TS33103 High Accuracy Mass Flowmeter

Á¦Á¶»ç : DAVIS
Á¦Ç°¹øÈ£:TS33103
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

This fast response is ideal for closed-loop control systems and integrated volume measurements.
Fast 4 millisecond response ensures accuracy in fluctuating flows. This fast response is ideal for closed-loop control systems and integrated volume measurements. Pressure and temperature measurements are also extremely fast.

A flowmeter specified as ¡¾2 percent of Full Scale is most accurate at full scale. If full scale is 300 L/min, then the uncertainty for all readings is ¡¾6 L/min. The Model 4040 and 4140 are specified as ¡¾2 percent of Reading and have an uncertainty of ¡¾2 percent of the actual reading from full scale all the way down to a specified lower limit. The Model 4040 and 4140 flowmeters, therefore, provide dependable accuracy over a wide range of flowrates. One of these flowmeters covers the same range as three or more "percent of full scale" devices, with better accuracy at all points.

Low pressure drop minimizes flow circuit back pressure and its impact on the system under test.

 
Features
  • 4 millisecond flow response
  • ¡¾2% of reading for high accuracy
  • High turndown ratio
  • Low pressure drop
  • Convenient analog output of flowrate
  • Versatile digital output of flowrate, volume, pressure, temperature
  • Built-in temperature and pressure compensation
 
RS232 Interface for digital outputs and configurable device options
  • Set analog output zero and scaling
  • Specify start/stop trigger levels for volume measurement
  • Set update rate for LCD display
  • Set sampling rate for analog and digital outputs
  • Select gas calibration
  • Select either standard or volumetric flow measurement
  • Set display units for Model 4140 to L/min or cm3/min
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TS33103   4040   High Accuracy Mass Flowmeter for High Flow   Yes   1,890,000
TS33104   4140   High Accuracy Mass Flowmeter for Low Flow   Yes   1,674,000
TS33105   1319201   OPTIONAL Carrying case for model: 4140 FOR High Accuracy Mass Flowmeters for Gases   Yes   140,400

 

TS33106   1319176   OPTIONAL Carrying case for model: 4040 FOR High Accuracy Mass Flowmeters for Gases   Yes   140,400