(ÁÖ)ÄÚ¸°½º

ºÐ·ù °Ë»ö

ÇöÀçÀ§Ä¡ : Home > > >

 
ÀÌÀü Å« À̹ÌÁö ´ÙÀ½

IP104 Four Channel high precision temperature

Á¦Á¶»ç : DAVIS
ÆǸŰ¡°Ý  : ¿ø
Æ÷ÀÎÆ® : Á¡
¼ö·® :
  PLUS   MINUS   °³
¡á ȸ¿ø°¡ÀÔÀ» ÇϽøé ÇÒÀεȰ¡°ÝÀ» º¸½Ç¼ö ÀÖ½À´Ï´Ù.
¡á ¸ðµç°¡°ÝÀººÎ°¡¼¼º°µµ ÀÔ´Ï´Ù.
¡á ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á 30¸¸¿ø¹Ì¸¸Àº Åùèºñ 3,000¿ø(ÂøºÒ)ÀÔ´Ï´Ù.
¡á Ä«µå°áÀç½Ã ¼¼±Ý°è»ê¼­ ¹ßÇà ºÒ°¡ÇÕ´Ï´Ù.
¡á ¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.

»ó¼¼ÆäÀÌÁö¸¦ ¸¶ÀÌÇÇÇ÷Πº¸³»±â - À¥¿ë »ó¼¼ÆäÀÌÁö¸¦ twitter·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ facebookÀ¸·Î º¸³»±â »ó¼¼ÆäÀÌÁö¸¦ Me2Day·Î º¸³»±â

Fiberoptic temperature sensors offer reliability and accuracy
LumiTherm¢â fiberoptic thermometers provide accu-rate and reliable measurements where others can't. The units can be used in high electromagnetic interference (EMI) environments, especially suitable for monitoring high voltage transformers and microwave processes. Fiber optic cladding makes the probes inert and safe to use in harsh chemical environments such as refineries, chemistry labs, mining operations, and pharmaceutical manufacturing. Probes are autoclaveable and instru-ment is self-calibrating. The LumiTherm¢â 500 is fully calibrated at the factory to NIST traceable standards. Calibration data for each probe is stored in individual Calibration Data Modules that are shipped with the probe. High stability, minimum drift.

Benefits
- High repeatability and accuracy of data - Expedites time spent from analysis to discovery of results - Saves time during processing and allows investigator to change conditions if needed - Flexibility in use of unit for many appli-cations - Ideal for microwave/RF or MRI envi-ronments - Probes can be reused saving future expenditures

 
Pharmaceutical & Biomedical
  • Real Time data logging & sample prep monitoring
  • Pharmacokinetic studies
  • Cardiac studies monitoring plaque inflammation
  • Map margins of metastasis of tumors
 
RF and Microwave Processing/ MRI
  • FMRI studies and cryogenic or laser prostate
  • Drying of pharmaceuticals and waste slurries
  • Curing of composites, resins and petroleum
  • Food processing, packaging and testing
  • Monitoring e-fields during processing
 
High Spark Hazard Processes
  • Operational maintenance of hydro-generators
  • Battery manufacturing and testing
  • Propellant extrusion and packaging
  • Chemical/Petroleum processing
  • Corrosive/electrochemical production control
  • Nuclear power plant monitoring
 
Electrical Power Generation
  • Hot spot monitoring in generators and transformers
  • Monitoring of winding temperatures
  • Diagnostic testing of high voltage components
 
SPECIFICATIONS — IP500

Range

-50 to 400 ¡ÆC (-58 to 752 ¡ÆF)
Accuracy ¡¾ 0.1 ¡ÆC
Repeatability ¡¾ 0.2 ¡ÆC
Precision Up to 0.01 ¡ÆC
NIST Traceable Absolute accuracy ¡¾ 1.0 ¡ÆC
Method Fluordecay

SPECIFICATIONS — IP104

Range

-20 to 80 ¡ÆC (-5 to 175 ¡ÆF)
Accuracy ¡¾0.1 ¡ÆC
Precision 0.01 ¡ÆC (FAST mode)
0.001 ¡ÆC (HI-RES mode)
NIST Traceable Absolute accuracy ¡¾1.0 ¡ÆC
Method Quartz Oscillator
Applications Calorimetry and phase change assays

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
IP104   ¡¡ ¡¡ LumiTherm¢â 104 (Optical)   Yes   10,534,050
Four Channel high precision temperature instrument. LED display, RS232 port, analog output, one fiber optic holder, V1 interface driver for LabView, user's manual and case Reads temperature -20-80¡ÆC, Programmable unit with alarms for max and min. temp. 
IP1044   ¡¡ ¡¡ LumiTherm¢â 104 (Electron)   Yes   11,016,000
Four Channel high precision temperature instrument. LED display, RS232 port, analog output, one fiber optic holder, V1 interface driver for LabView, user's manual and case, Reads temperature -20-80¡ÆC, Programmable unit with alarms for max and min. temp. 
IP1041   ¡¡ ¡¡ LT104 optical probe   Yes   826,200
IP1042   ¡¡ ¡¡ LT104 electronic probe   Yes   642,600
IP1043   ¡¡ ¡¡ FiberOptic Probe Holder   Yes   229,500