Complete with probe,rechargeable battery,MIK70 link&analog output cable,DMP74 probe
Then DM70 Hand-Held Dewpoint Meter measures dewpoint accurately in a wide measurement range. DM70 can be used in many industrial spot-checking applications as well as a one-point calibration check for fixed dewpoint transmitters. DM70 is small and lightweight yet rugged and therefore an ideal choice for even the most demanding applications.

DM70 incorporated the advanced DRYCAP® Thin Film Polymer Sensor and auto-calibration software, which corrects possible dry end error and provides long term stability in dry conditions. The probe withstands condensation and also measures directly in pressurized spaces.

DM70 has a truly fast response time. The menu-based interface is easy to use and a graphical LCD display with Datalogger function provides an easy way to handle measurement data.

 
Features
  • DRYCAP® polymer-based sensor provides accuracy, reliability, long-term stability and fast response
  • Unique automatic self-calibration
  • ¡¾ 2%C accuracy down to -58¡ÆF (-50¡ÆC)
  • Data logging and transferring capabilities
  • Multilingual, menu-based interface
  • Numeric and graphical display
  • Sample cell adapter for pressurized air lines
 
SPECIFICATIONS

Hand-Held Dewpoint Meter

Housing materials ABS/PC blend
Storage temperature -40 to 158¡ÆF (-40 to +70¡ÆC)
Storage humidity 0-100% RH non condensing
Total weight 750g
Electromagnetic compatibility Complies with the following standards: EN 61326-1:1997 + Am1:1998, Electrical equipment for measurement, control and laboratory use - EMC requirements - Generic Environment
General
Menu languages English, German, French, Finnish and Spanish
Display LCD with backlight. Graphic trend display of any parameter. Character height up to 16mm
Probe inputs 1 or 2
Power supply Rechargeable NiMH battery pack with AC-POWER or 4xA4 size alkalines, type IEC LR6
Analog output 0 - 1 VDC
Output resolution 0.6 mV
Data interface RS232C
Data-logging capacity 900 - 2700 points with real time
Alarm Audible alarm function
Operating temperature 14¡ÆF to 104¡ÆF (-10 to +40¡ÆC)
Operating humidity non-condensing
Housing classification IP54
Weight 400 g
Battery operation time Continuous use, 48 h typical at + 68¡ÆF (+20¡ÆC), Data logging use up to 30 days
Probe - Measurement variables (Dewpoint)
Measurement range (typical) -76 to +140¡ÆF (-60 to +60¡ÆC)
Accuracy -50 to +60¡ÆC ¡¾ 3.6¡ÆF (¡¾2¡ÆC)
Temperature
Measurement range 14¡ÆF to 140¡ÆF (-10 to +60¡ÆC)
Accuracy at +68¡ÆF (+20¡ÆC) ¡¾0.36¡ÆF (¡¾0.2¡ÆC)
Typical temp. dependence of electronics ¡¾0.005¡ÆC/¡ÆC
Temperature sensor Pt100 IEC751 1/3 class B
ppm volume concentration
Measurement range (typical) 40 to 200,000 ppm
Accuracy at +68¡ÆF (+20¡ÆC) 7.3ppm + 8.3% of reading
Relative Humidity Measurement range 0-100% RH
Accuracy at +68¡ÆF (+20¡ÆC), RH < 10% ¡¾0.025% RH + 8.75% or reading<br> RH > 10% ¡¾0.7% RH + 2% of reading
Measurement environment Temperature: 14¡ÆF to 140¡ÆF (-10 to +60¡ÆC); Pressure: 0 to 20 bar; Sample flow rate: no effect
Probe general
Sensor Probe material (wetted parts): Stainless steel (AISI 316L), Sensor protection: Sintered filter (AISI 316L), Mechanical connection with bonded seal ring (U-seal),Gi/2" ISO228-1 thread,Housing classification:IP65 (NEMA4); Weight: 350 g
KIT includes: Indicator + probe with rechargeable battery and 115 VAC adapter, Link and analog output signal cable, probe, sample cell and quick connector, Carrying case, Certification of calibration traceable to NIST

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
VA239261   DM70KIT   Hand-held dewpoint meter kit   Yes   5,184,000 
Complete with probe, rechargeable battery, MIK70 link & analog output cable, DMP74 probe, sample cell & connector, case