Air Velocity, Flow & Temperature Logger with 4" Diameter Vane Sensor.Ideal combination of air velocity |
Features |
- Ideal combination of air velocity, volume flow and temperature
- Fully featured - bar graph, min/max/avg. memory, multiple choice of display readings
- Excellent accuracy with fast, effective processing power
- Choice of 100mm and 35mm vane sensors
- Four tools in one. Commissioning, testing, variable logging and diagnostic checks
- Ideal for HVAC, process control, laboratory, safety, quality assurance, R & D engineers and indoor environment monitoring
- Velocity, flow and temperature in metric or imperial display
- Powerful processor for average/minimum/maximum with memory
- Bar graph indicator
- Analogue and RS-232 outputs
- High clarity display with backlight
- Auto shut off
- Manual and automatic logging capability
- Simply enter area or linear dimensions and read flow
- RS-232 and Windows¢ç compatible
- Perfect for both on-site checks and unattended monitoring
|
|
AV6 Measures |
- Air Velocity - m/sec, ft/min, mph, knots, km/h
- Volume Flow - m3/sec, ft3/min (CMS, CFM)
- Air Temperature - ¡ÆC, ¡ÆF
|
| | SPECIFICATIONS
Velocity Accuracy |
¡¾1% of reading ¡¾1 digit |
Velocity Resolution |
0.01 m/Sec, 2 ft/min |
Temperature Range |
0-80¡ÆC, 32¡Æ to 176¡ÆF |
Temperature Accuracy |
1¡ÆC ¡¾ 1 Digit, 2¡ÆF ¡¾ 1 Digit |
Temperature Resolution |
0.1¡ÆC, 1¡ÆF |
Area Input Range |
0.004 - 99.99 m2, 0.0431 - 999.9 ft2 |
Linear Input Range |
0.0001 - 9999 m, 1/8" - 9999 ft (subject to area limits) |
Memory Size |
99 readings of velocity and temperature (note flow data is stored as a velocity) |
Auto Logging variable time base |
5 seconds to 99 minutes 59 seconds |
Analogue Output |
0 - 1 volt (0-0.5v and 0-2v also available) |
Digital Output |
RS232 |
Power Supply |
4 x 1.5 volt AA cells. (rechargeable, zinc carbon or alkaline) |
Battery Life |
40 Hrs. |
Overall Dimensions |
92 x 32x 188 mm, 3.6 x 1.2 x 7.4 in. |
Operating Environment |
Ambient operating temperature range = -10¡ÆC to +50¡ÆC |
Instrument |
Storage temperature range = -20¡ÆC to +60¡ÆC |
Operating Environment |
0¡ÆC to 80¡ÆC (vane sensor) |
Standard Kit |
AV6 Anemometer, 100 mm dia rotating vane sensor, Executive carry case, Calibration certificate, Handle & telescopic extension rod with swiveling joint (0.4 to 1.1M) |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
AFAV6 |
|
AV6 |
|
Air Velocity, Flow & Temperature Logger with 4" Diameter Vane Sensor |
|
Yes |
|
2,481,840
|
AFAV61 |
|
72343701 |
|
1.4" Diameter Vane Sensor with Temperature |
|
Yes |
|
861,840 |
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|