PL1487301 1 Channel Recorder

Á¦Á¶»ç : DAVIS
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

These recorders are designed with the latest innovation in recording technology, enclosures and functionality. Finding a place to install this recorder is easy, with its compact 2.5" panel depth and short 1.3" protrusion from the front of the panel. It can be panel or surface mounted. The cutout size is the commonly utilized 12.7" square cutout.
 
Features
  • 1 or 2 trend pen versions
  • 4 digit red LED display
  • High/Low limit capability available
  • Universal Inputs
  • Up to 2 alarms per pen
  • Universal power supply
  • Communications
 
SPECIFICATIONS

Recording

Pen Type Disposable fiber tip
Pen Color Pen 1 - Red
Pen 2 - Green
Chart Size 10 inch
Chart Drive Stepper motor
Chart Rotation User configurable; 8 hour, 12 hour, 24 hour or 7 day
Chart Span Bottom and top of span, -9999 to 9999 units
Inputs
Input Types/Range Type  Range
Thermocouple J 0¡ÆC to 70¡ÆC 0¡ÆF to 1400¡ÆF
K 0¡ÆC to 1360¡ÆC 0¡ÆF to 2500¡ÆF
T -200¡ÆC to 400¡ÆC -330¡ÆF to 750¡ÆF
R 200¡ÆC to 1650¡ÆC 400¡ÆF to 3000¡ÆF
S 200¡ÆC to 1650¡ÆC 400¡ÆF to 3000¡ÆF
RTD 100 ohm -140¡ÆC to 400¡ÆC -220¡ÆF to 750¡ÆF
Platinum  ¡¡
.00385 ohms/ohm/¡ÆC  ¡¡
Current DC 0 to 20mA, 4 to 20mA
Internal 4.7 ohm Shunt Resistor
Voltage DC 0 to 25mV, 0 to 50mV, 10 to 50mV, 0 to 5 V, 1 to 5 V
Input Performance
Performance Under Reference Condition
Measurement Error Type J, K, T, R, S and RTD: ¡¾0.25% of span ¡¾1 degree mA, mV and VDC: ¡¾0.25% of scaled span plus 1 least significant digit
Cold Junction Compensation Error ¡¾0.2¡ÆC @ 25¡ÆC
Cold Junction Compensation Rejection 0.04¡Æ/¡ÆC deviation from 25¡ÆC
Linearization Error expectations

TCs: ¡¾0.25¡ÆC typical, ¡¾0.5¡ÆC worst case with
RTDs: ¡¾0.1¡ÆC typical, ¡¾0.3¡ÆC worst case

Ambient Temperature Error ¡¾0.01% of span per ¡ÆC deviation from 25¡ÆC
Power Requirements
Line Voltage 90-264 VAC, 50/60 Hz
Power Consumption 18 VA Maximum
Construction
Enclosure Injection molded Noryl case and cover with acrylic window
NEMA Rating NEMA 3 standard
Mounting Panel or wall
Overall Dimensions 14" wide x 14" high x 3.8" deep (355.6mm x 355.6mm x 96.5mm)
Panel Cutout 12.7" wide x 12.7" high (322.58mm x 322.58mm)
Panel Depth 2.5" (63.5mm)
Panel Protrusion 1.3" (33.0mm)
Weight 15 lbs maximum
Alarms
Number Up to two process alarms for each of two inputs
Type Process high or low
Limit Device output Optional high/low limits for each input with latching
Normally open output latches open
Red reset button included to the right of the display
Hysteresis Fully adjustable, 0 to 200 units, single sided
Security Alarm setpoint changes can be prohibited
Sensor Fault Action Alarms work normally in "Hi" and "Lo" conditions
Relay Outputs
Relays SPDT, contacts rated 5 amps resistive at 115 VAC, 2.5amps resistive at 230 VAC, 1/8 HP at 230 VAC (singlephase), 250 VA at 115/230

¡¡

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
PL1487301   51000011   1 Channel Recorder NEMA 3 Case with Alarms/Relays   Yes   1,198,908
PL1487311   5700011   2 Channel Recorder NEMA 3 Case with Alarms/Relays   Yes   1,624,860 
PL148732   54020011   1 CH.REC. NEMA 3 CASE W/ALARMS2 RELAY OUTPUTS   Yes   1,551,420
PL148733   54422011   2 CH.REC. NEMA 3 CASE W/ALARMS2 RELAYS OUT PER CH. 54422011   Yes   2,383,128