulogger). Fuse and Transzorb protected
Operating Temp/Humidity -10 to 60C (14 to 140 F) 90% non-condensing Contact factory for extended temperature applications
Enclosure/Dimensions/Weight Dust Sealed. 8.8" W x 4.8" H x 2.2" H (3.8" H with Battery pack attached) 1.5 lbs (3 lbs with battery pack)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
LB02082000   MNL-1   MINI UNIT W/HYPERWARE SFTWARE MOD: MNL-1   Yes   1,826,820
LB02082008   ML-CPU   MODuLOGGER CPU W/15k MEMORY   Yes   2,900,880
LB02082031   Option ML-EXM   OPTIONAL FACTORY INSTALLED OPTION EXPANDS INTERNAL MODULOGGER MEMORY TO 80,000 READINGS FOR Portable Datalogging and Alarming System   Yes   321,300

 

LB02082032   ML-TOP   OPTIONAL TOP COVER PLATE FOR Portable Datalogging and Alarming System   Yes   22,032

 

LB02082017   ML-DISP   OPTIONAL DISPLAY MODULE W/LCD & SWITCHSMOD: ML-DISP FOR Portable Datalogging and Alarming System   Yes   358,020

 

LB02082016   ML-BACK   OPTIONAL BACK COVER PLATE W/NO HOLES FOR Portable Datalogging and Alarming System   Yes   44,064

 

LB02082033   COMBO-PAK-1   OPTIONAL COMBO PACK FOR Portable Datalogging and Alarming System   Yes   523,260

 

LB02082019   ML-BATT   OPTIONAL BATTERY PACK MODULE W/6D CELLSMOD: ML-BATT FOR Portable Datalogging and Alarming System   Yes   156,060

 

LB02082034   MLBATT-PSM2   OPTIONAL BATTERY PACK W/SOFTWARE FOR Portable Datalogging and Alarming System   Yes   431,460

 

LB02082035   MLPSM-2   OPTIONAL SENSOR EXCITATION POWER SUPPLY FOR Portable Datalogging and Alarming System   Yes   260,712

 

LB02082010   MLIM-1   OPTIONAL ANALOG INTERFCE MODULE 4 CHANNOF THERMO MOD: MLIM-1 FOR Portable Datalogging and Alarming System   Yes   642,600

 

LB02082011   MLIM-2   OPTIONAL DIGITAL INTERFCE MODULE 4CHANNOF FREQ MOD: MLIM-2 FOR Portable Datalogging and Alarming System   Yes   642,600

 

LB02082012   MLIM-4   OPTIONAL RESISTANCE INTERFCE MOD 4CHANNOF RTD MOD: MLIM-4 FOR Portable Datalogging and Alarming System   Yes   642,600

 

LB02082014   MLIM-5   OPTIONAL PCMCIA INTERFACE MODULE MOD: MLIM-5 FOR Portable Datalogging and Alarming System   Yes   266,220

 

LB02082015   MLIM-5-144   OPTIONAL MODEM/PCMCIA INTERFCE MODULE MOD: MLIM-5-144 FOR Portable Datalogging and Alarming System   Yes   688,500

 

LB02082036   MLIM-7   OPTIONAL ANALOG INTERFACE MODULE FOR Portable Datalogging and Alarming System   Yes   954,720

 

LB02082013   MLIM-8   OPTIONAL DIGITAL INTERFCE MODULE 8CHANNMOD: MLIM-8 FOR Portable Datalogging and Alarming System   Yes   523,260

 

LB02082037   ML-300   OPTIONAL SYSTEM INTEGRATION PACKAGE FOR Portable Datalogging and Alarming System   Yes   504,900

 

LB02082038   SRB-1   OPTIONAL BATTERY, SEALED GEL-CELL FOR Portable Datalogging and Alarming System   Yes   137,700

 

LB02082039   PSM-2   OPTIONAL SENSOR EXCITATION/LOOP POWER SUPPLY FOR Portable Datalogging and Alarming System   Yes   321,300