ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > ÀÚÀ̷νºÄÚÇÁ Gyroscope, MEMS ·Î°Å¿ë ½ë¼ ÀÚµ¿Â÷¿ë ¼¾¼ ÇöÀç ºÐ·ù > ¿Âµµ¹× ¿·ù ½ë¼ ½Àµµ ½ë¼ ½À±â ½ë¼ ³ëÁ¡ ½ë¼ dz¼Ó ½ë¼ ¾Ð·Â ½ë¼ Èû ½ë¼ º¯À§ ½ë¼ ¼Óµµ ½ë¼ À¯·® ½ë¼ Àü±â ½ë¼ ½Ç³»°øÁ¶ ½ë¼ ±â»ó°üÃø ½ë¼ ±¤º¹»ç ½ë¼ ¼öÁú ½ë¼ °¡½º ½ë¼ ¿ÂµµÁ¶Àý±â ½ë¼ Àû¿Ü¼± ½ë¼ ±³Á¤±â ½ë¼ ÇöÀç ºÐ·ù
ALMEMO¢ç 6290-7K Climate Printer and Data Logger
Climate printer or climate data logger for room monitoringwith mains or battery operation.
ALMEMO¢ç 6290-7K Climate Printer and
Data Logger with Ring Memory
Technical Features: ¡Ü
Climate printer or climate data logger for room monitoringwith
mains or battery operation.
¡Ü Various combinations
of measuring ranges can be set for temperature and humidity.
¡Ü One measuring
input, two measuring channels can be scanned.
¡Ü Two output
sockets for analog output, digital
interface, trigger input, alarm contacts.
¡Ü Easy-to-read
8-digit LCD double display.
¡Ü Key switch
for protection against unauthorised access.
¡Ü Data Recording:
2 diagrams side-by-side, optionally 2 lines in a diagram or list printout,
time, date, limit values, paper feed in mm or print cycle, start/stop of
measurement via keypad, 25-digit record headline, programmable via software
and data cable. Data cable allows for PC online measurements.
¡Ü Data Logger
Functions:
All cyclic acquired data will be stored and can be
subsequently provided, completely or in extracts, as output in different
formats. Plots with free selectable parameters, list and alarm value printout,
data transfer to PC are available.
The function ¢¥Daily Printout¢¥, triggered by the changing of the date, can
be selected instead of the cyclic printout.
Extent of the delivery
mA62907K
incl. mains adapter ZB6290NA 7.5V/450mA,
2 rolls temperature sensitive paper, operating instructions, ALMEMO¢ç
Manual including software AMR-Control Climate printer ALMEMO¢ç 6290-7K
mA62907KS
Climate data logger ALMEMO¢ç 6290-7KS
Technical Data:
Measuring inputs:
1 ALMEMO¢ç socket for
ALMEMO¢ç flat connector
Measuring channels:
2 channels (temp./humidity)
Measuring ranges:
temp. -20.00 ¡¦ 80.00¡ÆC
humid. 0.0 ¡¦ 100.0%H
Sensor power supply:
approx. 9V unregulated,
max. 80mA
Equipment:
Display:
61/2 digits, 7-segment,
2 digits, 16-segment, 12mm
Keypad:
7 keys with key switch
Memory (type S):
512kB (100000 values)
buffered with lithium battery
Time and date:
real time clock
buffered with lithium battery
Built-In Printer:
thermal, dot matrix (7x5)
Character size:
2.4 x 1.1mm
Number of columns:
40 characters/line
Print speed:
0.6 lines/s
Paper:
Jujo Paper Co. TP50K5-A
80mm wide, ¨ª 40
Outputs:
2 ALMEMO¢ç sockets
Power supply:
4 NiCd batteries, 4.8V, 0.8Ah
with quick charge circuitry
Mains adapter:
ZB 6290-NA 7.5 V, 450mA,
charging time: approx. 3h
Current consumption:
OFF: approx. 0.04mA
ON without print: appr. 11mA
ON with print: approx. 500mA
Operating time normal:
in
sleep mode:
90 hrs without print
alphanumerical: 5000 cycles
graphical: 15000 cycles
Power supply control:
automatic with visual alarm
Housing:
H180 x W115 x T70mm
ABS high impact strength
Accessories:
ZB1040TP10
Temperature-sensitive paper 10 rolls
ZB6290UK
DC voltage adapter cable
10 to 30VDC, 12V/250mA electr. isol.
ZA1601RK
ALMEMO¢ç recording cable
-1.25 to 2.00V
ZA1909DK5
ALMEMO¢ç data cable
V24 interface, electr. isol.
ZA1999NK5
ALMEMO¢ç network cable
current-loop, electr. isol.
ZA1000EGK
ALMEMO¢ç input/output cable
for triggering, limit value alarm
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.