ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù > ½á¸ÓÄ¿Çà Thermocouple µ¥ÀÌÅͷΰŠData Logger ¿Âµµ°è Thermometer ÀúÇ×Ãø¿Âü RTDs Æ®·£½º¹ÌÅÍ Transmitter¤¤ ¿Âµµ½ë¼ Probes Àû¿Ü¼±¿Âµµ°è Infrared ÇöÀç ºÐ·ù
HR1521 Handheld Thermometer
Features
Reads
PRTs/RTDs to ¡¾0.025¡ÆC and thermistors to ¡¾0.005¡ÆC
Model
1522 logs up to 10,000 readings on-board in multiple data
sets
INFO-CON
connector allows interchangeable use of calibrated probes
INFO-CON
eliminates errors from programming probe data
Reads
ITS-90, DIN 385, Callendar-Van Dusen, Steinhart-Hart, and
YSI 400 thermistor curves
Battery
powered package includes: RS-232 Cable, AC Power Adapter,
One INFO-CON Connector
RTD
accuracy to ¡¾0.025¡ÆC
Thermistor
accuracy to ¡¾0.005¡ÆC
Resolution
to 0.001¡Æ
SPECIFICATIONS
Sensor Type
Pt 25 to Pt 100
Thermistor
Temperature Range
-200 to 962¡ÆC
Sensor Dependant
Resistance Range
0 to 400 ohms
0 to 500K ohms
Characterizations
ITS-90, IEC-751
(DIN '385'), Callendar-Van Dusen
Steinhart-Hart
thermistor polynomial, YSI 400 (2252 ohms)
Temperature
Accuracy (meter only)
-200 to 100¡ÆC: ¡¾0.025¡ÆC
0 to 50¡ÆC: ¡¾0.005¡ÆC
100 to 400¡ÆC: ¡¾0.05¡ÆC
50 to 75¡ÆC: ¡¾0.01¡ÆC
400 to 800¡ÆC: ¡¾0.1¡ÆC
75 to 100¡ÆC: ¡¾0.02¡ÆC
800 to 962¡ÆC: ¡¾0.15¡ÆC
Operating Range
0 to 40¡ÆC
Temperature
Resolution
0.001¡Æ
Measurement Period
1
second
Communications
RS-232
(Model 1522 also includes infrared interface)
Memory
Model 1700 stores
6 readings in "Hold" mode:
Model 1522 logs 10,000 readings in "Auto Log" mode and 100
readings in "Demand Log" mode (memory also holds up to 25 data
labels)
Display
6-digit,
7-segment LCD with 16x1 alphanumeric
Power
Rechargeable
NiMH batteries (AC adapter included)
Size
7.75"
H x 4.2" W x 1.5" D (20 x 11 x 4 cm)
Weight
1 lb.
(0.4 kg)
CAT
NO.
MODEL
DEscRIPTION
AVAIL
PRICE
HR1700
1700
HAND HELD
THERMOMETER
Yes
1,881,900
HR1522
1522
HANDHELD
THERMOMETER W/DATA- LOGGING
Yes
1,881,900
HR56276
5627-6
OPTIONAL
PROBE RTD-100 Ohm 4-WIRE -200 TO 300C
6" FOR Handheld Standards Thermometer
Yes
826,200
HR56279
5627-9
OPTIONAL
PROBE RTD-100 Ohm 4-WIRE -200 TO 300C
9" FOR Handheld Standards Thermometer
Yes
826,200
HR562615
5626-15-X
OPTIONAL
PROBE, 100 Ohm PRT, 15", 661¡ÆC
FOR Handheld Standards Thermometer
Yes
2,882,520
X
= termination. Specify ¡°B¡± = bare wire, ¡°S¡± = Gold Spade Lugs,
¡°D¡± = 5-pin DIN for Tweener Thermometer, ¡°I¡± Info-Con connector
for HR1700 & HR1522 Handheld Thermometer.
HR9321
9321
OPTIONAL
SOFT CARRYING CASE FOR
Handheld Standards Thermometer
Yes
183,600
HR9318
9318
OPTIONAL
Hard carrying case
FOR Handheld Standards Thermometer
Yes
330,480
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.