ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â > Combo Units

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
AFAV6 Air Velocity, Flow & Temperature Logger
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:AFAV6
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Air Velocity, Flow & Temperature Logger with 4" Diameter Vane Sensor.Ideal combination of air velocity
Features
  • Ideal combination of air velocity, volume flow and temperature
  • Fully featured - bar graph, min/max/avg. memory, multiple choice of display readings
  • Excellent accuracy with fast, effective processing power
  • Choice of 100mm and 35mm vane sensors
  • Four tools in one. Commissioning, testing, variable logging and diagnostic checks
  • Ideal for HVAC, process control, laboratory, safety, quality assurance, R & D engineers and indoor environment monitoring
  • Velocity, flow and temperature in metric or imperial display
  • Powerful processor for average/minimum/maximum with memory
  • Bar graph indicator
  • Analogue and RS-232 outputs
  • High clarity display with backlight
  • Auto shut off
  • Manual and automatic logging capability
  • Simply enter area or linear dimensions and read flow
  • RS-232 and Windows¢ç compatible
  • Perfect for both on-site checks and unattended monitoring
 
AV6 Measures
  • Air Velocity - m/sec, ft/min, mph, knots, km/h
  • Volume Flow - m3/sec, ft3/min (CMS, CFM)
  • Air Temperature - ¡ÆC, ¡ÆF
 
SPECIFICATIONS

Velocity Accuracy

¡¾1% of reading ¡¾1 digit
Velocity Resolution 0.01 m/Sec, 2 ft/min
Temperature Range 0-80¡ÆC, 32¡Æ to 176¡ÆF
Temperature Accuracy 1¡ÆC ¡¾ 1 Digit, 2¡ÆF ¡¾ 1 Digit
Temperature Resolution 0.1¡ÆC, 1¡ÆF
Area Input Range 0.004 - 99.99 m2, 0.0431 - 999.9 ft2
Linear Input Range 0.0001 - 9999 m, 1/8" - 9999 ft (subject to area limits)
Memory Size 99 readings of velocity and temperature (note flow data is stored as a velocity)
Auto Logging variable time base 5 seconds to 99 minutes 59 seconds
Analogue Output 0 - 1 volt (0-0.5v and 0-2v also available)
Digital Output RS232
Power Supply 4 x 1.5 volt AA cells. (rechargeable, zinc carbon or alkaline)
Battery Life 40 Hrs.
Overall Dimensions 92 x 32x 188 mm, 3.6 x 1.2 x 7.4 in.
Operating Environment Ambient operating temperature range = -10¡ÆC to +50¡ÆC
Instrument Storage temperature range = -20¡ÆC to +60¡ÆC
Operating Environment 0¡ÆC to 80¡ÆC (vane sensor)
Standard Kit AV6 Anemometer, 100 mm dia rotating vane sensor, Executive carry case, Calibration certificate, Handle & telescopic extension rod with swiveling joint (0.4 to 1.1M)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AFAV6   AV6   Air Velocity, Flow & Temperature Logger with 4" Diameter Vane Sensor   Yes   2,481,840

 

AFAV61   72343701   1.4" Diameter Vane Sensor with Temperature   Yes   861,840
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ