ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù > ¼öºÐ Moisture ½Àµµ°è Hygrometers ½ÎÀÌÆ®·Î¹ÌÅÍ Psychrometers ±â·Ï°è Recorders º¹ÇÕÀåºñ Combination Units Æ®·£½º¹ÌÅÍ Transmitter ÀεðÄÉÀÌÅÍ Indicators ÇöÀç ºÐ·ù
SU199308 Temperature/Humidity Sensor
Service logger with Temperature Humidity Sensor.With the new dual channel Service Logger in hand
With the new dual
channel Service Logger in hand, all you need to do is attach a
corresponding adapter to measure temperature and humidity.
The back-lit display provides detailed information on selected options
and instrument operations.
If the situation calls for long term information gathering—just
leave the unit at the site for up to 40 days, collect over 4000
measurements on each channel, and store the information in its 16K of
internal memory .
A computer software package is provided to transfer recorded data from
the Service Logger to a computer. Just connect the Service Logger
directly to a regular printer and output the stored information.
Features
Records
data up to 40 days
Prints
data without a computer
View
data ¡°On the Spot¡±
Accessory
sensors customize instrument to fit every application
Alphanumeric
backlit display
SPECIFICATIONS
Recording Times
Up to 40 Days
Primary Power
Source
115 Vac 50/60 Hz
Adapter (220-240 Vac, 50/60 Hz Available)
Back-up Power
Source
9V Alkaline battery
for 24 hours of operation (Not included)
Alternative Power
Source
External power may
be supplied from any 12 VDC source such as automotive, marine or other
battery.
Ambient Operating
Temp. Range
+32 - + 150¡ÆF (0 -
+65¡ÆC)
Memory
16K Non-volatile
memory
Display
Alphanumeric
backlit LCD, 16 Characters x 2 Lines
Printer Interface
parallel centronics
compatible printer port
Dimensions
51/8" x
31/2" (130mm x 89mm x 38mm)
Weight
10 oz (284 Grams)
Software
31/2" Diskette
(Supplied)
All Cables
6 Feet Long
SPECIFICATIONS
Temperature /
Humidity Sensor
Complete
with combination temperature, humidity sensor. Allows for measurement of
temperature, humidity and dewpoint.
Temperature /
Humidity Sensor
Type
4" Plastic
housing for air only, with coiled cable
Temperature Range
-40 ¡ÆF to + 170¡Æ
and (-40¡ÆC to + 75¡ÆC)
Temperature
Accuracy
¡¾ 2¡ÆF (¡¾ 1¡ÆC)
Humidity Range
0 to 100% at + 32¡ÆF
and (0¡ÆC to + 55¡ÆC) Ambient
Humidity Accuracy
¡¾ 2%
Dewpoint Range
+32¡ÆF to + 130¡ÆF
and (0¡ÆC to+ 55 ¡ÆC)
CAT
NO.
MODEL
DEscRIPTION
AVAIL
PRICE
SU199308
SLTH
SERVICE
LOGGER WITH TEMPERATURE HUMIDITY SENSOR
Yes
969,840
SU199313
CC6
OPTIONAL
COMPUTER CABLE FOR
5-in-1 Service Logger
Yes
41,040
SU199314
PC6
OPTIONAL
PRINTER CABLE FOR
5-in-1 Service Logger
Yes
41,040
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.