ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù > ¼öºÐ Moisture ½Àµµ°è Hygrometers ½ÎÀÌÆ®·Î¹ÌÅÍ Psychrometers ±â·Ï°è Recorders º¹ÇÕÀåºñ Combination Units Æ®·£½º¹ÌÅÍ Transmitter ÀεðÄÉÀÌÅÍ Indicators ÇöÀç ºÐ·ù
CT485B-110V-W-AL/N Temperature
Temperature/humidity,with plug-in external sensor,removable for remote location
SPECIFICATIONS
Measurement Inputs: Temperature and humidity, with plug-in external sensor, removable for remote location, 6' extension cable included; 0.02 to 1.20 Vdc signal with voltage input adapter
TEMPERATURE Range: -17 to 49¡ÆC (2 to 120¡ÆF) Accuracy: ¡¾1¡ÆC Sensor: Solid state Response Time: 5 minutes for 63% step change Display Resolution: 1¡ÆC/1¡Æ
HUMIDITY Range: 2 to 98% RH Accuracy: ¡¾3% @25¡ÆC, between 20 and 90% of range (¡¾5% below 20% and above 90% @25¡ÆC) Sensor: resistive polymer. Not recommended for use in corrosive air environments Response Time: 5 minutes for a 30 to 80% step change Display Resolution: 1% RH 2-1/2 digit LCD, 0.5" high; low battery Display Modes: Front panel switchable between ¡ÆC, ¡ÆF and %RH for continuous digital display; max/min storage for both temperature and humidity or flashing to indicate alarm condition
Features
Big 200mm (8") Charts
1, 7, or 32 Day Cycles Selectable
Sensors and Extension Cables Included
Benchtop or Wall Mounting
AC or Battery operation
Electronic Microcontroller-based Instrument
Precise Stepper Motor Drive
2 Programmable Alarm Relays (2 Amp)
Audible Alarm
LCD Display
CAT NO
MODEL
DEscRIPTION
AVAIL
PRICE
CT485B-110V-W-AL/N
¡¡
¡¡
Temperature & Humidity Recorder White
Yes
1,404,000
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.