ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Air Velocity / Manometer dz¼Ó ¹× ´ë±â¾Ð ÃøÁ¤±â > Miscellaneous

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
MS01120 -0.1-0.1" w.c. 120 VAC
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:MS01120
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Resolution: to .001 inches of water.Dependable solid state design.Rugged NEMA 13 enclosure
Features
  • Resolution: to .001 inches of water
  • Dependable solid state design
  • Rugged NEMA 13 enclosure
 
SPECIFICATIONS

Accuracy of reading

¡¾1% F.S.
Accuracy of alarm output ¡¾1% of setpoint (lights and relay)
Standard range ¡¾0.1 inches of water (or ¡¾ 25 Pascals)
Resolution 0.001" of water (or 0.1 Pascals)
Panel indicator lights one red & one green LED
Display LCD 3 digits 0.5" digit height
Alarm output SPDT relay contacts rated at 5A at 30 VDC or 120 VAC 4A at 240 VAC resistive
Deadband preset at 5% of range, field adjustable from 1 to 20%
Analog outputs 0-5VDC, 2.5V at zero pressure 2 mA max, 0-10VDC, 5V at zero pressure 2 mA max
4-20 mA sourcing, 12 mA at zero pressure, max loop resistance is 580 ohms
Power requirements 95-135/190-270 VAC 50/60 Hz or 19.5 to 30 VAC 50/60 Hz
Max power consumption 5 Watts
Operating medium air or non-corrosive non-explosive gas
Maximum momentary pressure limit ¡¾6.0 inches of water (¡¾1.5 kPa)
Operating Temperature 0¡ÆC to 50¡ÆC (32¡ÆF to 120¡ÆF)
Storage Temperature -30¡ÆC to 70¡ÆC (-20¡ÆF to 160¡ÆF)
Effect of temperature on reading ¡¾0.05%/¡ÆC
Operating humidity range 10% to 90% R.H.
Construction glass filled polycarbonate flammability rating of UL94 V-1
Cover clear polycarbonate flammability rating of UL94 V2
Knockouts 6 in lower front & 5 in back of enclosure
Hinges strong & removable allow hinging from either side open 180¡Æ
Mounting 3-point mounting
Weight 2.56 lb (1160g)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
MS01120   RMP-1-A-01E   ROOM PRESSURE MONITOR -0.1-0.1" w.c., 120 VAC   Yes   1,501,200 
MS04120   RMP-1-A-04E   ROOM PRESSURE MONITOR -0.5-0.5" w.c., 120 VAC   Yes   1,501,200 
MS05120   RMP-1-A-05E   ROOM PRESSURE MONITOR -1.0-1.0" w.c., 120 VAC   Yes   1,501,200 
MS01240   RMP-1-B-01E   ROOM PRESSURE MONITOR -0.1-0.1" w.c., 240 VAC   Yes   1,501,200 
MS04240   RMP-1-B-04E   ROOM PRESSURE MONITOR -0.5-0.5" w.c., 240 VAC   Yes   1,501,200 
MS05240   RMP-1-B-05E   ROOM PRESSURE MONITOR -1.0-1.0" w.c., 240 VAC   Yes   1,501,200 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ