Industrial Temperature Calibrator The Industrial Temperature Calibrators are easy to use and offer accuracies seen in laboratory units. The calibrators are portable and offer the user the benefit of dual-zone heating well control offsetting the effects of shorter probes or probes with large heads. This series is available in 3 ranges and deep wells are not necessary due to the advanced well controls. The series is programmable and can be used as a stand-alone calibrator to perform complete routines.
Features
Dual-zone heating control (AM81126 and AM81127)
Improved Block Design and Accuracy
Automated Features
Programmable Minimum/Maximum
Lightweight, Portable, and Easy-To-Use
Short Heating and Cooling Times
Mains Variance Immunity
Multiple Hole Insertion Tube Standard
Standard RS232
SPECIFICATIONS
¡¡
AM81125
AM81126
AM81127
Temperature Range
Min. @73¡ÆF/23¡ÆC
-19¡ÆF (-23¡ÆC)
91¡ÆF (33¡ÆC)
91¡ÆF (33¡ÆC)
Maximum
311¡ÆF (155¡ÆC)
608¡ÆF (320¡ÆC)
1202¡ÆF (650¡ÆC)
Accuracy
¡¾0.45¡ÆF (¡¾0.25¡ÆC)
¡¾0.54¡ÆF (¡¾0.3¡ÆC)
¡¾0.9¡ÆF (¡¾0.5¡ÆC)
Stability
¡¾0.05¡ÆF (¡¾0.03¡ÆC)
¡¾0.05¡ÆF (¡¾0.03¡ÆC)
¡¾0.07¡ÆF (¡¾0.04¡ÆC)
Resolution (selectable)
1¡Æ or 0.1¡ÆF/C
Heating Time (ambient to max)
14 minutes
7 minutes
25 minutes
Note
Including insertion tube
Cooling Time (max to 212¡ÆF/100¡ÆC)
4 minutes
30 minutes
56 minutes
Cooling Time (max to 212¡ÆF/100¡ÆC to 32¡ÆF/0¡ÆC)
10 minutes
N/A
N/A
Time to Stability
10 minutes - with Visual and Audible Indication
Programmable Slope Rates
0.1 - 9.9¡ÆF/C
Automatic Step
Up to 9 Steps with Programmable Dwell Time
Communications
RS232 Standard
Software
AmeCal-Temperature Software (Included)
Line Voltage
140/320
115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User Changeable
650
115 (90-127) VAC 45-65 Hz or 230 (180-254) VAC 45-65 Hz, User Changeable
Insertion Tube
Multi-Hole Standard (Other Sizes Available)
Immersion Depth (including insulation on AM81125)
6.3 in / 160 mm
5.9 in / 150 mm
5.9 in / 150 mm
Well Diameter
0.79 in / 20 mm
1.18 in / 30 mm
1.18 in / 30 mm
Weight
16.8 lbs / 7.6 kg
14.3 lbs / 6.5 kg
18.7 lbs / 8.5 kg
Dimensions (L x H x W)
9.5 x 5.5 x 14.8 in (241 x 139 x 375 mm)
Operating Temperature
32 - 104¡ÆF (0 - 40¡ÆC)
Humidity
0 - 90% RH
Protection Class
IP-10
EMC
EN61326-1:1997/A1:1998 EN61010-1:1993/A2:1995
Certification
NIST Traceable Certification with Data Points
Standard delivery
AM81125
Calibrator, AMECAL software, RS232 cable, Manual, Power Cable, Leads, Insertion Tube, Tool, Insulation Cap
Most insertion tubes include a 4 mm hole for reference probes. Additional insertion tubes avaliable in increments from 1/8-7/8 in, 3-20 mm, and Imperial or Metric Multi-Hole sizes. Please Inquire.
AM81126
ITC320A115BM06G
Dry Block Calibrator, 115V w/ Multi-Hole Insert
Yes
7,299,936
Most insertion tubes include a 4mm hole for reference probes. Additional insertion tubes avaliable in increments from 1/8 - 7/8 in, 3-20 mm and Imperial or Metric Multi-Hole sizes. Please Inquire.
AM81127
ITC650A115BM06G
Dry Block Calibrator, 115V with Multi-Hole Insert
Yes
97,791,984
Most insertion tubes include a 4mm hole for reference probes. Additional insetion tubes avaliable in increments from 1/8 - 7/8 in, 3 - 20 mm, and Imperial or Metric Multi-Hole sizes. Please Inquire.
AM81128
OPTC-C
OPTIONAL Carrying Case for Calibrators FOR Industrial Series Dry Block Calibrators