ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¾Ð·Â Pressure

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ML200101 Dual range pressure calibrator
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:ML200101
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Dual isolated 316SS pressure sensors with a rugged nickel plated manifold designed
Features
  • Dual isolated 316SS pressure sensors with a rugged nickel plated manifold designed for harsh environments
  • Robust design - A NEMA 4X water resistant sealed case and a sealed membrane keypad suited for the most rigorous applications
  • Versatile broad pressure ranges individually temperature compensated for high accuracy over a broad operating range of 0-50¡ÆC
  • Engineering units: PSI, in H2O (4¡ÆC), in H2O (20¡ÆC), in H2O (60¡ÆC), ft H2O (4¡ÆC), ft H2O (20¡ÆC)
  • Engineering units: cm H2O (4¡ÆC), cm H2O (20¡ÆC), m H2O (4¡ÆC), m H2O (20¡ÆC), BAR, Kg/cm2, kPa, mPa, mm Hg, m Hg
  • Communications through an RS232 port for real time data transfer to a PC or printer
  • Dual Range — ideal for custody transfer and mass flow applications
  • % Error function automatically calculates transmitter error during calibration
  • Integral 24 VDC power supply to power various devices under test
  • MIN/MAX storage and retrieval
  • Class I Division I Group C & D Certification pending
  • Pressure switch test feature
 
SPECIFICATIONS

Pressure

Ranges -1 to 5.000 PSI (0-135" H2O)
-5 to 30.000 PSI (0-800" H2O)
-5 to 100.00 PSI
-12 to 300.00 PSI
-12 to 300.00 PSI
Accuracy
5 PSI 0.05% of reading ¡¾0.001 PSI
30 PSI 0.05% of reading ¡¾0.002 PSI
100 PSI 0.05% of reading ¡¾0.02 PSI
300 PSI 0.05% of reading ¡¾0.02 PSI
3000 PSI 0.05% of reading ¡¾0.2 PSI
Vacuum 0.5PSI, all ranges
Electrical
Ranges 0 to 24.000 mA
0 to 10.000 V
Accuracy ¡¾0.025% of reading ¡¾2 LSD; 18¡ÆC to 28¡ÆC
Input Protection 1/8 A Fuse
Environmental
Operating Temp 0¡ÆC to 50¡ÆC
Storage Temp 20¡ÆC to 60¡ÆC
Stability ¡¾ .005% F.S./¡ÆC for both pressure and electrical for temperatures outside of 23¡ÆC ¡¾5¡ÆC
Media Any gases/liquids compatible with 316SS and nickel plated brass
Power 4 AA Alkaline Cells or 4 AA Ni-Cd Cells, Optional AC Adaptor, Ni-Cd Charger Available
Size 7.5 H (without boot) x 4.0 W x 1.5 D

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
ML200101   PPC-3300   Dual range pressure calibrator with .05% of reading accuracy   Yes   4,309,200
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ