The durable robust temperature logger can stand up against virtually any environment. No wiring or cables required means that Nautilus85 can be easily introduced into any application.
The high temperature capabilities of the Nautilus 135 make it the ideal logger for extreme environments. It monitors high temperatures where conventional Dataloggers aren't able to survive.
SPECIFICATIONS — AR10261/AR10262
No. of Channels
One. (Ambient temperature)
Sensor type
Negative Temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25¡Æ (77¡ÆF)
Operating Range
-40 to 85¡ÆC (-40 to 185¡ÆF)
Resolution
0.4¡ÆC (0.7¡ÆF)
Sensor Accuracy
¡¾0.2¡ÆC (¡¾0.4¡ÆF) @25¡ÆC
Memory Size
32 KB
SPECIFICATIONS — AR10263/AR10264
No. of Channels
One. (Ambient temperature)
Sensor type
Negative Temperature Coefficient Thermistor (NTC) 10,000 ohms @ 25¡Æ (77¡ÆF)
Operating Range
10 to 135¡ÆC (-50 to 275¡ÆF)
Resolution
0.4¡ÆC (0.7¡ÆF)
Sensor Accuracy
¡¾0.5¡ÆC (0.9¡ÆF) @77¡ÆC
Memory Size
32 KB
CAT NO.
MODEL
DEscRIPTION
AVAIL
PRICE
AR10261
NTL-100 (01-0261)
Nautilus 85 Single Channel Temperature Datalogger with aluminum case
Yes
475,524
AR10262
NTL-101 (01-0262)
Nautilus 85 Single Channel Temperature Datalogger with stainless steel case
Yes
548,964
AR10263
NTL-102 (01-0263)
Nautilus 135 Single Channel Temperature Datalogger with aluminum case
Yes
659,124
AR10264
NTL-103 (01-0264)
Nautilus 135 Single Channel Temperature Datalogger with stainless steel case
Yes
732,564
AR10275
NTL-WIN (01-0275)
OPTIONAL Nautilus interface package with software & download cable FOR Thermistor Single Channel Temperature Dataloggers
Yes
236,844
AR10276
NTL-UPGRADE (01-0276)
OPTIONAL Nautilus Windows software upgrade for enhanced analysis FOR Thermistor Single Channel Temperature Dataloggers
Yes
71,604
AR340017
TR-EXPRESS-FULL
OPTIONAL TrendReader Express full install software is for new users of JR without any previous version of ACR software (CD format) FOR Thermistor Single Channel Temperature Dataloggers
Yes
145,044
AR340018
TR-EX-VALU-UPGRD
OPTIONAL TrendReader Express Value upgrade software FOR Thermistor Single Channel Temperature Dataloggers
Yes
108,324
For users of JR. Loggers who want to upgrade their old software versions with this new product (CD format).
AR340019
TR-EXPRESS-CONV
OPTIONAL TrendReader Express Conversion FOR Thermistor Single Channel Temperature Dataloggers
Yes
36,720
Required for PC owners with no CD drive (3.5" diskette format). This product needs to be purchased with the above products.
AR340023
TR-EX-MANUAL (34-0023)
OPTIONAL TrendRead express printed manual FOR Thermistor Single Channel Temperature Dataloggers