ÇöÀçÀ§Ä¡ : Home > ÀÌ¿Â ÃøÁ¤±â ¹æ»ç¼±ÃøÁ¤±â UV PROCESS µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è Àü±â ¹× Àü·ÂÃøÁ¤±â ±â»ó°üÃø±â ÃÊÁß°í°úÇб³À°Àåºñ ¾Ð·Â°è ¿È»óÄ«¸Þ¶ó ¿Â¶óÀεβ²ÃøÁ¤±â °æµµ°è Àû¿Ü¼±¿Âµµ°è,¿Âµµ°è ¼ÒÀ½Áøµ¿°è ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â ³ëÁ¡,¿Â½Àµµ,¼öºÐ°è UV°ü·ÃÁ¦Ç° ȸÀü¼öÃøÁ¤±â Lutron1 Á¦Ç° (Àü±â, ÀüÀÚ °èÃø±â) ÀÎÀå¾ÐÃà ÅÙ¼Ç,ÅäÅ© ½ÃÇè±â ÃÊÀ½Æĵβ² ÃøÁ¤±â, Ž»ó±â ÄÚÆõµ±Ý µÎ²²ÃøÁ¤±â dz¼Ódz·®°è À¯·®°è ¿·ù°è, ¿·®°è ±¼Àý°è, Æí±¤°è ÀüÀÚÀú¿ï °¡½ºÃøÁ¤±â ºÐÁø ÀÔÀÚ¼ö ÃøÁ¤±â ¸éÀúÇ× ÃøÁ¤±â »öÂ÷°è, ±¤Åðè Ư¼öÄ«¸Þ¶ó(°í¼Ó °íÇØ»ó) ºÐ±¤±¤µµ°è (Spectrophotometer) ·¹ÀÌÀú Ç¥¸éÁ¶µµ°è Á¤Àü±â, ÀüÀÚÆÄ ÃøÁ¤±â ¿¬¼ÒÈ¿À²ÃøÁ¤±â ¼öÁú½ÃÇè±â ¹°¸®·® ¹°¼º ÃøÁ¤±â ½ë¼ ·¹º§°è (Level) Àü±â°èÃø±â, ÀüÀÚ°èÃø±â Lutron2 Á¦Ç° (¼öÁú,ȸÀü¼ö,¼ÒÀ½Áøµ¿, ±¤·®, ¿Â½Àµµ, dz¼Ó) Testo (¿Âµµ, ½Àµµ, dz¼Ó, ¾Ð·Â, ¼ÒÀ½, RPM, °¡½º) °ø±¸°èÃø±â(Mitutoyo) DAVIS (»óÇ° 25000°³) ºñÆı« ½ÃÇè±â Gardner DNA Fluke Á¦Ç° ¿Âµµ°è Thermometer ºñµð¿À °Ë»ç Çö¹Ì°æ ÀÌÈÇбâ±â ³ó¾÷¿ë ½ÃÇè±â ±¹»ê Á¦ÀÛ±â±â ¹ßÀü±â, ¹èÅ͸® ¹× ÃæÀü±â ÀÇ·á¿ë °èÃø±â ¼Ö¶ó¼¿ (žçÀüÁö), dz·Â, ¼Ò¼ö·Â, ¿¬·áÀüÁö X-Ray °ø±¸°èÃø±â (Fowler) ¿ëÁ¢±â ¹ÝµµÃ¼ Àåºñ À¯¸® ÃøÁ¤±â CRM (°í°´°ü¸®¿ë) ¼ÒÇÁÆ®¿þ¾î ESCO (¿¡½ºÄÚ) µî·Ï Àåºñ ¹«¼±ÃøÁ¤±â ½ÅÁ¾Ç÷ç Àåºñ µ¥ÀÌÅͼöÁý½Ã½ºÅÛ (Data Acquisition) optris(¿ÉÆ®¸®½º) ¹ýÁ¤½ÃÇèÀåºñ (µî·ÏÇã°¡ Àåºñ) ÁÖ¹®»óÇ° Ưº°»óÇ° LED ·¥ÇÁ ¹èÅ͸® 3D Printer Àå±âÀç°í ƯÆÇ (2020³â2¿ù) HOTIK (XINTEST) Á¦Ç° RIGOL Á¦Ç° (Å×½ºÆ®½Ã½ºÅÛ) KEM Á¦Ç° (ºÐ¼®Àåºñ) Ư°¡ÆǸŻóÇ° ±â·ùÃøÁ¤±â ¹× dzµ¿½ÇÇèÀåÄ¡ Ç¥¸é¿°ºÐÃøÁ¤±â ³²ÀÚÀÇ ¹°°Ç(RC) ¿È»óÄ«¸Þ¶ó (Áø´Ü¿ë) MYWATT ½º¸¶Æ® Àü·Â ÃøÁ¤·Î°Å TESTO Àå±âÀç°í (ƯÆÇ) TES Àå±âÀç°í (ƯÆÇ) ÇöÀç ºÐ·ù > Electronic ÀüÀÚ°èÃø±â Àü±â°èÃø±â Electrical À½¼º µ¥ÀÌÅÍ Voice/Data °øÁ¤Á¦¾î process & Control ±³Á¤±â Calibrators µ¥ÀÌÅͷΰÅ, ±â·Ï°è Datalogger, Recorder ¿Âµµ Temperature ½Àµµ/³ëÁ¡/¼öºÐ Humidity/Dewpoint/Moisture General Test Scales ÀüÀÚ Àú¿ï Data Acquisition/Recorders µ¥ÀÌÅÍ ¼öÁý ¹× ±â·Ï°è Panel Meters Safety ¾ÈÀü¿ë Á¦Ç° Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â Flow À¯·®°è Pressure ¾Ð·Â°è, Áø°ø°è Water Quality ¼öÁú ½ÃÇè±â Level Speed ȸÀü¼ö ÃøÁ¤±â Physical Dimension °ø±¸ ¹× ¹°¸® ½ÃÇè±â Vibration Leak Detection ´©¼³ ŽÁö±â Weather ±â»ó °üÃø±â Light Á¶µµ ÃøÁ¤±â Sound Shipping Cases Ahlborn Á¦Ç° ÇöÀç ºÐ·ù > ¿À½Ç·Î½ºÄÚÇÁ Oscilloscope ¸ÖƼ¸ÞÅÍ Multimeter ÁÖÆļöÄ«¿îÅÍ Frequency Counter ÆÄÇü¹ß»ý±â Waveform Generator LCR Meter Capacitance Meter ÀúÇ׹߻ý±â Resistance Box Ç¥ÁØ Capacitor Àü¿ø°ø±Þ±â Power Supply ¼Áö Â÷´Ü±â Surge Suppressor ÇöÀç ºÐ·ù
EH410 Manual Raniging DMM
Features
Models EH450 and EH470 include built-in non-contact IR thermometer with laser!
Low current capability – measure down to 0.1µA
Audible and visual input alerts
Easy to read 1 inch digits on backlit display
MAX (Model EH450) and RELATIVE (Models EH430 and EH470) functions
IR thermometer has 8:1 distance to target ratio, 0.95 fixed emissivity
Complete with CAT III test leads, multi-position tilt stand and velcro strip for hanging, protective holster with test lead holder, bead wire temperature probe (except Model EH450) and 9V battery
Advantages of Non-Contact InfraRed Temperature with laser
Troubleshoot - Quickly locate hot spots
Distance - 8:1 distance to target ratio allows for measurements in areas that are normally difficult or unsafe to reach
Speed - Point and shoot with final result in seconds
Convenience - No cables or probes to connect, break or lose
SPECIFICATIONS
Models
EH410
EH411
EH430
EH450
EH470
Description
Manual Ranging
DMM
True RMS
DMM
True RMS
Autoranging DMM
DMM +
IR Thermometer
True RMS DMM +
IR Thermometer
Backlit Display
2000 Counts
4000 Counts
2000 Counts
4000 Counts
4000 Counts
Basic Accuracy
¡¾0.5% (VDC)
¡¾0.3% (VDC)
¡¾0.5% (VDC)
¡¾0.3% (VDC)
¡¾0.3% (VDC)
DC Voltage
0.1mV to 600V
0.1mV to 600V
0.1mV to 600V
0.1mV to 600V
0.1mV to 600V
AC Voltage
1mV to 600V
1mV to 600V
0.1mV to 600V
0.1mV to 600V
0.1mV to 600V
DC Current
0.1¥ìA to 20A
0.1¥ìA to 20A
0.1¥ìA to 20A
0.1¥ìA to 20A
0.1¥ìA to 20A
AC Current
0.1mA to 20A
0.1mA to 20A
0.1¥ìA to 20A
0.1¥ìA to 20A
0.1¥ìA to 20A
Resistance
0.1¥Ø to 20M¥Ø
0.1¥Ø to 20M¥Ø
0.1¥Ø to 40M¥Ø
0.1¥Ø to 20M¥Ø
0.1¥Ø to 40M¥Ø
Capacitance
—
—
0.01nF to 100¥ìF
—
0.01nF to 100¥ìF
Frequency
—
—
0.001Hz to 10MHz
—
0.001Hz to 10MHz
Temperature
-4 to 1382¡ÆF
-4 to 1382¡ÆF
-4 to 1382¡ÆF
—
-4 to 1382¡ÆF
(Type K)
(-20 to 750¡ÆC)
(-20 to 750¡ÆC)
(-20 to 750¡ÆC)
(-20 to 750¡ÆC)
Temperature
—
—
—
-4 to 518¡ÆF
-4 to 518¡ÆF
(InfraRed)
(-20 to 270¡ÆC)
(-20 to 270¡ÆC)
Diode/Continuity
Yes
Yes
Yes
Yes
Yes
CAT Rating
CAT III-600V
CAT III-600V
CAT III-600V
CAT III-600V
CAT III-600V
Catalog No.
Description
Price
EH410
Manual Ranging DMM
89,964
EH411
True RMS Manual Ranging DMM
126,684
EH430
True RMS Autoranging DMM
163,404
EH450
Autoranging DMM+IR Thermometer
200,124
EH470
True RMS DMM+IR Thermometer
211,140
EH1194143
Vinyl Pouch Carrying Case
34,884
»ç¿ëÈı⠸®½ºÆ®
Á¦¸ñ
Æò°¡
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ. Æò°¡Çϱâ
»óÇ°¹®ÀÇ ¸®½ºÆ®
Á¦¸ñ
´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
¹®ÀÇÇϱâ
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.