ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¾Ð·Â Pressure

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
AS130200 Deadweight tester
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:AS130200
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Ashcroft deadweight testers provide an easy means of precisely generating pressure an accuracy
Ashcroft deadweight testers provide an easy means of precisely generating pressure to an accuracy of 0.1% of reading. 1305 units are available for operating ranges up to 10,000 psi. They are ideal in use of calibrating, setting, testing, and repairing pressure measurement and control devices. Each unit is traceable to the National Institute of Standards and Technology assuring instrument accuracy.
These pressure systems are designed to be field portable. A single carrying case holds the pressure generation pump as well as the necessary tools and accessories. A second box contains the weights used for pressure generation (10,000 units require 2 boxes of weights).
Ashcroft deadweight testers qualify as primary standards for pressure calibration. The pump is a two-stage hydraulic pressure generator. A built-in shuttle valve allows for rapid pressure increase at low pressures. The rate of increase, at pump cycle, can be reduced at higher pressures in order to minimize resistance. This is accomplished by simply repositioning the two position shuttle valve. With the shuttle valve in the high pressure position, increasing pressure even when near the 10,000 psi upper limit can be quickly and easily accomplished. Final, precise adjustment is accomplished through the use of an integral vernier adjustment knob.
The unit is provided with two piston cylinder assemblies: A low pressure piston for pressure ranges from 15 to 2000 psi and a high pressure unit for pressures from 75 to 10,000 psi. The high pressure piston has an area of 1/80th of a square inch while the low pressure piston has an area of 1/16th of a square inch. Weights are provided for pressure increments of 5, 10, 20, 25, 40, 50, 100, 200, and 500 psi (depending on piston in use). An optional 1 psi incremental weight is also available. Ashcroft testers can be used anywhere within their operational range without any change in accuracy. The same weights are used with both piston and cylinder assemblies.
The units are available for psi, bar, kg/cm2 and kPa ranges. Each unit comes complete with a hand jack set (for removal of pointers on gauges being calibrated), spare O-rings and all tools, accessories and fittings required for normal use.
 
Features
  • Accuracy of 0.1% of reading
  • Operating pressure of 15 psi to 10,000 psi (100 kPa to 70,000 kPa)
  • Operating media 1305D-SAE 20 weight automotive or machine oil 1305DH- Phosphate based or glycol fluids
  • Traceable to NIST
  • O-Ring material 1305D-Buna-N (D series) 1305DH- Ethylene propylene (DH series)
  • Stainless steel piston and cylinder material
  • Non-metallic die-cast zinc weight material
  • Reservoir volume approximately 1.5 pints (0.7 liter)
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AS130200   1305D-10   PRECISION DEAD WEIGHT TESTER   Yes   6,469,200
Low Pressure Range:   15-200psi
High Pressure Range:   75-1000psi
AS130201   1305D-20   PRECISION DEAD WEIGHT TESTER   Yes   6,966,000
Low Pressure Range:   15-400psi
High Pressure Range:   75-2000psi
AS130202   1305D-30   PRECISION DEAD WEIGHT TESTER   Yes   7,117,200 
Low Pressure Range:   15-600psi
High Pressure Range:   75-3000psi
AS130203   1305D-50   PRECISION DEAD WEIGHT TESTER   Yes   7,333,200 
Low Pressure Range:   15-1000psi
High Pressure Range:   75-5000psi
AS130204   1305D-100   PRECISION DEAD WEIGHT TESTER   Yes   8,985,600 
Low Pressure Range:   15-2000psi
High Pressure Range:   75-10,000psi
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ