TSI¡¯s VelociCalc¢çPlus Meters simultaneously measure and data log several ventilation parameters
TSI¡¯s VelociCalc¢ç Plus Meters simultaneously measure and data log several ventilation parameters using a single probe with multiple sensors. Based on the model, these hand-held instruments measure velocity, temperature, differential pressure and humidity. All versions calculate volumetric flowrate. The Model 8386 also performs dew point, wet bulb temperature and heat flow calculations.
 
Features
  • Flowrate feature makes simple calculations of volumetric flowrate when the user inputs the duct shape and size, K factor or horn size
  • Velocity measurements are made from the thermal sensor or a Pitot tube
  • Automatic conversion between actual and standard velocity readings
  • Direct calculation of dew point and wet bulb temperature — no psychrometric chart needed (Model 8386 only)
  • Heat flow function calculates heat transferred after a heating or cooling element (Model 8386 only)
  • Back-lit display is easy to read in poor lighting conditions
  • 40 inch telescoping probe with etched length marks to make duct traverse measurements easier
  • Optional articulating probe available
  • Optional portable printer provides hard copy documentation of your measurements
Data Logging Capabilities
  • Data logging ability allows user to log 1394 samples with a time and date stamp
  • Simultaneously records all parameters available in each model
  • Single point and continuous data logging modes to fit your application
  • Data can be reviewed on-screen, printed or downloaded to a computer spreadsheet program
  • TSI downloading software permits easy transfer of data to a computer
  • Statistics function displays average, maximum and minimum values, and the number of recorded samples
 
FEATURES
 

TS8384

TS8385

TS8386

Velocity

Volumetric Flowrate

Temperature

Differential Pressure

 

Thermal/Pilot

 

Humidity

 

 

Dew Point

 

 

Wet Bulb Temperature

 

 

Heat Flow Calculations

 

 

Datalogging/Downloading

Statistics/Review Data

Density Correction Factor

Variable Time Constant

Printer Output

NIST Calibration Certificate


SPECIFICATIONS

Models TS8384(A), TS8385(A) and (TS8386A)

 Velocity From Thermal Sensor (all models)
Range 0 to 9,999 ft/min (0 to 50 m/s)
Velocity From a Pitot Tube (Models TS8385(A) and TS8386(A)
Range 250 to 15,500 ft/min (1.27 to 78.7 m/s)
Volumetric Flowrate (all models) a function of velocity, pressure, duct size, and K factor
Duct Size (all models) 1 to 250 in. in increments of 0.1 in.
(1 to 635 cm in increments of 0.1 cm)
Static/Differential Pressure -5 to +15 in. H2O (-9.3 to +28.0 mmHg, or
(Models TS8385(A) and TS8386(A) -1245 to +3735 Pa)
Instrument Temperature Range
Operating (Probe TS8384 (A) and TS8385 (A) 0 to 200¡ÆF (-17.8 to 93.3¡ÆC)
Operating (Electronics) 40 to 113¡ÆF (5 to 45¡ÆC)
Relative Humidity (Model TS8386(A) only) 0 to 95% rh
Wet Bulb Temperature (Model TS8386(A) 40 to 140¡ÆF (5 to 60¡ÆC)
Dewpoint (Model TS8386(A) only) 5 to 120¡ÆF (-15 to 49¡ÆC)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TS8384   8384   VELOCICALC PLUS W/DATA LOGGING   Yes   2,732,400 
TS8384A   8384A   VELOCICALC PLUS W/DATA LOGGINGW/ARTICULATING PB.   Yes   3,056,400

 

TS8386   8386   VELOCI CALC PLUS W/DATA LOGGING   Yes   3,996,000 
TS8386A   8386A   VELOCICALC PLUS W/DATA LOGGINGW/ARTICULATING PB.   Yes   4,309,200

 

TS8385   8385   Velocicalc¢â Plus with Data Logging   Yes   3,477,600
TS8385A   8385A   Velocicalc¢â Plus with Data Logging   Yes   3,790,800
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ