Leak detection in either leak rate or pressure decay modes.Programmable damping.
Features
  • Leak detection in either leak rate or pressure decay modes
  • Flow velocity and volume measurement using standard pitot tubes and anubars
  • Automatic % error calculation simplifies transmitter or transducer calibration
  • Measurement of pressure, temperature, voltage and current
  • Two channel — simultaneous measurement and display of pressure, temperature, voltage or current in any combination
  • Interchangeable pressure and temperature modules
  • Programmable damping
 
SPECIFICATIONS

Standard Display

Alphanumeric LCD, 0.37-inch height, 2 lines, 16 characters/line
Engineering Units psi, in.H2O, in. Hg, ftSW, bar, mbar, kPa, Mpa, mmHg, cmH2O, mmH2O and kgcm2 and any single user-programmable engineering unit
Temperature Range 32¡Æ to 120¡ÆF (0 to 49¡ÆC)
Electrical Sourcing Specification 24 Vdc at 25 mA
Electrical Measurement Specification
Inputs (Volts) Accuracy
0/10 Vdc ¡¾0.025% F.S.
0/30 Vdc ¡¾0.10% F.S.
Input (mA) Accuracy
0/20 mA ¡¾0.03% F.S.
0/50 mA ¡¾0.05% F.S.
RS232 Serial Interface with 9-pin D type at 300, 1200, 2400, 9600 baud
Weight ST-2A Base unit: 3.0 lb (1.4 kg)

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AS21   ST2A1   Two Line Digital Display Unit with 70 VAC/60 Hz AC Adapter   Yes   2,581,200 
AS22   ST2A2   Two Line Digital Display Unit with 230 VAC/50 Hz AC Adapter   Yes   2,581,200 
AS23   ST2A3   Two Line Digital Display Unit with 100 VAC/50 Hz AC Adapter   Yes   2,581,200 
AS300   B   OPTIONAL Back Lit LCD Display FOR Digital Pressure/Leak Indicator   Yes   205,200 
AS3021   N   OPTIONAL NiCad Batteries (rechargeable) FOR Digital Pressure/Leak Indicator   Yes   205,200

 

AS303   A   OPTIONAL Alkaline Batteries (non-rechargeable) FOR Digital Pressure/Leak Indicator   Yes   205,200

 

AS304   H   OPTIONAL Handle FOR Digital Pressure/Leak Indicator   Yes   86,400 
AS305   L   OPTIONAL Loop Power Supply FOR Digital Pressure/Leak Indicator   Yes   492,480 
AS306   P   OPTIONAL Panel Mounting Brackets FOR Digital Pressure/Leak Indicator   Yes   54,000 
AS308   D1   OPTIONAL Standard Data Logging Memory & High/Low Alarms and Differential Measurement Firmware FOR Digital Pressure/Leak Indicator   Yes   475,200

 

AS322   AQS-TC1   OPTIONAL TC Interface for J, K, T FOR Digital Pressure/Leak Indicator   Yes   896,400 
AS310   PPT-RT1   OPTIONAL RTD PROBE FOR Pt100, Ni 120, Cu 10 FOR Digital Pressure/Leak Indicator   Yes   982,800

 

AS311   AQS-RT2   OPTIONAL RTD interface assembly for use with Pt1000 RTD probe and other RTDs with resistance outputs of 4000 ohms or less FOR Digital Pressure/Leak Indicator   Yes   896,400

 

AS312   840X010-01   OPTIONAL Pt100 (385), 0.125 diameter, 12 inch length, handle and 5 ft. coiled cable FOR Digital Pressure/Leak Indicator   Yes   645,840

 

AS313   840X010-02   OPTIONAL Pt100 (385), 0.25 diameter, 12 inch length, handle and 5 ft. coiled cable FOR Digital Pressure/Leak Indicator   Yes   645,840

 

AS314   840X010-02   OPTIONAL Pt100 (385), 0.125 diameter, 6 inch length, handle and 5 ft. coiled cable FOR Digital Pressure/Leak Indicator   Yes   645,840

 

AS315   840X010-06   OPTIONAL RTD PROBE-6" LGTH, HANDLE, 5' CABALE (0.25) FOR Digital Pressure/Leak Indicator   Yes   637,200

 

AS316   840X010-03   OPTIONAL Pt100 (385), 0.125 diameter, 12 inch length, 10 ft. standard cable FOR Digital Pressure/Leak Indicator   Yes   594,000

 

AS317   840X010-04   OPTIONAL Pt100 (385), 0.25 diameter, 12 inch length, 10 ft. standard cable FOR Digital Pressure/Leak Indicator   Yes   594,000

 

AS318   840X010-07   OPTIONAL Pt100 (385), 0.125 diameter, 6 inch length, 10 ft. standard cable FOR Digital Pressure/Leak Indicator   Yes   594,000

 

AS319   840X010-08   OPTIONAL Pt100 (385), 0.25 diameter, 6 inch length, 10 ft. standard cable FOR Digital Pressure/Leak Indicator   Yes   594,000

 

AS320   828X136-01   OPTIONAL TA4F mating connector for use with AQS-RT module and our own RTD probes. (probes are supplied with the TA4F connector) FOR Digital Pressure/Leak Indicator   Yes   43,200

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ