KA7250 Air Velocity Meter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:KA7250
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The anemomaster performs simultaneous measurement of air velocity and temperature in high
The anemomaster performs simultaneous measurement of air velocity and temperature in high and middle temperature ranges. The probe KA7252 is for the temperature range from 0¡ÆC (32¡ÆF) to 500¡ÆC (932¡ÆF) and the probe KA7251 for 0¡ÆC (32¡ÆF) to 200¡ÆC (392¡ÆF). Accuracy for air velocity is ensured by the advanced temperature compensation system.
 
Features
  • Probe compatibility to allow use of the designated probe for each temperature range.
  • Accuracy ensured by the temperature compensation mechanism using platinum.
  • RS-232C terminal for Datalogging, analog output terminal, and a remote terminal.
  • 2-way power supply: dry cell battery or AC power.
  • Automatic calculation functions including averaging and flow rate.
 
SPECIFICATIONS
Ranges Velocity 0.2 – 50.0 m/s (40 – 9,840 fpm) for 0 – 99¡ÆC (32 – 211¡ÆF)
  0.4 – 50.0 m/s (80 – 9,840 fpm) for 100 – 199¡ÆC (212 – 391¡ÆF)
  0.7 – 50.0 m/s (138 – 9,840 fpm) for 200 – 299¡ÆC (392 – 571¡ÆF)
  1.0 – 50.0 m/s (197 – 9,840 fpm) for 300 – 400¡ÆC (572 – 720¡ÆF)
Temperature 0 –500¡ÆCF (32 – 932¡Æ)
Resolution Velocity 0.01 m/s for 0 to 9.99 m/s, 0.1 m/s for 10 to 50 m/s
Air Temperature 0.2¡ÆC (1¡ÆF) for 0 – 99¡ÆC (32 – 211¡ÆF)
  1¡ÆC (2¡ÆF) for 100 – 500¡ÆC (212 – 932¡ÆF)
Accuracy Velocity V0 to 4.99 m/s ¡¾0.15 m/s
  5.00 to 9.99 m/s ¡¾0.30 m/s
  10.0 to 24.9 m/s ¡¾0.75 m/s
  25.0 to 50.0 m/s ¡¾1.5 m/s
Temperature ¡¾(1% of reading +1¡ÆCF (2¡Æ))
Power/Battery Life 6 x 1.5 AA cells provide approx. 8 hours use
Dimensions 8.66" x 3.35" x 5.91" (220 x 85 x 150 mm)
Weight 0.88 lbs. (400g)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
KA7250   6162   Air Velocity Meter (probes sold separately)   Yes   4,309,200 
KA7251   0203   OPTIONAL High Temperature Velocity/Temperature Probe, range 32 to 392¡ÆF FOR High Temperature Air Velocity Meter   Yes   2,581,200

 

KA7252   0204   OPTIONAL Ultra High Temperature Velocity/Temperature Probe, range 32 to 392¡ÆF FOR High Temperature Air Velocity Meter   Yes   4,309,200

 

KA7700   6162-03   OPTIONAL Extension Rod for KA7251 FOR High Temperature Air Velocity Meter   Yes   429,840

 

KA7254   6162-04   OPTIONAL Extension Rod for KA7252 FOR High Temperature Air Velocity Meter   Yes   756,000

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ