AM87120 Dry Block Calibrator

Á¦Á¶»ç : DAVIS
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Easy Temperature Calibrator
The Easy Temperature Calibrators are possibly the fastest dry-block calibrators available today. These units are characterized by their portability and ease of use. The series are available in both heating and cooling configurations. Calibrators are supplied with a multi-hole block to meet virtually any industrial application. These units heat-up and cool down quickly to allow for rapid turn around of calibration and testing requirements.
Features
  • Automated Switch Testing
  • Programmable Slope Rates
  • Programmable Minimum/Maximum
  • Lightweight, Portable, and Easy-To-Use
  • Short Heating and Cooling Times
  • Mains Variance Immunity
  • Multiple block configurations
  • Standard RS232
SPECIFICATIONS
AM87120/AM87121

AM87122/AM87123/AM87124

Temperature Range Min. @73¡ÆF/23¡ÆC

14¡ÆF (-10¡ÆC)

82¡ÆF (28¡ÆC)

Maximum

257¡ÆF (125¡ÆC)

752¡ÆF (400¡ÆC)

Accuracy

¡¾0.9¡ÆF (¡¾0.5¡ÆC)

¡¾0.9¡ÆF (¡¾0.5¡ÆC

Stability

¡¾0.09¡ÆF (¡¾0.05¡ÆC)

¡¾0.27¡ÆF (ñ0.15¡ÆC)

Resolution (selectable)

1¡Æ or 0.1¡ÆF/C

Heating Time (ambient to max)

18 minutes

9 minutes

Cooling Time (max to 112¡ÆF/50¡ÆC)

21 minutes

Cooling Time (max to 212¡ÆF/100¡ÆC to 32¡ÆF/0¡ÆC)

18 minutes

N/A

Time to Stability

10 minutes - with Visual and Audible Indication

Programmable Slope Rates

0.1 - 9.9¡ÆF/C

Automatic Step

Up to 9 Steps with Programmable Dwell Time

Communications

RS232

Software

AMECAL-Light Software

Line Voltage Multivoltage - 115 (90-132) VAC 45-65 Hz and 230 (180-264) VAC 45-65 Hz
115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User Changeable
Insertion Block ETC125A Type 01 - 4 mm, 6 mm, 8 mm, 12.5 mm
ETC125A Type 02 - 5/32 in, 1/4 in, 3/8 in, 1/2 in
ETC400A Type 11 - 1/16 in, 5/32 in, 1/8 in, 1/4 in, 3/16 in
ETC400A Type 12 - 1/16 in, 1/8 in, 1/4 in, 3/16 in, 3/8 in
ETC400A Type 21 - 2 mm, 3 mm, (2) 4 mm, 6 mm
Immersion Depth (including insulation on ETC125A)

4.3 in / 70 mm

4.1 in / 105 mm

Weight

3.9 lbs / 1.8 kg

3.5 lbs / 1.6 kg

Dimensions (L x H x W)

13.6 x 9.3 x 5.3 in (350 x 235 x 135 mm)

Operating Temperature

32 - 104¡ÆF (0 - 40¡ÆC)

Humidity

0 - 90% RH

Protection Class

IP-10

EMC

EN61326-1:2001 EN61010-1:2001

Certification NIST Traceable Certification with Data Points
Standard delivery AM87120/AM87121 Calibrator, AMECAL-LIGHT software, RS232 cable, Manual, Power Cable, Shoulder Strap, Leads, Insertion Tube, Tool
AM87122/AM87123/AM87124 Calibrator, AMECAL-LIGHT software, RS232 cable, Manual, Power Cable, Shoulder Strap, Leads

CAT NO. MODEL DEscRIPTION AVAIL PRICE
AM87120 ETC125A115BO1E Dry Block Calibrator, Type 01 Insertion Block Yes 3,662,820
AM87121 ETC125A115B02E Dry Block Calibrator, Type 02 Insertion Block Yes 3,662,820
AM87122 ETC400A115B11E Dry Block Calibrator, Type 11 Insertion Block Yes 2,377,620
AM87123 ETC400A115B12E Dry Block Calibrator, Type 12 Insertion Block Yes 2,377,620
AM87124 ETC400A115B21E Dry Block Calibrator, Type 21 insertion Block Yes 2,377,620
AM87125 124094 OPTIONAL Carrying case for Calibrators FOR Easy Series Dry Block Calibrators Yes 284,580