HR9140A Dry-Well Calibrator

Á¦Á¶»ç : DAVIS
½ÃÁß°¡°Ý : ¿ø
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

These new units beat every other comparable dry-well in the industry in performance, size, weight, convenience, ease of calibration, software and price. In addition, the heating and cooling rate of each of these dry-wells is adjustable from the front panel, thermal switches can be checked by these units for actuation testing and multiple-hole inserts are available for a variety of probe sizes.

¡¡

Choose one of three removeable inserts sized from 1/16" to 1/2" diameter. Insert A handles a full range of probe sizes with a single well of each size. Insert B features two wells each of 3/8", 1/4" and 3/16" in diameter for doing comparison calibrations, and insert C has six 1/4" diameter wells for multiple probe calibrations
 
Features
  • Accuracy to ¡¾0.5¡ÆC
  • RS-232 and Windows¢ç software included
  • Easy to recalibrate
  • Less than eight pounds
 
SPECIFICATIONS — Series ZB

Range

-25 to 140¡ÆC (-13 to 284¡ÆF), in ambient of 23¡ÆC
¡¾3¡ÆC (Can do lower depending on ambient.)
Accuracy ¡¾0.25¡ÆC
Stability ¡¾0.02¡ÆC @ -25¡ÆC, ¡¾0.04¡ÆC @ 140¡ÆC
Uniformity ¡¾0.3¡ÆC typical (¡¾0.1 with similar size wells)
Resolution 0.1¡Æ
Display Scale ¡ÆF or ¡ÆC, switchable
Heating Time 18 minutes, ambient to 140¡ÆC
Cooling Time 20 minutes, ambient to -25¡ÆC
Stabilization Time 7 minutes
Inserts (included) Insert A: 1/2", 3/8", 1/4", 3/16", 1/8" and 1/16" holes
Depth 4.875 inches (124 mm) immersion
Computer Interface RS-232 included
Size 10.25" H x 5.63" W x 9.63" D (26.1 x 14.3 x 24.5 cm)
Weight 12.5 lb. (5.7 kg)
Certification 7-point NIST-traceable certificate of calibration included

SPECIFICATIONS

Model

Series ZA (shown right) Series ZC (shown left)
Range 95¡ÆF to 662¡ÆF (35¡ÆC to 350¡ÆC) 122¡ÆF to 1202¡ÆF (50¡ÆC to 650¡ÆC)
Accuracy ¡¾0.9¡ÆF (¡¾0.5¡ÆC); accuracy in insert holes greater than 1/4" will be at ¡¾1.8¡ÆF (¡¾1¡ÆC)  122¡ÆF to 752¡ÆF (50¡ÆC to 400¡ÆC):
¡¾0.9¡ÆF (¡¾0.5¡ÆC), 752¡ÆF to 1202¡ÆF (400¡ÆC to 650¡ÆC):
¡¾1.8¡ÆF (¡¾1¡ÆC), holes greater than 1/4" (6.35 mm): ¡¾3.6¡ÆF (¡¾2¡ÆC)
Stability ¡¾0.03¡ÆC @ 50¡ÆC; ¡¾0.05¡ÆC @ 100¡ÆC; ¡¾0.10¡ÆC @ 500¡ÆC;
¡¾0.05¡ÆC @ 350¡ÆC ¡¾0.12¡ÆC @ 650¡ÆC
Uniformity ¡¾0.72¡ÆF (¡¾0.4¡ÆC) typical ¡¾0.18¡ÆF (¡¾0.1¡ÆC) with similarly sized wells 122¡ÆF to 752¡ÆF (50¡ÆC to 400¡ÆC): ¡¾0.72¡ÆF (¡¾0.4¡ÆC) typical, ¡¾0.9¡ÆF (¡¾0.5¡ÆC) with similarly sized wells above 752¡ÆF (400¡ÆC)
Heating Times 12 minutes from ambient to 662¡ÆF (350¡ÆC) 12 minutes from ambient to 1202¡ÆF (650¡ÆC)
Cooling Times 15 minutes from 662¡ÆF to 212¡ÆF (350¡ÆC to 100¡ÆC) 25 minutes from 1202¡ÆF to 212¡ÆF (650¡ÆC to 100¡ÆC)
Stabilization Time 7 minutes
Immersion Depth 4.875 inches (124 mm)
Computer Interface RS-232 included with free Windows¢ç-based software (Model 9930)
Power 115 VAC (¡¾10%), 50/60 Hz and 230 VAC (¡¾10%), 50/60 Hz switchable
Size 6" W x 3.375" H X 7.75" D (152 x 86 x 197 mm) 4.5" W x 9" H x 7" D (114 x 229 x 178 mm)
Weight 6 lb. (2.7 kg) 8 lb. (3.6 kg)
Certification Includes 7-point, NIST-traceable certificate of calibration with data at the following points: 50¡ÆC, 100¡ÆC, 150¡ÆC, 200¡ÆC, 250¡ÆC, 300¡ÆC and 350¡ÆC Includes 7-point, NIST-traceable certificate of calibration with data at the following points:100¡ÆC, 200¡ÆC, 300¡ÆC, 400¡ÆC, 500¡ÆC and 600¡ÆC

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
HR9140A   9140-A   9140 FIELD DRY WELL CALIBRATOR   Yes   4,525,740
HR9140B   9140-B   DRY-WELL (B INSERT INCLUDED)   Yes   4,525,740
HR9140C   9140-C   DRY-WELL (C INSERT INCLUDED)   Yes   4,525,740
HR9141A   9141-A   9141 FIELD DRY WELL CALIBRATOR   Yes   6,481,080
HR9141B   9141-B   DRY WELL (B INSERT INCLUDED)   Yes   6,481,080
HR9141C   9141-C   DRY WELL (C INSERT INCLUDED)   Yes   6,481,080
HR31401   3140-1   OPTIONAL INSERT BLANK FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   302,940

 

HR31402   3140-2   OPTIONAL INSERT A FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   348,840

 

HR31403   3140-3   OPTIONAL INSERT B FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   348,840

 

HR31404   3140-4   OPTIONAL INSERT C FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   348,840

 

HR9308   9308   OPTIONAL RUGGED CARRYING CASE FOR Field Temperature Dry-Well Calibrators   Yes   128,520

 

HR31411   3141-1   OPTIONAL INSERT-BLANK FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   459,000

 

HR31412   3141-2   OPTIONAL INSERT A FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   660,960

 

HR31413   3141-3   OPTIONAL INSERT B FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   660,960

 

HR31414   3141-4   OPTIONAL INSERT C FOR DRY WELL FOR Field Temperature Dry-Well Calibrators   Yes   660,960
HR9309   9309   OPTIONAL RUGGED CARRYING CASE FOR Field Temperature Dry-Well Calibrators   Yes   688,500