TrendReader¢ç allows you to present logged data the way you want. Multiple logged data sets can be displayed and compounded to create new graphs. For added presentation power, TrendReader¢ç lets you add comments, change graph colors, zoom in on specific portions of data, display your data using custom engineering units and print to any Windows compatible printer with ease. TrendReader¢ç even lets you copy/paste your graphs directly into your case reports. If you prefer to use Excel¢ç, Lotus¢ç or other popular spreadsheet programs, data can be exported into several ASCII formats.
User selectable rates from 5 per second to once every 12 hours
Resolution
8 bit (1 part in 256). Can be optimized to the equivalent of 10 bit resolution
Communication
Optical Send/Receive from up to 1" between logger and interface cable (with no obstructions)
Alarm Type
Optical (Red LED)
External Connector
Removable; IP 67 occasional submergence rating (OWL model 100 only)
PC Requirements
IBM PC or 100% compatible
Software Requirements 1. Windows¢ç -- Windows¢ç version 3.1 or later already running with at least 2 MB or RAM memory and 2 MB or hard disk space 2. DOS-MS DOS version 3.0 or later and at least 512 K of RAM memory. TrendReader¢ç for DOS supports a wide range of printers and plotters.
Product Approvals Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE)
Interface Cable Specifications
PC Connector
Female DB 9 pin connector
Logger Connector
Anodized Aluminum optical connecting tube
Cable length
1.8 meters (6 feet)
Internal Temperature Model
Thermistor Type
NTC Thermistor (10K ohms @ 25¡ÆC)
Operating Range
-40 to 85¡ÆC (-40 to 185¡ÆF); 0 to 100% RH
Total Accuracy
¡¾0.5¡ÆC (0.9¡ÆF @ 77¡ÆF). Can be increased by using narrow range feature
Standard Resolution
0.5¡ÆC (0.9¡ÆF) at 25¡ÆC (77¡ÆF). Better than 1¡ÆC (1.8¡ÆF) between -25¡ÆC (77¡ÆF) and 70¡ÆC (158 ¡ÆF). Better than 2.0¡ÆC (3.6¡ÆF) between -40¡ÆC (-40¡ÆF) and -25¡ÆC (-13¡ÆF) Can be increased by using narrow range feature
Submergence Rating
100 m (328') in fresh water
External Temperature Model
Thermistor type
NTC (10K ohms)
Logging Accuracy
¡¾1% of range, probe required
AC Current Model 300
Frequency Ranges
60 Hz - A60FL and A70FL current probes
50 Hz - A65FL and A75FL current probes
Current Ranges
With OWL A60FL and A65FL
current probes 5, 25, 100, 250 Amps
With OWL A70FL and A75FL current probes
0, 50, 250 and 500 Amps
Accuracy
¡¾3% F.S. above 10% range, Probe required
DC Voltage Model 400
Input Range
0 to 38.4 volts max. DC (software selectable ranges available)
Input Impedance
Greater than 100 K ohms
Accuracy
¡¾1% of full scale
DC Current Process Model 500
Input Range
0 to 24 mA max. DC
Input Impedance
100 ohms
Accuracy
¡¾1% of full scale
CAT NO.
MODEL
DEscRIPTION
AVAIL
PRICE
AR72110
OWL-100 01-0050
INFO LOGGER,INTERNAL TEMP
Yes
732,564
AR72111
OWL-200 01-0251
INFORMATION LOGGER, EXTERNAL TEMP
Yes
548,964
AR72112
OWL-300 01-0252
INFORMATION LOGGER, AC CURRENT
Yes
548,964
AR72113
OWL-400 01-0253
INFORMATION LOGGER, DC VOLTAGE
Yes
548,964
AR72114
OWL-500 01-0254
INFORMATION LOGGER, DC CURRENT
Yes
548,964
AR72121
OWL-100
Info Logger, Internal Temperature, Plastic noryl plastic case
Yes
548,964
AR72115
TR-WIN-OWL (01-0070)
OPTIONAL TRENDREADER SOFTWARE (WINDOWS) FOR Information Loggers
Yes
310,284
AR72117
LIC-101 (01-0023)
OPTIONAL COMPUTER INTERFACE CABLE FOR Information Loggers
Yes
181,764
AR72118
OWL-ET-016 (01-0004)
OPTIONAL GENERAL PURPOSE TEMP PROBE -30-200F OWL-ET-016 (01-0004) FOR Information Loggers
Yes
178,092
AR72120
OWL70FL (01-0001)
OPTIONAL AC CURRENT CLAMP 500AMP, 60HZ FOR Information Loggers