자동로그인
 

  오늘 : 1,622명 
  어제 : 2,181명 
  그제 : 2,449명 
  최대 : 7,056명 
  전체 : 5,164,109명 
현재위치 : Home > 전기 및 전력측정기 > Elcontrol Energy 제품 > 휴대형 전력분석기 Portable Energy Analyzer

Nanovip Plus Mem 휴대형 단상 전력분석기
    · 고객선호도 :
    · 판매가격 : 전화문의

회원가입을 하시면 할인된가격을 보실수 있습니다.
모든가격은부가세별도 입니다.
회원이 되시면 가격변동정보, 신제품, 특판제품, 기술정보등 다양한
뉴스정보를 보내드립니다.
30만원미만은 택배비 3,000원(착불)입니다.
카드결재시 세금계산서 발행 불가합니다.
배송은 평균 2~3일정도 예상됩니다.
                    (0)                     (0)                     (0)
Humidity Sensors FK80J<br>Humidity-Temperature Sensors TFK80J PDF 종합 카다로그

NANOVIPPLUSMEM

Pocket energy and harmonics analyzer with memory

Description


 

The NANOVIP PLUS MEM is a hand-held portable instrument which supplies all the information provided by the NANOVIP base model and NANOVIP PLUS model:

Voltage (V rms), Current (A rms), P.F. Cosj, Active power (W), Reactive power (var), Apparent power (VA), Frequency (Hz), Variations in V, I, W, of the memorized values (MEM function, frozen values of the mean measurements in correspondence with the max. A or W values or the minimum V value (PEAK function), DC measurements with optional Hall effect clamp meters.

As well as all the measurements envisaged by the basic version, the NANOVIP PLUS MEM offers many additional functions the total number of measurements is over 100:

• Active energy (kWh) and reactive energy (kvarh) meters in Standard or Cogeneration version (kWh and positive and negative kvarh meters);

• Total Harmonic Distortion Factor (THD) of V and I in relation to the fundamental and the total rms value;

• V harmonics and the value of Cosj from the 1st to the 24th plus their DC component (i.e. j harmonic) in absolute value and as percentage of the fundamental;

• Crest factor of V and I as absolute value and percentage;

• DC Ripple of V and I as absolute value and percentage of the DC value;

• RS232 serial communications port for connection to PC with choice of settings of: 38.4, 19.2, 9.6, 4.8, 2.4, 1.2, Kbaud

7/8 data bits

1/2 stop bit

no/odd/even parity

 

• NANOVIP PLUS MEM is equipped with an internal 1 Megabyte flash memory (4032 records)

• LCD Display with Backlight. The backlight can be set to DISP ON, DISP OFF, DISP AUT (DISP ON for 10 seconds after a key has been pressed).

• Display of the active power relative to the displayed harmonic

• Setup Restore Command to restore factory settings of the Setup parameters.

• Serial line download on PC of the voltage and current waveforms and of the contains of the internal 1Megabyte memory.

 

These functions are useful for a wide range of applications which include:

• Control and optimization of load electrical consumption levels;

• Analysis of the harmonic distortion caused by non linear loads;

• Prevention of the risk of resonance between banks of power factor correction capacitors and

power supply transformers;

• Verification of the DC ripple (residual ripple of direct current power supply units);

• Acquisition of data on Personal Computer for compilation of graphic and numerical reports on tests on electrical machines and systems.

 
 
 

Technical specifications


 

General specifications:

 

Inputs:

Voltage: (L1,N) max 600 VAC (20 Hz - 600 Hz)

Current: 1 Volt (20 Hz - 600 Hz.)

 

Voltage inputs overload: maximum permitted voltage 825VAC,1.17 KV peak.

 

Current input overload: 5 times Full scale value (a protective device trips when this limit is reached).

 

Number of scales: 3 voltage ranges, 3 current ranges.

 

Automatic scale change: Response time for scale change: 1 sec. The change to the next (higher) scale occurs at 105% of full scale value of the scale activated. The change to the next lower scale occurs at 20% of full scale value of the scale activated.

 

Dimensions: 80 x175 x 32,5 (without cover).

 

Weight of the instrument: 400 gr. including cover and batteries.

 

Weight of the whole kit: 1,6 Kg.

 

Protection level: IP40 (IEC 529)

 

Operating temperature range: -10°C to 50°C

 

Relative humidity range: 20% to 80% R.H.

 

Storage temperature range: -20°C to 60°C

 

Insulation: compliant to VDE 0110 group C for operating voltages

500 VAC

 

Insulation resistance: 500 MOhm between short-circuited input terminals

and the case

 

Insulation voltage between voltage inputs: Test voltage= 2000V for 60 seconds

 

Insulation voltage between voltage inputs and case: Test voltage= 3000V for 60 seconds

 

Reference standards: IEC 348, VDE 0411 class 2, for low voltage circuits

- 600 VAC. IEC 1010 600V CAT III level of pollution 2.

 

EMC reference standards: EN 50081-1, EN50082-2, EN 55022

 

 

Power Supply:

 

Battery type: 1,5V AA alkaline-manganese IEC

LR6, nominal capacity 2700mAh

 

Battery life: 50-60 hours typical; 40-50 hours when

PEAK function is activated.

 

 

Measurement of primary parameters:

 

Measurement method: fixed sampling and A/D conversion

 

Sampling frequency: 1.25 KHz.

 

Number of samples: 250 (200 mS)

 

Measurement rate: 1second in normal operation, 0.4 second in PEAK

mode

 

Zero self-regulation: every minute

 

 

PRIMARY MEASUREMENT ACCURACY

 

Measurement error in environment of 18°C to 25°C (after 10’ warming up):

expressed as ± % Rdg. (reading) + % F.S. (Full Scale) – see tables.

 

Additional measurement error outside this temperature range:

± 0,02% F.S. for each °C outside range.

 

Sensitivity and accuracy of voltage measurements:

Direct input with max voltage = 750 Vrms at Full Scale.

Input voltage peak factor .1,6.

Input impedance .4 M.

 

Sensitivity, Full Scale and voltage accuracy

Rated Range

Sensitivity

Full Scale

S between 20% F.S. and 100% F.S.

37 Vrms

24 mV*

37,0 V

0,5%F.S.+ 0,5%Rdg.

174 Vrms

111 mV

174 V

0,3%F.S.+ 0,3% Rdg.

750 Vrms

480 mV

750 V

0,3%F.S.+ 0,3% Rdg.

 

 

 

 

 

 

(*) the minimum measurable signal is 1 V.

 

Sensitivity and accuracy of current measurement:

Direct input with max. 1 Vrms at Full Scale.

Input current peak factor .1,6

 

Sensitivity, Full Scale and current accuracy

Rated Range

Sensitivity

Full Scale **

S between 20% F.S. and 100% F.S.

50 mV

32 µ V*

50 mV

0,5%F.S.+ 0,5%Rdg.

232 mV

140 µ V

232 mV

0,3%F.S.+ 0,3% Rdg.

1 V

640 µ V

1 V

0,3%F.S.+ 0,3% Rdg.

 

 

 

 

 

(*) the minimum measurable signal is 2 mV.

(**) Full Scales for 50,0 - 232 - 1000 Amp. with 1000 A/1V clamp meters provided

(Error = sum of instrument + clamp meter errors).

Accuracy does not take account of clamp meter error.

 

Voltage and current measurement precision as a function of frequency:

no error over errors specified in tables for signal frequencies in 20-90 Hz range.

 

Measurement of other secondary values:

error is expressed by the formula which defines the value, as a function of V and I.

 
 
 

Measures


 
 

TOTAL

V

·

A

·

KW

·

KVA

·

KVAR

·

+KWH / -KWH

·

+KVARH / -KVARH

·

PF

·

THDF V

·

THDF I

·

CF V

·

CF I

·

HZ

·

 
번호 제목 작성자 작성일 평가점수
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다.
 
* 이 상품을 사용해 보셨다면 사용후기를 써 주십시오.
번호 제목 작성자 작성일 답변
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오.
 
* 이 상품에 대한 궁금한 사항이 있으신 분은 질문해 주십시오.
이 상품과 관련된 상품이 없습니다.
 
회사소개 | 서비스이용약관 | 개인정보취급방침
경기도 성남시 중원구 상대원동 513-15번지 선텍시티B/D 708호
대표 전화 : 031-777-1588 / 팩스 : 031-777-1587 / 개인정보관리책임자 : 관리자
사업자 등록번호 : 116-81-31753 / 통신판매업신고 성남시 제2005-886호
대표 : 홍영화 / 운영자 : 윤상미
Copyright ⓒ 2002 상호 : (주)코린스. All Rights Reserved.
가입사실확인