testo 240 conductivity and temperature measuring instrument with battery and 2 electrode clips
Universal conductivity measuring cell, type 07 mS, highest accuracy up to 200 mS/cm, stainless steel
Set case (plastic)
Á¦Ç°°³¿ä
Testo 240Àº Á¤È®ÇÑ ¿Âµµ ÃøÁ¤±âÀÌÀÚ ¿Ïº®ÇÑ Àüµµ¼º ÃøÁ¤±âÀÔ´Ï´Ù. Testo 240¿¡ »ç¿ëµÈ 4-Æú Àü±Ø ±â¼úÀº Çϼö¿¡¼¿Í °°ÀÌ ÃøÁ¤ °ªÀ» ¿Ö°î½ÃŰ´Â ¹°¸®ÀûÀÎ ÄÚÆÃ Çü¼ºÀ» ¹æÁöÇÏ¿© ÁÝ´Ï´Ù. Àú·ÅÇÑ °øÅë ÃøÁ¤ ¼¿ À¯Çü 07 mS¿Í ½ºÅ×Àη¹½º ½ºÆ¿ Àü±ØÀº ¾ÆÁÖ ³ôÀº Á¤È®µµ¸¦ ÇÊ¿ä·Î ÇÏ´Â ÃÖ´ë 200 mS/cmÀÇ ¾ÖÇø®ÄÉÀ̼ǿ¡ ¾ÆÁÖ ÀÌ»óÀûÀÔ´Ï´Ù. ¾ÈÁ¤µÇ°í Á¤È®ÇÑ À¯Çü 10 mS ÃøÁ¤ ¼¿°ú ³ôÀº ³»¼ºÀÇ Æ¯¼ö ±×¶óÆÄÀÌÆ® ÀçÁú·Î µÈ Àü±ØÀº ÃÖ´ë 300 mS/cmÀÇ ÃøÁ¤½Ã ¿ä±¸µÇ´Â ÃÖ»óÀ§ ·¹º§ÀÇ Á¤È®µµ¸¦ Á¦°øÇÕ´Ï´Ù.
|
|
Á¦Ç°±â´É
½¬¿î »ç¿ë¹ý ´ÜÀÏ ÃøÁ¤ ¼¿À» ÅëÇØ ±¤¹üÀ§ÇÑ ÃøÁ¤ ¹üÀ§¸¦ ¼ö¿ë ´ÜÀÏ Ç÷¯±×-ÀÎ ¿¬°áÀ» ÅëÇÑ mS/cm ¹× 캜 °ß°íÇÑ ¹æ¼ö ¼³°è (IP54) Å« µð½ºÇ÷¹ÀÌ ¿°ºÐ ÃøÁ¤ 4-Æú Àü±Ø ±â¼úÀÇ »ç¿ëÀ¸·Î ¾ÆÁÖ ±ä Àü±Ø ¼ö¸í
|
|
±â¼úµ¥ÀÌÅÍ
±â¼úµ¥ÀÌÅÍ |
testo 240 |
¼¾¼ |
Àüµµ¼º ÃøÁ¤ ¼¿ |
NTC ¼¾¼ |
Calc. parameter |
ÃøÁ¤ ¹üÀ§ |
0 mS/cm ~ 2000 mS/cm |
-50 ~ 150¡É |
+1 ~ 200000mg/l NaCl (calc.) |
Á¤È®µµ |
ÃøÁ¤Ä¡ÀÇ 1%. (Àüµµ¼º) |
¡¾0.5% ofmv (100 ~ 150¡É ¡¾0.2¡É (-25 ~ -74.9¡É) ¡¾0.4¡É (-50 ~ -25.1¡É) ¡¾0.4¡É (+75 ~+ 99.9¡É ) |
¡¾1mV(-999 ~ 0 mV ) ¡¾1mV(0 ~ +999 mV ) ¡¾2mV(-1999 ~ -1000 mV ) ¡¾2mV(+1000 ~ +1999 mV ) |
ºÐÇØ´É |
0.01pH(0~+14pH) |
0.1¡É (-50 ~ +150¡É) |
1mV/l(-1999 ~ +1999mV ) |
µð½ºÇ÷¹ÀÌ |
LCD2 ¶óÀÎ |
ÀÛµ¿¿Âµµ |
0 ~ 40¡É |
º¸°ü ¿Âµµ |
-20 ~ 70¡É (-4 ~ 158¡É ) |
¹åµ¥¸®Å¸ÀÔ |
9V block batery |
¹åµ¥¸®¼ö¸í |
60½Ã°£ |
Å©±â |
168X72X27mm |
¹«°Ô |
170g |
º¸È£ Ŭ·¡½º |
IP54 |
º¸Áõ |
2³â |
| |
Compact conductivity measuring instrument
 |
testo 240 is a complete conductivity measuring instrument and a high standard thermometer combined in one compact, waterproof housing.
Measurement errors caused by high conductivities and deposits on electrodes are avoided thanks to the 4 electrode technology used. The salt level (NaCl) in an aqueous solution can measured directly.
¡Ü Long cell lifetime due to the 4 electrode technology used
¡Ü Extremely wide ranges with only one measuring cell
¡Ü Measures salt (NaCl) level
¡Ü User-friendly operation
testo 240 |
testo 240 conductivity and temperature measuring instrument with battery and 2 electrode clips
Part no. 0560 2404 1,013,000 ¿ø
| |
 The 4 pole electrode technology used here prevents the formation of physical coatings which distort the values measured e.g. sewage
Use of particularly long-term stable precision measuring cell type 10 mS for measurements with |
Suitable probes at a glance |
 |
Part no. |
0650 3023 437,000 ¿ø |
0650 3024 602,000 ¿ø | |
 |
Part no. |
0613 1211 126,000 ¿ø |
0613 7011 182,000 ¿ø |
0613 2211 206,000 ¿ø |
0613 1911 144,000 ¿ø | | Pay less for a set
Conductivity Set 1, Universal |
 |
testo 240 conductivity and temperature measuring instrument with battery and 2 electrode clips
Universal conductivity measuring cell, type 07 mS, highest accuracy up to 200 mS/cm, stainless steel
Set case (plastic)
Part no. 0563 2405
| |
|
Conductivity Set 2, Precision |
 |
testo 240 conductivity and temperature measuring instrument with battery and 2 electrode clips
Precision conductivity measuring cell, type 10 mS, long-term stable, highest accuracy up to 300 mS/cm, graphite
Set case (plastic)
Part no. 0563 2406
| |
Ordering data for Accessories |
Part no. |
Conductivity standard (1413 ¥ìS/cm) 0.01 mol/1 KCL, to calibrate conductivity measuring cells |
0554 2334 31,000 ¿ø |
Glass pipe for laboratory probe |
0554 7072 65,000 ¿ø |
Set case (plastic) for measuring instrument, probes and accessories User-friendly arrangement of measuring instrument and accessories |
0516 0230 103,000 ¿ø |
ISO calibration certificate/Water analysis For conductivity solutions; calibration point 1.413 mS/cm |
0520 0019 64,000 ¿ø |
ISO calibration certificate/Temperature For air/immersion probes, calibration points -18¡ÆC; 0¡ÆC; +60¡ÆC |
0520 0001 204,000 ¿ø |
ISO calibration certificate/Water analysis At 3 conductivity values over the measuring range |
0520 0049 383,000 ¿ø | |
|
Technical data |
Probe type |
Conductivity measuring cell |
NTC |
Calc. parameter |
Meas. range |
0... +2000 mS/cm |
-50... +150 ¡ÆC |
+1... +200000 mg/l NaCl |
Accuracy ¡¾ 1 digit |
¡¾1% of mv (0... +2000 mS/cm) |
¡¾0.5% of mv (+100... +150 ¡ÆC) ¡¾0.2 ¡ÆC (-25... +74.9 ¡ÆC) ¡¾0.4 ¡ÆC (-50... -25.1 ¡ÆC) ¡¾0.4 ¡ÆC (+75... +99.9 ¡ÆC) |
¡¾1.2% of mv (+1...+200000 mg/l NaCl) |
Resolution |
|
0.1 ¡ÆC (-50... +150 ¡ÆC) |
0.1 mg/l NaCl (+1...+200000 mg/l NaCl) |
Display |
LCD, 2 lines |
Resolution: max. 0.1 ¥ìS/cm Temp. compensation, automatic Temp. coefficient: 0 to 5 %/¡ÆC linear Compensation according to non-linear function of natural waters to DIN 38404 from 0 to +50¡ÆC Autom. switching between measuring ranges (conductivity) Auto-OFF function Switches between ¡ÆC/¡ÆF |
Oper. temp. |
0... +40 ¡ÆC |
Storage temp. |
-20... +70 ¡ÆC |
Battery type |
9V block battery |
Battery life |
60 h |
Dimensions |
168x72x27 mm |
Weight |
170 g |
Warranty |
2 years | | | | |
|
|
 | |
 |
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
 |
|
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
 |
|
 |
|
|
 | |
 |
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
 |
|
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
 |
|
 |
|
|
 | |
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. | |
|
|
|